Ashley Gas Stove Owner’s Manual
- June 7, 2024
- Ashley
Table of Contents
- IMPORTANT INFORMATION
- INSTALLATION CHECKLIST
- CUSTOMER SERVICE
- SAFETY INFORMATION
- PRODUCT FEATURES
- GETTING STARTED
- CLEARANCES & HEIGHT REQUIREMENTS
- INSTALLATION
- ELECTRICAL WIRING (MILLIVOLT)
- LOG PLACEMENT
- **OPERATION
- HOW TO ORDER REPAIR PARTS
- TROUBLESHOOTING
- REPLACEMENT PARTS
- REPLACEMENT PARTS
- SERVICE RECORD
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Owner’s Instruction and Operation Manual
Model Number:
AGC500VF
Control #:4002719
Certified for installations in the USA
Approved for installation in mobile homes
All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary. 852404G-1803K
Save These Instructions In A Safe Place For Future Reference.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency, or gas supplier.
Please read this manual BEFORE installing and operating this unit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which is
known to the State of California to cause cancer, birth defects, and/or other
reproductive harm. For more information, go to
www.P65warnings.ca.gov
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE
IMPORTANT INFORMATION
CODES
Adhere to all local codes or, in their absence, the latest edition of NFPA54.
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE
APPLIANCE.
IMPORTANT:
READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE STARTING INSTALLATION.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN A POSSIBLE FIRE HAZARD AND
WILL VOID THE WARRANTY.
WARNING:
- ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.
- IMPROPER INSTALLATION OR USE OF THE HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OR CARBON MONOXIDE POISONING.
- DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE STOVE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS.
- DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT, OR OTHER ACCESSORY, NOT APPROVED FOR USE WITH THIS HEATER WHERE APPLICABLE.
Note: Register your product online at www.usstove.com or download the free app today. This app is available only on the App Store for iPhone and iPad. Search US Stove. Save your receipt with your records for any claims.
WARNING: FIRE, EXPLOSION, AND ASPHYXIATION HAZARD
- IMPROPER ADJUSTMENT, ALTERATION, SERVICE, MAINTENANCE, OR INSTALLATION OF THIS HEATER OR ITS CONTROLS CAN CAUSE DEATH OR SERIOUS INJURY.
- READ AND FOLLOW INSTRUCTIONS AND PRECAUTIONS IN THE USER’S INFORMATION MANUAL PROVIDED WITH THIS HEATER.
- DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE STOVE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS.
- DO NOT USE A BLOWER INSERT, HEAT EXCHANGER INSERT, OR OTHER ACCESSORY, NOT APPROVED FOR USE WITH THIS HEATER WHERE APPLICABLE.
IMPORTANT:
READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO
ASSEMBLE, OPERATE, OR SERVICE THIS APPLIANCE. IMPROPER USE OF THESE LOGS CAN
CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE
POISONING.
IMPORTANT:
VENT-FREE HEATERS ADD MOISTURE TO THE AIR. ALTHOUGH THIS IS BENEFICIAL,
INSTALLING THIS HEATER INTO ROOMS WITHOUT ADEQUATE VENTILATION MAY CAUSE
MILDEW TO FORM FROM TOO MUCH MOISTURE.
For Customer Service, please call:
1-800-750-2723 Ext 5050 or;
Text to 423-301-5624 or;
Email us at:
customerservice@usstove.com
INSTALLATION CHECKLIST
Your Gas Stove should be installed by a qualified installer only. An NFI qualified Installer can be found at www.nficertified.org/public/find-an-nfi- pro/
CUSTOMER SERVICE
1-800-750-2723 ext 5050
Text to 423-301-5624
Email to: Customerservice@usstove.com
COMMISSIONING CHECKLIST
This Checklist is to be completed in full by the qualified person who installs
this unit. Keep this page for future reference.
Failure to install and commission according to the manufacturer’s instructions
and complete this checklist will invalidate the warranty.
Please Print
Customer Name: | I Telephone Number: |
---|
Address:
Model:
Serial Number’| | | | | | | | | | | | | | | | | | | | | | | | | | |
Installation Company Name:| Phone Number:
Installation Technician’s Name| License Number:
DESCRIPTION OF WORK
Location of installed appliance:
Venting System: New Venting System Yes No If yes, Brand
If no, Date of inspection of existing venting system:
COMMISSIONING
Confirm Hearth Pad Installation as per Installation Instructions …………………………..
Confirm proper placement of internal parts …………………………………………………………..
Check soundness of door gasket and door seals ……………………………………………………
Confirm clearances to combustibles as per installation instructions in this
manual.
Check the operations of the air controls ………………………………………………………………….
Confirm the venting system is secure and sealed ……………………………………………………..
Confirm the stove starts and operates properly …………………………………………………………
Check to ensure a CO alarm is installed as per local building codes and is
functional ….
Explain the safe operation, proper fuel usage, cleaning, and routine
maintenance requirements …
Declaration of Completion: As the qualified person responsible for the work
described above, I confirm that the appliance as associated work has been
installed as per the manufacturer’s instructions and following any applicable
building and installation codes.
Signed: __Print Name:
__ Date:
Home Owner: RETAIN THIS INFORMATION FOR FUTURE REFERENCE
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
NOTE REGARDING VENTED PRODUCTS
Flex line installation must not exceed 36 inches and must have a T shutoff
valve. Any residence with a direct vent product must have a CO detector
installed in the residence. Installation of the fireplace or vented gas log in
the State of Massachusetts requires the damper to be permanently removed or
welded in the fully open position. In addition,
neither a naturally vented gas log nor a vent-free product may be installed in
a bedroom or bathroom in the State of Massachusetts. All gas fitting and
installation of this heater shall only be done by a licensed gas fitter or
licensed plumber. For all sidewall, horizontally vented gas fueled equipment
installed in every dwelling, building, or structure used in whole or in part
for residential purposes, including those owned or operated by the
Commonwealth and where the sidewall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but
not limited to decks and porches, the following requirements shall be
satisfied:
INSTALLATION OF CARBON MONOXIDE DETECTORS
At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gas fitter shall observe that a hard-
wired carbon monoxide detector with an alarm is installed on each additional
level of the dwelling, building, or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the responsibility of the
property owner to secure the services of qualified licensed professionals for
the installation of hard-wired carbon monoxide detectors. In the the event
that the side wall horizontally vented gas fueled equipment is installed in a
crawl space or an attic, the hard-wired carbon monoxide detector with alarm
and battery, back-up may be installed on the next adjacent floor level. In the
event that the requirements of this subdivision can not be met at the time of
completion of installation, the owner shall have a period of thirty (30) days
to comply with the above requirements; provided, however, that during said
thirty (30) day period, a battery-operated carbon monoxide detector with an
alarm shall be installed.
APPROVED CARBON MONOXIDE DETECTORS
Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and ANSI/UL 2034 listed and IAS
certified.
SIGNAGE
A metal or plastic identification plate shall be permanently mounted to the
exterior of the building at a minimum height of eight (8) feet above grade
directly in line with the exhaust vent terminal for the horizontally vented
gas-fueled heating appliance or equipment. The sign shall read, in print size
no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW, KEEP CLEAR
OF ALL OBSTRUCTIONS”.
INSPECTION
The state or local gas inspector of the side wall horizontally vented gas
fueled equipment shall not approve the installation unless, upon inspection,
the inspector observes carbon monoxide detectors and signage installed in
accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
Exemptions
The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
- The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
- Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
GAS EQUIPMENT VENTING SYSTEM PROVIDED
When the manufacturer of Product Approved side wall horizontally vented gas
equipment provides a venting system design or venting system components with
the equipment, the instructions provided by the manufacturer for installation
of the equipment and the venting system shall include:
- Detailed instructions for the installation of the venting system design or the venting system components; and
- A complete parts list for the venting system design or venting system.
GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED
When the manufacturer of a Product Approved side wall horizontally vented gas
fueled equipment does not provide the parts for venting the flue gases, but
identifies “special venting systems”, the following requirements shall be
satisfied by the manufacturer:
- The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
- The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
SAFETY INFORMATION
-
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
-
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
-
Young children should be carefully supervised when they are in the same room with the appliance.
-
Do not place clothing or other flammable material on or near the appliance.
-
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater.
-
Installation and repair should be done by a qualified service person.
-
To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways be kept clean.
-
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness, and/or nausea. If you have these signs, obtain fresh air immediately. Has the heater been serviced as it may not be operating properly?
-
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54.
-
This unit complies with the latest edition of ANSI Z21.11.2, Unvented Heaters.
-
Do not install a heater in a bathroom or bedroom unless approved for bedroom use.
-
Correct installation of the ceramic fiber logs, proper location of the heater, and annual cleaning is necessary to avoid potential problems with sooting. Sooting, resulting
from improper installation or operation, can settle on surfaces outside the fireplace. See log placement instructions for proper installation. -
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside the burn area of the firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
-
Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent-free appliances will not filter or clean soot produced by these types of products. In addition, the smoke and/or aromatics (scents) may be returned in the vent-free appliance which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent-free appliance is in operation.
-
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided.
-
This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes.
-
An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom.
-
Keep room area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
-
Unvented gas heaters are supplemental zone heaters. They are not intended to be a primary heating appliance.
-
Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.
-
During manufacturing, fabricating, and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smell as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last two to three hours with the burner at the highest setting. Provide
maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use. -
Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced by 4% for every 1,000 feet above sea level.
Refer to the National Fuel Gas Code. -
The appliance and its appliance’s main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).
-
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).
-
Do not use this room heater if any part has been underwater. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been underwater.
-
Never burn solid fuels in an unvented room heater, fireplace, or stove.
-
Do not set kettles or humidifying devices on top of the stove.
-
The stove door/screen must be closed when the appliance is operating. The screen shall have openings for the induction of combustion air.
PRODUCT FEATURES
Gas Pressures
| Natural| propane(LP)
Regulator Pressure| 3.5″ w.c.| 10.0″ w.c.
Pilot Regulator| 3.5″ w.c.| n/a
Max. Gas Inlet Pressure| 10.5. w.c.| 13.0″ w.c.
Min. Gas Inlet Pressure| 5.0″ w.c.| 11.0″ w.c.
Fuel| Control| Max. Input
BTU/h| Min. Input
BTU/h
---|---|---|---
Nat.| Millivolt| 32,000| 23,000
LP| Millivolt| 32,000| 23,000
. WARNING:
THIS APPLIANCE IS EQUIPPED FOR (NATURAL OR PROPANE) GAS. FIELD CONVERSION IS
NOT PERMITTED.
NOTE: An external regulator is required to reduce supply pressure to a
maximum of 10.5” w.c. on Natural Gas systems operating at higher pressure.
NOTE: An external regulator is required to reduce supply pressure to a
maximum of 13.0” w.c. for LP systems.
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches.
Millivolt control has four (4) positions:
OFF| All gas to the burner is shut off at the valve.
IGN| Valve position to light/maintain a standing pilot.
ON| Valve position to turn burners on/off.
LOW/
HI| Variable position to control flame height (heat output). Both front and
rear burners are in operation to provide a realistic glow and yellow flame.
PILOT /ODS
The gas log heater is fitted with a specially designed safety pilot (ODS
assembly) light which senses the amount of oxygen available in the room and
shuts the gas log heater off if the oxygen level begins to drop below a
satisfactory level. The pilot can only be relit when adequate fresh air is
available.
DIMENSIONS
GETTING STARTED
CAUTION:
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENT SKIN
IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE — HANDLE WITH CARE.
MAKE SURE YOU HAVE RECEIVED ALL PARTS
Check your packing list to verify that all listed parts have been received.
You should have the following:
- Cast Iron Stove with Burner Assembly
- Installation/Operating Instructions
- Ceramic Fiber Logs
Carefully inspect the contents for shipping damage.
If any parts are missing or damaged, immediately inform the dealer from whom you purchased the appliance. Do not attempt to install any part of the appliance unless you have all parts in good condition.
WHAT THE GAS TECHNICIAN WILL NEED FOR INSTALLATION
You must have the following items available before proceeding with
installation:
- External regulator (for Propane/LPG) or high-pressure natural gas (1 to 2 psi system)
- Piping which complies with local codes
- Sediment trap (recommended)
- Pipe wrench
- Pipe sealant approved for use with propane/LPG (resistant to sulfur compounds)
- Manual shutoff valve
- Tee joint
- Screwdrivers
WARNING:
DO NOT INSTALL THE HEATER …
- WHERE CURTAINS, FURNITURE, CLOTHING, OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42” FROM THE HEATER.
- IN HIGH TRAFFIC AREAS.
- IN WINDY OR DRAFTY AREAS.
WARNING:
IF THE AREA IN WHICH THE HEATER MAY BE OPERATED DOES NOT MEET THE REQUIRED
VOLUME FOR INDOOR COMBUSTION AIR, COMBUSTION AND VENTILATION AIR SHALL BE
PROVIDED BY ONE OF THE METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE,
ANSI Z223.1/NFPA 54, THE INTERNATIONAL FUEL GAS CODE OR APPLICABLE LOCAL
CODES.
CLEARANCES & HEIGHT REQUIREMENTS
WARNING:
THE DIMENSIONS SHOWN ARE MINIMUM CLEARANCES TO MAINTAIN IN INSTALLING THIS
HEATER. LEFT AND RIGHT CLEARANCES ARE DETERMINED WHEN FACING THE FRONT OF THE
HEATER. FOLLOW THESE INSTRUCTIONS CAREFULLY TO ENSURE SAFE INSTALLATION.
FAILURE TO FOLLOW INSTRUCTIONS EXACTLY CAN CREATE A FIRE HAZARD. THE APPLIANCE
CANNOT BE INSTALLED ON A CARPET,
TILE OR OTHER COMBUSTIBLE MATERIAL.
THE APPLIANCE SHALL BE INSTALLED ON A NON-COMBUSTIBLE MATERIAL PANEL EXTENDING
THE FULL WIDTH AND DEPTH OF
THE APPLIANCE.
Q | Min Ceiling From Floor | 72″ |
---|---|---|
o3 | Mantel Clearance From Top Of Unit | Max. Protrusion |
C | Min. Height | 18″ |
0 | Side Measured From | Right |
E | Left | 2″ |
F | Rear Measured From Back | 1″ |
G | Corner Measured From Top Corners | 1/2″ |
Alcove Minimum Dimensions
Height From
Hearth| Width| Depth
A| B| C
52″| 34″| 36″
NOTE: Maintain minimum side and back clearances when placing the stove in an
alcove.
ATTENTION:
MAINTAIN LISTED CLEARANCES FOR ANY REQUIRED SERVICING AND FOR PROPER OPERATION
OF THIS APPLIANCE.
INSTALLATION
CAUTION!
THE APPLIANCE IS VERY HEAVY. THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY
SUGGESTED. PLEASE USE PROPER LIFTING TECHNIQUES WHEN POSITIONING THE APPLIANCE
FOR ASSEMBLY AND INSTALLATION.
-
Remove the two (2) straps, and open the wrapping. Slide the bag to the bottom of the unit.
-
Lift up on the ash lip. Pivot it back and down to open the control door.
-
Lift up on the front of the stove. Pivot the bottom out towards you. Pull down to remove the front. Note: When handling the stove be careful not to damage the porcelain finish of the unit.
-
Remove the two screws located at the bottom of the screen as shown. Lift up and back on the screen to remove.
-
Remove the log box from inside the unit. Lift the unit off the pallet. NOTE: Make sure to lift the unit up high enough to clear the upright supports the unit is sitting on.
-
Reverse steps 2-4 to reinstall the screen and front of the stove.
CAUTION:
THE APPLIANCE IS VERY HEAVY. THE ASSISTANCE FROM A SECOND PERSON IS STRONGLY
SUGGESTED. PLEASE USE PROPER LIFTING TECHNIQUES WHEN POSITIONING THE APPLIANCE
FOR ASSEMBLY AND INSTALLATION.
WARNING:
USE NEW BLACK IRON OR STEEL PIPE.
INTERNALLY TINNED COPPER OR COPPER TUBING CAN BE USED PER THE NATIONAL FUEL
CODE, SECTION 2.6.3, PROVIDING GAS MEETS HYDROGEN SULFIDE LIMITS, AND WHERE
PERMITTED BY LOCAL CODES. A GAS PIPING SYSTEM MUST BE SIZED TO PROVIDE MINIMUM
INLET PRESSURE (LISTED ON THE DATA PLATE) AT THE MAXIMUM FLOW RATE (BTU/HR).
UNDUE PRESSURE LOSS WILL OCCUR IF THE PIPE IS TOO SMALL.
A MANUAL SHUTOFF VALVE MUST BE INSTALLED UPSTREAM OF THE APPLIANCE.
UNION TEE AND PLUGGED 1/8” NPT PRESSURE TAPPING POINT SHOULD BE INSTALLED
UPSTREAM OF THE APPLIANCE. A SEDIMENT TRAP SHOULD BE INSTALLED UPSTREAM TO
PREVENT MOISTURE AND CONTAMINANTS FROM PASSING THROUGH THE PIPE TO APPLIANCE
CONTROLS AND BURNERS.
FAILURE TO DO SO COULD PREVENT THE APPLIANCE FROM OPERATING RELIABLE.
NOTICE : A qualified gas appliance installer must connect the heater to
the gas supply. Consult all local codes.
IMPORTANT: Hold the heater valve firmly with a wrench to prevent movement when
connecting to the inlet pipe. Always use an external regulator for all
propane/LPG heaters and high pressure one to two-pound systems only, to reduce
the supply tank pressure to a maximum of 13” w. This is in addition to the
internal regulator in the heater valve.
CHECK GAS TYPE : The gas supply must be the same as stated on the
heater’s rating plate. If the gas supply is different, DO NOT INSTALL THE
HEATER.
Contact your dealer for the correct model.
ELECTRICAL WIRING (MILLIVOLT)
The millivolt valve is a self-powered combination gas control THAT DOES NOT REQUIRE 110V AC TO OPERATE.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER
SERVICING.
CONNECT OPTIONAL WALL SWITCH
- Use 18 AWG, two-wire cable, 15 feet maximum length.
- At one end of the cable, connect both wires to the wall switch. At the other end, connect one wire to TP/TH and one wire to TH, or connect the wall switch to the two male (0.25”) terminals on the left side of the unit.
CHECK SYSTEM OPERATION
The millivolt system and individual components may be checked with a millivolt
meter having a 0-1000 mV range. Conduct each check shown in chart below by
connection meter test leads to terminals as indicated.
A. Complete Millivolt System Check (“A” Reading – Thermostat contacts closed –
Control Knob “ON” – Main burner should turn on)
- If the reading is more than 100 millivolts and the automatic valve still does not come on, replace the control.
- If the closed-circuit reading (“A” reading) is less than 100 millivolts, determine cause for low reading, proceed to section B below.
ELECTRICAL WIRING (MILLIVOLT)
B. Thermopile Output Reading Check (“B” Reading
– Thermostat contacts open – Main burner off)
- Check gas pressure on the unit. If gas pressure is within minimum and maximum on the data plate, then check pilot voltage, 325 millivolts minimum.
If the minimum millivolt reading is not obtainable, replace the pilot.
Check
Test| To Test| Connect
Meter
Leads to
Terminals| Switch or
Thermostat
Contacts| Meter
Reading
Should
Be
---|---|---|---|---
A| Complete
System| 2 & 3| Closed| Closed
B| Thermopile| 1 & 2| Open| Open
LOG PLACEMENT
WARNING:
POSITIONING OF THE LOGS IS CRITICAL TO THE SAFE AND CLEAN OPERATION OF THIS
HEATER.
SOOTING AND OTHER PROBLEMS MAY RESULT IF THE LOGS ARE NOT PROPERLY AND FIRMLY
POSITIONED IN THE APPLIANCE. NEVER ADD ADDITIONAL LOGOS OR EMBELLISHMENTS SUCH
AS PINE CONES, VERMICULITE, OR ROCK WOOL TO THE HEATER. ONLY USE THE LOGS
SUPPLIED WITH THE UNIT. FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THE
DIAGRAMS BELOW OR TO USE ONLY PARTS SPECIFICALLY APPROVED FOR THIS HEATER MAY
RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.
Before you begin – This unit is supplied with five ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers. NOTE: When placing logs DO NOT cover the burner ports.
-
To install the backlog (#1), position on rear log support bracket and then press down over studs.
-
Install left bottom log (#2) on left log support bracket in front of backlog.
-
Install right bottom log (#3) on right log support bracket in front of backlog.
-
Install top left log (#4) on top of the left bottom log.
-
Install top right log (#5) on top of the right bottom Bottom log.
CAUTION:
DURING THE INITIAL OPERATION OF THE NEW HEATER, BURNING LOGS WILL GIVE OFF
A PAPER BURNING SMELL AND ORANGE FLAMES WILL BE PRESENT. SIMPLY OPEN THE
WINDOWS FOR A FEW HOURS TO VENT THE ODOR.
GLOWING WOOL PLACEMENT
Provided with your log set is a package of Glowing members (rock wool). Break
up the glowing wool into small dime-sized pieces or for a finer finish use a
metal wire brush. Place it over the small holes (pores) located on the burner
pan. Cover the entire section of holes (ports).*Replacement of loose (Glowing
Wool) must be purchased from the original manufacturer and application of
excess loose material may adversely affect the performance of the heater.
NOTE: Wash your hands immediately after coming in contact with wool material.
In some cases, the wool can cause slight itching or burn, avoid any contact
with eyes.
WARNING:
Flames from the pilot, front, and rear burner should be visually checked as
soon as the heater is installed.
In addition, periodically check the flames visually during operation.
FLAME APPEARANCE
Flames from the pilot, front and rear burner should be visually checked as
soon as the heater is installed. In addition, periodically check the flames
visually during operation.
PILOT FLAME
The pilot flame must always be present when the heater is in operation. It
should just touch the top of the thermocouple tip for natural. Refer to the
figure below for the correct pilot flame.
If the pilot flame does not touch the thermocouple, then the burners cannot
function reliably. Refer to the figure below for the incorrect shape of the
pilot flame.
MILLIVOLT CONTROL
BURNER FLAME
In normal operation at full rate after 15 minutes, the following flame
appearances should be observed:
The left and right rear flames should be yellow and extend 1”- 2” above middle
logs. The yellow flames should not contact the logs. There should be glowing
embers on the front surface of the middle log. NOTE The flames and embers will
be an opaque orange color during the burn-off time.
**OPERATION
**
OPERATING INSTRUCTIONS
Avoid any drafts that alter burner flame patterns. Do not allow fans to blow
directly into the stove. Do not place a blower inside the burn area of the
stove. Ceiling fans may create drafts that alter flame patterns. Sooting and
improper burning will result. During manufacturing, fabricating, and shipping,
various components of this appliance are treated with certain oils, films, or
bonding agents. These chemicals are not harmful, but may produce annoying
smoke and smell as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This is a
normal and temporary occurrence. The initial breaking operation should last
two to three hours with the burner at the highest setting. Provide maximum
ventilation by opening windows or doors to allow odors to dissipate. Any odors
remaining after this initial break-in will be slight and will disappear with
continued use.
For Your Safety Read Before Lighting
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. This appliance is equipped with an ignition device that automatically
lights the pilot. If the piezo is not working properly, refer to Match
Lighting instructions.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
- Turn off all gas to the appliance.
- Open windows.
- Do not attempt to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or turn by hand, don’t try to repair it.
Call a qualified service technician. Force or attempted repair may result in a
fire or explosion.
D. Do not use this appliance if any part of it has been underwater.
Immediately call a qualified service technician to inspect the appliance and
to replace any part of the control system and any gas control that has been
underwater.
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
-
STOP! Read All Labels.
-
Make sure the manual shutoff valve is fully open.
-
This heater is equipped with an ignition device (piezo) which automatically lights the pilot. If the pilot will not light using the piezo ignitor refer to the manual lighting procedure.
-
Turn gas control knob clockwise to the “OFF” position, set the thermostat to the lowest setting, and turn the ON/OFF switch to the “OFF” position.
-
Wait five (5) five minutes to clear out any gas.
Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information label. If you don’t smell gas, go to the next step. -
From the “OFF” position, turn the gas control knob counterclockwise to the “IGN” position.
Push in the control knob for (5) five seconds. -
With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
-
Continue pushing the control knob in for a further (60) sixty seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.
-
Turn the gas control knob counterclockwise to the “ON” position.
-
After the pilot has been lit for one minute, the burners can be turned on. Turn the On/Off switch to the “ON” position and adjust the thermostat to the desired setting.
-
If the heater will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your supplier.
-
Wait (30) thirty seconds before readjusting the heater when the control knob has been turned down to a lower setting.
TO TURN OFF GAS TO HEATER
- Turn gas control knob clockwise to the “OFF” position. Do not force.
- Turn On/Off switch to the “OFF” position and/ or set the thermostat (if present) to the lowest setting.
- If applicable: Turn off all electric power to the appliance.
MANUAL LIGHTING INSTRUCTIONS
- Open stove door. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
- Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo button, light a match and hold the flame to the end of the pilot and ignite the pilot.
- After control knob has been released and pilot stays lit, reinstall any items that were removed for pilot access.
- Call a qualified service technician for repair or replacement of the piezo ignitor.
CLEANING AND SERVICING
WARNING:
TURN OFF THE HEATER AND ALLOW TO COOL BEFORE CLEANING. DISCONNECT THE
ELECTRICAL POWER BEFORE CLEANING OR SERVICING.
Annual inspection and cleaning by your dealer or qualified service technician
is recommended to prevent malfunction and/or sooting. Remove logs, handle
carefully by holding gently at each end.
Gloves are recommended to prevent skin irritation from ceramic fibers. If skin
becomes irritated, wash gently with soap and water. Refer to manual for
correct log placement.
Periodic Cleaning – See parts diagram for location of items discussed below.
-
Do not use cleaning fluid to clean logs or any part of the heater.
-
Brush logs with a soft bristle brush or vacuum with a brush attachment.
-
Vacuum loose particles and dust from the front and rear burners, control, piezo covers and grate weldment.
-
Inspect and clean the burner air intake holes.
Remove lint or particles with a vacuum, brush, or some pipe cleaners. Failure to keep air intake holes clean will result in sooting and poor combustion. -
The external case should be dusted and wiped with a moist cloth.
Annual Cleaning/Inspection – Refer to the parts diagram for location of items.
- Inspect and clean burner air intake holes. Remove lint or particles with a vacuum, brush or some pipe cleaners. Failure to keep the air intake holes clean will result in sooting and poor combustion.
- Inspect and clean all burner ports.
- Inspect ODS pilot for operation and accumulation of lint at air intake holes.
- Verify flame pattern and log placement for proper operation.
- Verify smooth and responsive ignition of the main burner and rear burner.
HOW TO ORDER REPAIR PARTS
For Parts Assistance
Call:800-750-2723 Ext 5051 or Email:
parts@usstove.com
The information in this owner’s manual is specific to your unit. When ordering
replacement parts the information in this manual will help to ensure the
correct items are ordered. Before contacting customer service write down the
model number and the serial number of this unit. That information can be found
on the certification label attached to the back of the unit. Other information
that may be needed would be the part number and part description of the
item(s) in question. Part numbers and descriptions can be found in the “Repair
Parts” section of this manual. Once this information has been gathered you can
contact customer service by phone at
1-800-750-2723 Ext 5051 or Email
parts@usstove.com.
Model Information
Model Number|
Serial Number|
TROUBLESHOOTING
WARNING : TURN THE APPLIANCE “OFF” AND ALLOW TO COOL BEFORE SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND REPAIR THE HEATER.
PROBLEM | POSSIBLE CAUSE | REMEDY |
---|---|---|
When the ignitor button is pressed, there is no spark at ODS/pilot. | Ignitor | |
electrode positioned wrong. | Replace ignitor. | |
Ignitor electrode is broken. | Replace ignitor. | |
Ignitor electrode not connected to the ignitor cable. | Reconnect ignitor |
cable.
Ignitor cable pinched or wet.| Free ignitor cable if pinched by any metal or
tubing. Keep ignitor cable dry.
Broken ignitor cable.| Replace ignitor cable.
Bad piezo ignitor.| Replace piezo ignitor.
Appliance produces unwanted odors.
etc.| Appliance burning vapors from paint, hair spray, glues,| Ventilate room.
Stop using odor causing products while heater is running.
Gas leak.| Locate and correct all leaks.
Initial burn off.| Ventilate room and turn unit on high until odor is gone.
Odor should be gone after 6 hours of continuous use.
Appliance shuts off during use.| Not enough fresh air is available for ODS/
pilot to operate.| Open window and/or door for ventilation.
Low line pressure.| Contact local gas company.
ODS/pilot is partially clogged.| Clean ODS/pilot.
Defective Thermopile.| Check pilot flame, check wire connections, check
output, should be 325 millivolts across TH/TP and TP Terminals with On/Off
switches Off.
Restrictions in incoming air flow.| Check for bottom riser on glass door,
sunken fireplace, excessive lava rock/cinders densely packed against grate.
Gas odor even when control knob is in OFF position.| Gas leak.| Locate and
correct all leaks.
Control valve defective.| Replace control valve.
ODS/pilot lights, but flame goes out when control knob is released.| Control
knob not fully pressed in.| Press in control knob fully.
Control knob not pressed in long enough.| fter ODS/pilot lights, keep control
knob A
pressed in for 30 seconds.
Manual shutoff valve not fully open.| Fully open manual shutoff valve.
Thermocouple connection loose at control valve.| Hand tighten thermocouple
connection until snug, then tighten 1/4 turn more.
Pilot flame not touching thermocouple, which allows thermocouple to cool,
causing pilot flame to go out. This problem could be caused by either low gas
pressure, or a dirty or partially clogged ODS/pilot.| Contact local gas
company. Clean pilot with vacuum cleaner.
Thermocouple damaged.| Replace thermocouple.
Control valve damaged.| Replace control valve.
Burner does not light after ODS/ pilot is lit.| Burner orifice is clogged.|
Clean orifice.
Burner orifice diameter is too small.| Replace burner orifice.
Inlet gas pressure is too low.| Contact qualified service person
Burner
backfires during combustion.| Manifold pressure is too low. Burner orifice is
clogged.| Contact local gas company.
Clean burner or replace burner orifice.
|
Slight smoke
or odor during initial operation.| Burner orifice is clogged or damaged.|
Clean burner or replace burner orifice.
Burner is damaged.| Replace burner.
Gas regulator defective.| Replace gas regulator.
Logs appear
to smoke after initial operation.| Vapors from paint or curing process of
logs.| Problem will stop after a few hours of operation. Run the heater with
the
damper open if you have one, or open a window for the first few hours.
Vapors or smoke continue after heater has run with damper or window open for
several hours.| Log heater is intended to be smokeless. Turn OFF heater and
call qualified service person.
Heater produces a whistling noise when burner is lit.| Turning control knob to
HIGH position when burner is cold.| Turn control knob to LOW position and let
warm up for a minute.
Air in gas line.| Operate burner until air is removed from line. Have gas line
checked by local gas company.
Dirty or partially clogged burner orifices.| Clean burner or replace burner
orifi
No gas to pilot.| LP-regulator shut down due to inlet pressure too high.|
Verify LP tank regulator is installed and set at 11″ to 13″ w.c. Replace
regulator on heater.
REPLACEMENT PARTS
REPLACEMENT PARTS
Key | Part # | Description | Qty |
---|---|---|---|
1 | 40861 | VF Grate | 1 |
2 | 40860 | VF Top | 1 |
3 | 40857 | Left Side | 1 |
4 | 40856 | Right Side | 1 |
5 | 27225 | Side Log Retainer | 2 |
6 | 27222 | Rear Log Support | 1 |
7 | C42373 | Rocker Switch | 1 |
8 | 892537. | Base Assembly | 1 |
9 | 892538. | Control Panel | 1 |
10 | 892538. | Control Cover | 1 |
11 | 40854 | Leg | 1 |
12 | 610120 | Front Screen Assy | 1 |
13 | 40859 | Ash Bar | 1 |
14 | 40858 | Control Cover | 1 |
15 | 40855 | Front | 1 |
16 | 89921 | ODS Pilot Assembly (NAT) | 1 |
89922 | ODS Pilot Assembly (LP) | 1 | |
17 | 81211-06 | Rear Burner | 1 |
18 | 81211-05 | Front Burner | 1 |
19 | 81211-12 | VF Valve Tube | 1 |
20 | 81202 | Control Valve (LP) | 1 |
81198 | Control Valve (NAT) | 1 | |
21 | 89761 | Piezo Ignitor | 1 |
22 | 81212. | On/Off Switch | 1 |
23 | 81211-14 | VF Front Burner Tube | 1 |
24 | 81211-11 | 5/16 Union Tee | 1 |
25 | 81211-13 | VF Rear Burner Tube | 1 |
26 | 81210-08 | Upper Burner Orifices (Nat) #47 | 1 |
27 | 81210-15 | Lower Burner Orifices (NAT) #47 | 1 |
28 | 81211-16 | Upper Burner Orifices (LP) #56 | 1 |
29 | 81211-17 | Lower Burner Orifices (LP) #55 | 1 |
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY COMPONENTS WILL VOID THE WARRANTY.
SERVICE RECORD
It is recommended that your heating system is serviced regularly and that the
appropriate Service Interval Record is completed.
SERVICE PROVIDER
Before completing the appropriate Service Record below, please ensure you have
carried out the service as described in the manufacturer’s instructions.
Always use the manufacturer’s specified spare part when replacement is
necessary.
Service 01
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 02
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 03
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 04
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 05
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 06
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 07
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
Service 08
Date: _
Engineer Name: ___
License No.: ____
Company: ____
Telephone No.:
Stove Inspected: __ Chimney Swept: __
Items Replaced: ___
NOTES ___