Unplug machine
-
Remove dirt tank by sliding the Lock ‘n Seal lever to the unlock position and pulling straight out
-
Empty dirt tank
-
Remove cyclone from upper tank by twisting to unlock and pull down
- Cyclone and screen can be separated for cleaning by pulling apart
- Both can be cleaned with water and mild detergent
- Allow to air dry completely before reinstalling in machine
-
On select models, twist the Dirt Tank Filter Frame to the left to remove the frame and Upper Tank Filter
- Wash the filter with water and a mild detergent
- Let it completely air dry before placing back in the machine
-
Pull out the filter tray located below the dirt tank and wash the pre-motor filter with water and a mild detergent
- Allow to air dry completely before placing back in the machine
-
Open the filter door on the back of machine and remove the post-motor filter
- Tap this filter against a waste bin to remove excess debris
-
Remove the upholstery hose from the back of the machine by twisting the top left corner to the left to unlock and pulling the hose up from the bottom
- Run a broom handle through the hose to remove any clogs
-
Remove the Lift Off pod from the base using the Grab and Go button
-
Recline the handle of the base and check the lower hose for clogs
- Run a broom handle through lower hose to clear any clogs
-
With the machine unplugged, turn the machine over so brush is facing up
-
Remove the 6 screws that hold on the Brush Access Plate
-
Check the brush and belt for damage
- The brush should easily spin by hand
- The belt should be intact
- If part is damaged, it will need to be replaced
-
If the machine continues to not suction, visit a BISSELL Authorized Service Center or Contact Us
-