  • Unplug vacuum

    • Recline handle to the floor and roll machine over to view brush roll and access plate

    • Take out the one screw for lower hose and remove plastic tube attached to clear tube

    • Take out the five (5) screws from the access plate for the brush

    • Lift up height roller assembly and lift lower hose, pulling it out of bottom of machine

    • Replace with new lower hose and reassemble height roller assembly, brush access plate and screw for lower hose