PowerForce® Helix™ Bagless Upright Vacuum replacing lower hose | Support

June 7, 2024
Bissell

  • Unplug vacuum

    • Recline handle to the floor and roll machine over to view brush roll and access plate

    • Take out the one screw for lower hose and remove plastic tube attached to clear tube

    • Take out the five (5) screws from the access plate for the brush

    • Lift up height roller assembly and lift lower hose, pulling it out of bottom of machine

    • Replace with new lower hose and reassemble height roller assembly, brush access plate and screw for lower hose

    • Recipient Email

Your Email

Your Name

Was this answer helpful?

Yes
No

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals