Unplug the machine
-
Remove the Brush Access Plate by unscrewing the 4 screws on bottom
- There are 2 screws in front and 2 behind the brush
- Remove the Brush Access Plate to access the brush and belt
-
Lift off the Brush Access Plate to access the brush and belt
-
To remove the brush and belt, lift the brush up and out of the machine
-
Inspect the brush and belt and replace if either are damaged
- The brush should spin freely by hand
- To test the brush, stand brush up on one end and turn bristles
- Brush should turn freely, if not it should be replaced
- Inspect belt, if damaged it should be replaced
-
To replace the belt, hook the belt over the metal motor pulley and over the brush between the belt guards
-
Replace the brush back into the machine, making sure the ends fit into their corresponding shaped slots
- The left will be circular, the right rectangular
-
Spin the brush by hand several times to center the belt
-
If the Brush still does not turn, visit a BISSELL Authorized Service Center or Contact Us