enkeeo SC2300i Inverter Generator User Manual

June 7, 2024
enkeeo

enkeeo SC2300i Inverter Generator User Manual
enkeeo SC2300i Inverter Generator

Thanks for choosing ENKEEO. This manual contains important information, for your safety and perfect experience, please read this manual carefully, and keep it for future reference.

Safety Instructions

WARNING!
Read and understand all safety precautions in this manual before operating. Failure to comply with instructions in this manual could result in personal injury and/or property damage.

FUEL IS HIGHLY FLAMMABLE AND POISONOUS

  • Always turn off the engine when refueling.

  • Never refuel while smoking or in the vicinity of an open flame.

  • Take care not to spill any fuel on the engine or muffler when refueling.

  • If you swallow any fuel, inhale fuel vapor, or allow any to get in your eye(s), see your doctor immediately.
    If any fuel spills on your skin or clothing, immediately wash with soap and water and change your clothes.

  • When operating or transporting the machine, be sure it is kept upright. If it tilts, fuel may leak from carburetor or fuel tank.

EXHAUST FUMES ARE POISONOUS

  • Never operate this product in a closed area or it may cause unconsciousness and death within a short time. Always operate this product in a well ventilated outdoor area.

ENGINE AND MUFFLER MAY BE HOT

  • When operate the generator, place it in a safe area away from pedestrians or children.
  • Avoid placing any flammable materials near the exhaust outlet during operation.
  • Keep the generator at least 1m(3 ft) from buildings or other equipment, or the product may overheat.
  • Do not operate the product with a dust cover, or other objects covering it.
  • When covering the generator, be sure to do so only after the engine and muffler have completely cooled down.
  • Be sure to carry the generator only by its carrying handles.
  • Do not place any obstacles on the generator.

TO PREVENT ELECTRIC SHOCK

  • Never operate the product in rain or snow.
  • Never touch the generator with wet hands or electrical shock can occur.

GROUNDING

  • Properly ground generator to prevent electric shock.
  • Connect the ground terminal of the generator to the ground electrode buried in the ground.

WARNING NOTES

  • Failure to properly ground the generator can result in electric shock.
  • Be sure to always comply with electric loads.

CONNECTION

  • Before the generator can be connected to a building’s electrical system, a license electrician must install an isolation (transfer) switch in the building’s main fuse box. The switch is the connection point for generator power and allows selection of generator or main line power to the building. This will prevent the generator from charging the main power line (back feeding) when the main power supply has failed or has been turned off for line maintenance. Also, generator and building electrical system damage can occur when normal operating power returns if unit is used without an auto-switch.
  • Always use proper approved electrical cords. Be sure to comply with all electric codes.
  • Do not use electrical cords that are worn or damaged.
  • Always use GFCI (ground fault circuit interruptor) for damp locations.
  • Always use proper approved transfer switch to isolated generator from the electric panel.

Controls and Features

Generator
Product overview

  1. Muffler
  2. Carrying Handle
  3. Vented Gas Cap
  4. Recoil Starter
  5. Control Pane
  6. Fuel Gauge
  7. Exhaust and Spark Arrester
  8. Oil Filler Cap
  9. Multi-Switch

Control Panel

  1. Economy Throttle
  2. Low Oil Alarm
  3. Overload Alarm
  4. Output Indicator
  5. DC Circuit Breaker
  6. 12V DC Output
  7. Parallel Output
  8. 5V 1A DC USB
  9. Ground Terminal
  10. 120V L5-30R
  11. 120V 5-20R

Control Functions

  1. ECO THROTTLE
    Control Functions inductions
    When the Throttle switch is in the “ON” position, the throttle controls the engine speed according to the connected electrical load. The results are better fuel consumption and less noise. When the switch is in the “OFF” position, the engine runs at 4,500 rpm regardless of the electrical load.
    Note: The Throttle must be “OFF” when using electrical devices that require a large starting current, such as a compressor, pump, or refrigerator

  2. LED Indicators
    The LED Indicators assist in communicating status and functions of the unit
    Output Indicator (Green)
    Control Functions inductions
    The Output Indicator comes on when the engine starts and produces power.
    Overload Alarm (Red)
    The Overload Alarm comes on when a connected device requires more power than the generator is able to produce. The Output Indicator will go off and the Overload Alarm will stay on, but the engine will continue to run.
    Low Oil Alert (Red)
    When the engine oil falls below the required level, the Low Oil Alert will come on and the engine will stop automatically. The engine will not restart until oil is added to bring it up to the appropriate level.

  3. 12V 8A DC
    DC
    The 12V 8A DC Output is provided for battery charging. Follow instructions in the owner’s manual for the battery charging procedures.

  4. 8A DC Circuit Breaker
    Control Functions inductions

    The 8A DC Circuit Breaker turns off automatically if the current exceeds 8A. If the circuit breaker turns “OFF”, you will need to push it to turn it “ON” again.

  5. Parallel Output
    Two generators can be connected to increase output. Put parallel wire into the socket first, then start the two greater wattage as the normal process.
    Note: Put the connection wire into the right sockets.

  6. Multi-Switch
    Control Functions inductions

    The Multi-Switch control fuel valve, choke and engine switch.
    When starting the generator, rotate the Multi-Switch counter clockwise from STOP to START position, then pull recoil cord quickly to start. After started, rotate the switch to RUN position.
    Note: To shut off generator, rotate Multi-Switch clockwise to STOP position and hold until generator turns off.

  7. 5V 1A DC USB
    Control Functions inductions

  8. 120V AC Outlet
    Control Functions inductions

    The Outlet is used to power 120V Single Phase 60Hz requiring up to 1600W continuous power. 120V AC twist lock receptacle (NAME LR-30R) may be used to supply electrical power when parallel connection.
    Note: When two generators are connected in parallel for greater wattage loads, an RV (NAME TT-30) adaptor is provided.

  9. 120V 5-20R
    Control Functions inductions

    The Outlet is used to power 120V Single Phase 60Hz loads requiring up to 1600W continuous power.

  10. .Ground Terminal
    Properly ground generator to prevent electrical shock.
    Connect the ground terminal of generator to ground electrode buried in the ground.
    Control Functions inductions

Getting Started

Unpack the generator
Remove the generator from its packaging.
WARNING!
Packaging is flammable! Do not attempt to add fuel to this unit before removing it from packaging. Inspect the generator to ensure that no damage has occurred in shipping or handling. If the unit appears to be damaged, do not add fuel or attempt to start the generator. Check to ensure that you received the following items:

  • Generato
  • 12V Charging Cable
  • Parallel Output Wire
  • Oil Funnel
  • Engine Oil (400ml)
  • RV Adaptor

Adding engine oil
The generator has been shipped with engine oil.
Do not add fuel or start the engine before adding engine oil. In order to add motor oil, you will need to remove the side panel from the unit (figure 1).
Adding engine oil
figure 1

Place the generator on a level surface.
Do not tilt the generator while adding oil. It can cause you to overfill the oil and/or cause the oil to leak into areas in which it is not intended. Remove the oil filler cap (figure 2).
Adding engine oil
figure 2

Using the funnel (provided) fill with 0.42 quart SAE 10W-30 or 10W-40 (figure 3). See figure 4 for proper oil level.
Adding engine oil
figure 3
Replace oil filler cap and secure side panel with screws.
Adding engine oil
figure 4

Recommended engine oil:
YAMALUBE 4 (10W-40)
SAE 10W-30 or 10W-40
SAE #30
SAE #20
SAE #10W

Recommended engine oil grade: API Service SE type or higher Engine oil quantity: 0.4L (0.42 US qt)

Adding fuel
Adding engine oil

Do not overfill the tank, otherwise it may overflow when the fuel warms up and expands.

  1. Use clean, fresh, regular unleaded fuel with a minimum octane rating of 85.
  2. Do not mix oil with fuel.
  3. Clean area around the fuel cap.
  4. Remove the fuel cap.
  5. Be sure that the fuel strainer is in place.
  6. Slowly add fuel to the tank.
  7. Do not exceed the red marker position of the fuel filter
  8. Screw on the fuel cap and wipe away spilled fuel.
    Note: Use only unleaded gasoline. The use of leaded gasoline will cause severe damage to internal engine parts. After filling with fuel, make sure the fuel tank cap is tightened securely

Starting the engine
Operate the engine in a well ventilated area.
Do not connect any electrical devices to the outlets on the generator before starting the engine.

  1. Turn the Economy Throttle switch “OFF”. You may turn the Economy Throttle switch to “ON” once the engine is started and a steady idle is achieved.

  2. While holding the fuel tank cap so that it will not move, turn the air vent knob to “ON” position.

  3. Turn the Multi-Switch to “START” position

  4. Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter.

  5. Pull slowly on the recoil starter until it is engaged and then pull it briskly.

  6. After the engine starts, warm up the engine until the engine does not stop when the choke knob is returned the run position.

Stopping the engine
Before stopping the engine, turn off and disconnect any electronic devices attached to the generator.

  1. Turn the Multi-Switch to the “STOP” position.

  2. While holding the fuel tank cap so that it will not move, turn the air knob to “OFF” position.

Electrical Connection

Capacity
Follow these simple steps to calculate the running and starting watts necessary for your purposes.

  1. Select the electrical devices you plan on running at the same time.
  2. Total the running watts of these items. This is the amount of power you need to keep your items running.
  3. Identify the highest starting wattage of all devices identified in step1.

Power management
Use the following formula to convert voltage and amperage to watts: Volts x Amps = Watts To prolong the life of your generator and attached devices, follow these steps to add electrical load:

  1. Start the generator with no electrical load attached.
  2. Allow the engine to run for several minutes to stabilize.
  3. Plug in and turn on the first item. It is best to attach the item with the largest load first.
  4. Allow the engine to stabilize.
  5. Plug in and turn on the next item.
  6. Allow the engine to stabilize.
  7. Repeat steps 5 to 6 for each addition.

Connecting electrical loads

  1. Let the engine stabilize and warm up a few minutes after starting.
  2. Prior to power tools and equipment, make sure the generator’s rated voltage, and amperage (120V AC at 7 AMP, 12V DC at 8 AMP) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
  3. Once the generator is running, simply connect the power cords of 120V AC powered tools and equipment into the 120V AC dual outlets and/or the power cord of a 12V DC powered tool to the DC terminals.
  4. Do not connect 3-phased loads to the generator.
  5. Do not connect 50Hz loads to the generator.
  6. Do not overload the generator.
    Note: The DC terminal may be used for charging 12V automotive type batteries only.

Parallel connection within 2 generators
Performance: Allows you to increase the output by connecting two generators together. By using the parallel connection wires provided. Instant increased power once connected: Parallel running watts = 3420 watts / 28 AMP

Attention: Be sure that generators are powered off and without load when connecting the parallel wires.
Parallel connection

  1. Put the parallel connection wire 1 and 2 into the parallel connection sockets 3 and 4.
    Attention: Grounding wire must be properly connected.
    Parallel connection
    Parallel connection

  2. Start 2 sets of inverter generators. The starting operation is as the same as normal process (refer on manual book starting parts).
    Attention: Please make sure the parallel connection wires have been put into the parallel connection sockets properly. If not connected properly, inverter generator could be   damaged.

  3. The load plugs can now be plugged into socket 6.
    Parallel connection
    Warning: Only 2 sets of ENKEEO generator can be parallel connected. Only use ENKEEO parallel connecting wire. Make sure to connect the correct parallel wire into the correct socket. Connect the parallel wires when generator is off.

Battery charging
Start the engine first and allow it to reach idle before connecting the generator to the battery. Battery charging is performed using the 12V DC outlet only.

  1. Be sure the Throttle switch is turned “OFF” while charging batteries.
  2. Be sure to connect the red battery charger lead to the positive (+) battery terminal, and connect the black lead to the negative (-) battery terminal. Do not reverse these positions.
  3. Connect the battery charger leads to the battery terminals securely so that they do not disconnect due to engine vibration or other disturbances.
  4. Charge the battery by following the instructions in the owner’s manual for the battery.
  5. The DC Circuit Breaker will turn “OFF” automatically if the current exceeds rated output.
  6. To restart charging the the battery, turn the DC protector on by pressing its button to “ON”.
  7. Refer to the owner’s manual for the battery to determine charging times.
    Note: Never start or stop the generator with electrical devices plugged in or turned on.

Maintenance

Periodic maintenance
Periodic inspection, adjustment and lubrication will keep your generator in the safest and most efficient condition possible.

Item

|

Routine

|

Prior to use

| Every
---|---|---|---
6 months or 100h| 12 months or 300h

Spark plug

| • Check conditions

• Clean and replace if necessary

| |

|
Fuel| • Check fuel level and leakage| •| |

Fuel hose

| • Check fuel hose for cracks or damage

• Replace if necessary

|

| |

Engine oil

| • Check oil level in engine| •| |
• Replace| | •|
Air filter element| • Check condition

• Clean

| | •|

Muffler screen

| • Check condition

• Clean or replace if necessary

| |

|

Spark arrester

| • Check condition

• Clean or replace if necessary

| |

|

Fuel filter

| • Check condition

• Clean or replace if necessary

| | |

Spark plug maintenance

The spark plug is an important engine component and should be checked periodically.

  1. Open the side panel ①.
    Spark plug

  2. Remove the spark plug cap ②.
    Spark plug

  3. Insert the tool ③ through the hole in the outside of the cover.

  4. Insert the handlebar ④ into the tool and turn it counter clockwise to remove the spark plug.
    Spark plug

  5. Check for discoloration. The carbon porcelain insulator around the center electrode of sparks plug should be a medium-to-light tan color.

  6. Check the spark plug type and gap. The spark plug gap should be measured with a wire thickness gauge and, if necessary, adjusted to specification.
    Spark plug

  7. Install spark plug, spark plug cap, cover and screws.

Engine oil replacement

Initial replacement of the engine oil is after one month or 20 hours of operation.

  1. Place the generator on a flat surface and warm up the engine for several minutes.
    Then stop the engine and turn the Fuel Petcock knob to “OFF” and the Fuel Tank Cap Air Vent knob to “OFF”.
    Engine oil replacement

  2. Open the side panel ①
    Engine oil replacement

  3. Remove the oil filler cap

  4. Place an oil pan under the engine. Tilt the generator to drain the oil completely
    Engine oil replacement

  5. Return the generator to a level surface.
    Note: Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.
    Engine oil replacement

  6. Add engine oil to the upper level.

  7. Install oil filler cap, cover, and screws.
    Engine oil replacement

Air filter maintenance
Should be performed every 6 months or 100 hours. The air filter may need to be cleaned more frequently when using in unusually wet or dusty areas.

  1. Open the side panel ①.
    Air filter

  2. Remove the screws ① and then remove the air filter case cover ②.
    Air filter

  3. Remove the foam element ①.
    Air filter

  4. Wash the foam element in solvent and dry it.

  5. Oil the foam element and squeeze out excess oil. The foam element should be wet but not dripping.
    Note: Do not wiring out the foam element when squeezing it. This could cause it to tear.

  6. Insert the foam element into the air filter case. Be sure the foam element sealing surface matches the air filter so there is no air leak.
    Note: Never operate the engine without foam element.

  7. Install air filter case cover, cover, and screws.

Muffler screen and spark arrester maintenance

  1.   Open the side panel ①.
    maintenance

  2. Loosen the bolt ① and remove the muffler cap ②, the muffler screen ③ and spark arrester.
    maintenance

  3. Remove the carbon deposits on the muffler screen and spark arrester using a wire brush. Use wire brush lightly to avoid damaging the muffler screen or spark arrester.
    maintenance

  4. Check the muffler screen and spark arrester, replace them if damaged.
    maintenance

  5. Install the spark arrester.

  6. Install the muffler cap.

  7. Install the cover and tighten the screws.
    maintenance

Fuel filter maintenance
Fuel filter maintenance

Should be performed every 12 months or 300 hours of operation.

  1. Remove the fuel tank cap and filter ①.
  2. Clean the filter with gasoline.
  3. If damaged, replace it.
  4. Wipe the filter and install it.
  5. Install the fuel tank cap.
    Warning: Gasoline is flammable. Do not perform this maintenance while smoking or near an open flame.

Storage

Long term storage
Storage
Storage
Storage
Long term storage of your generator will require some preventive procedures to guard against deterioration.

  1. . Drain the fuel
    Remove the fuel tank cap. Extract the fuel into an approved gasoline container using a commercially available hand siphon. Then install the fuel tank cap.
    Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate painted surfaces or plastic parts.

  2. Start the engine and let it run until it stops. Duration of the running engine depends on the amount of the fuel left in the tank.

  3. Open the side panel.

  4. Drain the fuel from the carburetor by loosening the drain screw on the carburetor float chamber. Tighten the drain screw.

  5. Remove the dipstick and drain the engine oil. Then tighten the dipstick.

  6. Install the cover and tighten the screws.

  7. Turn the fuel tank cap air vent knob to “OFF”.

  8. Store the generator in a dry, well-ventilated place, with the cover placed over it.

Engine
Perform the following steps to protect the cylinder, piston, etc. from corrosion.

  1. Remove the spark plug, pour about one table-spoon of SAE 10W-30 OR 20W-40 motor oil into the spark plug. Recoil start the engine by turning over several times (with ignition off) to coat the cylinder walls with oil.
  2. Pull the recoil starter until you feel compression. Then stop pulling (this prevents the cylinder and valves  from rusting).
  3. Clean exterior of the generator and apply a rust inhibitor.
  4. Store the generator in a dry, well-ventilated place, with the cover placed over it.
  5. The generator must be remain in a vertical position when stored, carried, or operated.

Troubleshooting and Specifications

Troubleshooting diagram
Troubleshooting

Specifications

Model SC2300i
Engine Type 4-stroke OHV Air Cooled Single Cylinder EPA Certified
Engine Displacement (cc) 79cc
Running Power 1800W
Starting Power 2300W
Rated Frequency 60Hz
Rated Voltage 120V
Rated Current 15A
Run Time 6.5h at 1/2 load
Receptacles 120V AC (2), 12V DC (1)
Net Weight 23KG
Noise Level 52dB at 1/4 load
Fuel Type Unleaded gasoline
Gallon 1.1
Oil Type SAE 10W-30
Start Type Recoil
Dimensions 22.6 x 14.8 x 21.5 inch

Warranty

Our company provides customers with a warranty of 12 months from the date of purchase.

Contact Us
For any inquiries or comments concerning our products, please send an email to support@enkeeo.com, and we will respond to you as soon as possible.

QR code
http://www.enkeeo.com/

Web: www.enkeeo.com
E-mail: [email protected]

icon

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals