ADVANCE CONTROLLER Platinum Series Controller Instruction Manual

June 6, 2024
ADVANCE CONTROLLER

**ADVANCE CONTROLLER Platinum Series Controller Instruction Manual

**

ADVANCED PEMF  With programmable features:

  • Waveform (Sine, Square)
  • Frequency (1 to 25Hz with 7.83 Hz default)
  • Pulse duration (medium, fast, ultra-fast)
  • Intensity (10% to 100% of 3000 milligauss)
  • Time (20 min, 1 hr)

Billions of PEMF combinations!

POWER ON

  1. Connect Controller to the Mat
    POWER ON

  2. Use Surge Protector
    POWER ON

  3. Turn Power ON
    POWER ON

Information
The controller backlight will automatically turn off if the controller is not touched for more than 2 minutes.

The Controller automatically shuts down if it is not touched for more than 12 hours.

HEAT SETTINGS

HEAT SETTINGS

Information
Actual Temperature is measured at the Core.

Please allow up to 40 minutes for the surface to reach the maximum temp.
HOLD until you hear a BEEP to switch between °F and °C

PHOTON SETTING

PHOTON SETTING

Information
Photon lights turn OFF automatically after 1 hour.
Photon lights can be turned ON again at any time.
Lights operate with or without heat.
Intensity of photon light is 2.5 mW/ cm
Wavelength of photon light is 660 nm

CHANGEABLE PEMF MODE

CHANGEABLE PEMF MODE
CHANGEABLE PEMF MODE

Factory preset PEMF functions description

Program Button Program Type Default Frequencies,in ABCD, Hz
F1 Low Frequencies 1, 3, 4, 6
F2 Medium Low Frequencies 7, 8, 10,12
F3 Medium Frequencies 14, 15, 17, 18
F4 High Frequencies 19, 21, 23, 25
F5 Before Sleep 5, 4, 3, 2
F6 Pain Assist 15, 16, 19, 20
F7 Sports Injury & Strain Assist 24, 24, 25, 25
F9 General Regeneration 7.83, 7.83, 10, 10
F10 Earth Frequencies 7.83.14, 21, 25
F11 Energize Sequence: 110, 18, F6
F12 Relaxation  Sequence: F9, F8, F5

PREPROGRAMMED PEMF FUNCTIONS

FUNCTIONS

Functions
PEMF setting of the active program will be displayed on the screen.

FUNCTIONS
Functions will run in sequence: F10 – 18 – F6 (see Table 1). Controller will shut off after 1 hour. The program is not customizable.

FUNCTIONS
Functions will run in sequence, F9 – F8 – F5 (see Table 1). Controller will shut off after 1 hour. The program is not customizable.

Information
Each preprogrammed PEMF function Fl-F10 consists of 4 programs (ABCD). Each ABCD program is 5 min long and has a unique combination of PEMF Wave Type, Frequency, Pulse duration, and Intensity.

PEMF function can be changed at any time by pressing different F-button. Active ABCD program will restart according to the chosen Function. Functions F1 – F10 can be customized or reset to the factory settings at any time.

PEMF PROGRAMMING MODE

Factory Reset

Factory Reset

To restore the controller to its factory settings

PRESS AND HOLD SIMULTANEOUSLY UNTIL YOU HEAR A BEEP

The Controller will automatically reset and shut down.

TERMS AND DEFINITIONS

  • PEMF Pulse – A short burst of an electromagnetic wave.
  • PEMF Wave – Oscillation (disturbance) that travels through space and matter, transporting energy from one place to another.
  • Wave Type (Sine, Square) – The shape of pulses in an electromagnetic wave. In PEMF this can he Sine, Square or other types, such as sawtooth.
  • Frequency (Hertz, Hz) – The number of individual PEMF Pulses per second. 1 Hz =1 PEMF pulses per second.
  • Pulse Duration – The time from the start of a PEMF pulse, to the end of that PEMF pulse. This is also referred to as “Pulse Width”.
  • PEMF Intensity (Gauss, G) – The measured level of the PEMF magnetic flux density. The unit of measurement is Gauss. 1 Gauss =1000 milligauss = 0.0001 Testa.
  • PEMF Functions (F1-F12) – Factory preprogrammed PEMF functions. Each of the 12 functions consists of 4 programs (ABCD). Each ABCD program has it’s own PEMF settings (PEMF Time, Wave Type, Frequency, Pulse duration, and Intensity).

WARNING

  • Do not use PEMF or high heat settings while pregnant.
  • Do not use PEMF or high heat settings if you have metal implants or a pacemaker.
  • Do not use if you have varicose veins.
  • Do not use with muscle relaxants.
  • Please consult with your doctor if you have any serious medical condition before using this or any medical device.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals