BONECO Ultrasonic Humidifier U250 Instruction Manual
- June 6, 2024
- BONECO
Table of Contents
- INTRODUCTION
- TECHNICAL DATA
- FIRST CLEANING
- OVERVIEW AND PART NAMES
- INDICATORS ON THE DISPLAY
- KEYPAD ON THE APPLIANCE
- STARTING UP AND SWITCHING OFF
- HUMIDITY AND ULTRASONIC
- FRAGRANCE CONTAINER
- NOTES ON CARE
- DESCALING AND CLEANING
- Clean the BONECO U250 with a dish brush.
- ON THE A250
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
U250
MANUAL
Read and save these instructions
Always observe all safety notes (included separately in delivery).
INSTRUCTIONS FOR USE
INTRODUCTION
HEALTHY AIR IS A BASIC NEED.
There is little to which we react with greater sensitivity than poor air. And
yet many people do not pay enough attention to air quality, which has
consequences for health and
quality of life. This makes us all the more pleased that you have chosen a
BONECO appliance to ensure that the basic need for healthy room air is
satisfied for you and the people around you.
AVAILABILITY OF ACCESSORIES
You can obtain replacements for worn-out accessories as well as additional
accessories from:
- Your BONECO specialist dealer,
- At www.boneco.us or
- Directly via the “BONECO healthy air” app.
TECHNICAL DATA
**TECHNICAL DATA***
Power supply voltage | 100 – 240 V ~ 50 / 60 Hz |
---|---|
Power consumption | Standby: 0.1 W |
11 W (“low”)
18 W (“medium”)
20 W (“high”)
Humidity output| 2.2 gal/day (340 g/h)*
For rooms up to| 540 square feet (50 m² / 125 m³)
Water capacity| 0.92 gallons (3.5 liters)
Dimensions L×W×H| 9.4 x 4.7 x 10.4 in. (240 x 120 x 263 mm)
Weight (empty)| 3.3 lbs (1.5 kg)
Operation noise level| 32–33 dB(A)
FIRST CLEANING
Production-related residue on the water base may lead to foaming, and thereby to water escaping. For this reason, before the first use, the water base must be cleaned with warm water and dish detergent. Then thoroughly rinse the water base under running water.
OVERVIEW AND PART NAMES
- Steam output
- Water level indicator
- Cleaning brush
- Function keys
- Display
- Water tank
- A250
- Tank cover
- Fragrance container
- Power supply
INDICATORS ON THE DISPLAY
Symbol| Meaning|
---|---|---
| Current or desired humidity| 14
| Fully automated operation| 14
| Selected performance level| 14
CURRENT
| Value shows the current humidity| 14
DESIRED
| Value shows the desired humidity| 14
| Refill the water| 16
KEYPAD ON THE APPLIANCE
Button| Function|
---|---|---
| Switching appliances on and off| 14
| Controlling output| 14
| “AUTO” operating mode| 14
| Change the humidity| 14
STARTING UP AND SWITCHING OFF
HUMIDITY AND ULTRASONIC
SAVING SETTINGS
The BONECO U250 saves the last-used settings when it is switched off. However,
if the appliance is disconnected from the power outlet for a few seconds, it
will start in the
operating mode.
“AUTO” OPERATING MODE
After switching on, the appliance is in operating mode. The desired relative
humidity level (rH) is pre-set to 50% in operating mode. The appliance selects
the
suitable performance level Low “L” / Medium “M” / High “H” to reach the rH
value of 50% as soon as possible.
In operating mode, the rH can be modified at any time using the button. If the performance level is modified using the button, the operating mode switches off automatically, and the appliance is in manual operating mode.
The heater can be switched on or off without the appliance exiting operating mode. the operating mode also remains active when setting the timer.
To return to operating mode, tap the symbol once.
CONTROLLING HUMIDITY
The humidity can be set between 30% and 70%. In the “Co” setting (for
“Continuous”), the ultrasonic runs regardless of the measured humidity. This
means it does not switch
off until the tank is empty or the appliance is switched off.
- Tap the symbol. The current humidity display starts flashing
- While the display is flashing, tap the symbol again until the desired humidity is set.
The value is applied after a few seconds. The display stops flashing.
CONTROLLING OUTPUT
- Tap the symbol multiple times until the desired level appears on the display.
The symbol on the display indicates which of the three levels (low/medium/high) has been selected:
FRAGRANCE CONTAINER
BASICS
Commercially available fragrances and essential oils can be inserted into the
fragrance container on the rear side.
Never mix any additives into the water base itself, since doing so can decrease the performance of the BONECO appliance and even cause damage. This damage is not covered by the warranty.
USE
-
Press down on the fragrance container to take out the drawer.
-
Sprinkle the felt insert in the drawer with the fragrance of your choice.
-
Reinsert the fragrance container.
The fragrance container can be cleaned in the dishwasher. The temperature may not exceed 50 °C.
NOTES ON CARE
CARE INSTRUCTIONS
With time and use, the performance of the A250 decreases and scale builds up
on the inner parts of the BONECO U250. Stagnant water can also impair
cleanliness and
lead to unpleasant odors. This means regular maintenance and cleaning is
necessary to ensure clean and unimpaired operation.
Recommended cleaning and maintenance intervals vary depending on air and water quality, and operating time.
Use a soft, damp cloth to clean the exterior.
Always unplug the appliance from the power outlet before cleaning.
Interval | Task |
---|---|
Daily | Check the water level; add water if necessary |
After 1 week without operation | Empty and clean the BONECO U250 |
Every 2 weeks | Clean the water base and water tank |
Every 2–6 months | Replace A250 |
DESCALING AND CLEANING
ON DESCALING
If stubborn limescale deposits form at the bottom of the BONECO U250, the
appliance must also be descaled in addition to the cleaning. For this process,
use the provided
EZ-Cal “CalcOff” descaling agent. You can obtain a refill of the agent from
your BONECO specialist dealer.
The appliance must always be unplugged from the power outlet before draining it. Failure to do so can result in electric shock and pose the risk of severe or fatal injury!
Do not let water get into the ventilation opening! This will damage the appliance.
DESCALING THE APPLIANCE
-
Disconnect the BONECO U250 from the power outlet.
-
Drain the water base.
-
Mix the EZCal with approx. 0.5 liters (17 oz) of water and pour the mixture into the humidification chamber.
-
Wait 30 minutes to allow the solution to take effect.
Clean the BONECO U250 with a dish brush.
DESCALING AND CLEANING
CLEANING THE MEMBRANE
Never clean the membrane using sharp objects or aggressive cleaning agents;
doing so can damage the BONECO U250 and void the warranty!
Mineral deposits on the membrane can be removed using the yellow cleaning brush attached inside the base of the BONECO U250.
ON THE A250
PREPARING THE A250
Please observe the accompanying manual for starting up the A250.
ON WATER HARDNESS
The BONECO U250 is supplied with the A250. The granulate contained in it
filters the lime out of the tap water so that it is not released into the room
air. Hard tap water accelerates saturation of the granulate, making it
necessary to replace the A250 earlier.
Dispose of the saturated A250 with your regular household waste.
White dust around the appliance is a sure indication that the A250 is fully worn out.
REPLACING THE A250
The A250 must be replaced every 2 to 6 months. In cases of very hard water, it
may have to be replaced sooner. White dust around the appliance is a sure
indication that the A250 is fully worn out.
Please observe the accompanying manual for starting up the A250.
The used A250 can be disposed of with your regular household waste.
REPLACEMENT
You can obtain replacements from your BONECO specialist dealer or our online
store at www.boneco.us.
B O N E C O is a registered trademark of B O N E C O AG, Switzerland
B O N E C O North America Corp., 15821 Ventura Blvd, Encino, CA 91436
51520-01
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>