PULEIDA PU-600 Power Station User Guide

June 6, 2024
PULEIDA

Puleida PU-600
POWER STATION
http://www.iPuleida.com
Email: Hello@iPuleida.com
User guide
PULEIDA PU-600 Power Station

IMPORTANT SAFETY INSTRUCTIONS

Please read the User Guide carefully before recharging or operating your Puleida PU-600.
IMPORTANT SYMBOLS

WARNING: Indicates potentially dangerous conditions that could result in personal injury
CAUTION: Indicates conditions or practices that could result in damages to the unit or other equipment
NOTE: Indicates procedures or functions that are important for the proper and safe operation of the unit and/or other equipment
WARNING: DO NOT submerge the unit in water or operate the unit in the rain. Doing so may cause short-circuits, electric shocks, and/or fire.
WARNING: DO NOT place the unit near the fire and/or heat the unit. Doing so may cause irreversible damages to the unit and/or battery explosion.
WARNING: DO NOT overload the AC or DC outputs. Please check the specifications of output ports and devices before operation.
Please dispose of the product according to the local recycling and environmental regulations.
WARNING: Please turn off the output ports when no devices are connected to the unit to prevent electric shocks.
CAUTION: DO NOT dismantle or modify the unit. Doing so may cause irreversible damages to the unit and void the warranty.
CAUTION: DO NOT drop or strike the unit. Doing so may cause circuit failures and cracks in the casing.
CAUTION: Keep the unit out of the reach of young children.
CAUTION: DO NOT place the unit under direct sunlight or place in high- temperature situations. Doing so may cause unit malfunction or component degradation.
CAUTION: DO NOT expose the unit to strong electrostatic fields, strong magnetic fields, and/or radiation.
CAUTION: Please check the unit before each use. Stop using the unit if you notice unusual smells, heating, distortion, or any other abnormalities.
CAUTION: If you do not need to use the power station to power the CPAP or other device, you can press and hold the AC button or the DC button to manually turn off the power, in order to make the power station more durable. (Please don’t press both of the buttons at the same time)
CAUTION: DO NOT place the product in a high-temperature sealed environment such as a car for a long time.

FEATURES

REVOLUTIONARY SPEED
The Puleida PU-600’s USB-C port features Power Delivery (PD) technology that can pump out up to 65W power to compatible devices. Quick Charge (QC) technology allows for up to 18W of output power from the USB-A port.
VERSATILE POWERING OPTIONS
The Puleida PU-600 is equipped with multiple commonly used output ports to power essential gadgets and small appliances.
PURE SINE WAVE
Produce clean, silent, and stable AC power up to 600W with the pure sine wave inverter to power delicate electronic devices efficiently and safely.
ULTIMATE SAFETY
The battery management system (BMS) commands voltage control, temperature control, short circuit protection, and overcurrent protection to keep both the power station and your devices safe from damage.

PACKAGE CONTENTS

1 x Puleida Puleida PU-600 Power Station
1 x Wall Charger
1 x User Guide

PRODUCT OVERVIEW

PULEIDA PU-600 Power Station - PRODUCT OVERVIEWSPECIFICATIONS

General

Product Weight| 4.8 kg / 10.6 lb
Material| PC + ABS
Operating / Storage Humidity| 45-95%
Normal Operating Temperature| 0-40℃ / 32-104℉
Certifications| FCC, CE, PSE, RoSH
Battery
Type Lithium-ion Battery|  Lithium-ion
Voltage| 25.9V
Capacity| 518Wh/140000mah
Cycle Life| ≥500
Input
DC Input Port| 10-30V/5A, 90W Max
USB-C PD Port| 60W Max
Output
USB-C(1)PD Port|  65W Max
USB-A(1)+USB-C(2)| 5V/3A, 15W Max
USB-A(2)| QC3.0 18W Max
DC Output & Carport| 12V/10A Shared 120W Max
AC Output| 110V/60Hz(Pure Sine Wave 600W Rated)
Total Continuous Output| 600W

RECHARGING YOUR PULEIDA PU-600

CAUTION: To maximize battery life, be sure to fully recharge your Puleida PU-600 before operating or storing
NOTE: To shorten the recharge time of Puleida PU-600, it is recommended to disconnect all loads while recharging the unit
Recharge Time

  • Recharge via Solar: 5.5 Hours (100W Solar Pan | Depending on weather)
  • Recharge via AC/DC Adapter: 6.5 Hours
  • Recharge via USB-C PD 60W Wall Charger: 9 Hours
  • Recharge via both AC/DC Adapter and USB-C PD Wall Charger: 3.5 Hours

NOTE: The above recharge times are based on conditions when the Pulido PU-600 is recharged at full speed with no loads connected to it.
Recharging via Solar

  • For optimal recharging performance, it is strongly recommended to recharge your Pulido PU-600 using a compatible solar panel (not included) on bright sunny days free of scattered clouds.
  • Place the solar panel under direct sunlight. Steer clear of trees or branches that can shade the solar panel and slow down the recharging process
  • Use the Solar Panel Connectors to DC Adapter Cable to connect the solar panel to the DC Input Port of your Puleida PU-600 and place your Puleida PU-600 in the shade to prevent it from overheating.

NOTE: Electrical shock can occur if the Solar Panel Connectors to DC Adapter Cable is damaged or frayed. DO NOT use a damaged or frayed cable to recharge your Puleida PU-600.
CAUTION: Make sure the open-circuit voltage of the solar panel does not exceed  30V or fall short of 10V.
NOTE: The solar recharge time is highly dependent on solar irradiance and ambient temperature.

Recharging via AC/DC Adapter

  • Plug your Puleida PU-600 into a wall outlet through the DC Input Port using the included AC/DC Adapter.
    PULEIDA PU-600 Power Station - DC Adapter

CAUTION: Electrical shock can occur if the power supply cable of the AC/DC Adapter is damaged or frayed. DO NOT use a damaged or frayed cable to recharge your Puleida PU-600.

Recharging via USB-C PD Wall Charger

  • The Puleida PU-600 is designed to be recharged via a USB-C wall charger. However, for optimal recharging performance, it is highly recommended to recharge your Puleida PU-600 using a USB-C PD wall charger (not included) with a high power rating.

PULEIDA PU-600 Power Station -Wall Charger

Recommended USB Wall Chargers:

  • Apple USB-C Power Adapter: 30W, 61W, 87W
  • Samsung USB-C Power Adapter 45W

WARNING:   Electrical shock can occur if the USB wall charger is damaged. DO NOT use a damaged USB wall charger to recharge your Puleida PU-600.

OPERATING YOUR Puleida PU-600

WARNING: Operating your Puleida PU-600 at high temperatures above 104℉ (40℃) or at low temperatures below 32℉ (0℃) can result in battery performance degradation and service life-shortening. For optimal battery performance and maximum battery life, it is strongly recommended to operate your Puleida PU-600 at room temperature.

Operation Time

  • Battery-Powered Devices:
    Number of Full Charges=140000mAh x 0.90/The Battery Capacity of the Device (mAh)

  • DC Powered Devices:
    Working Hours= 518Wh x 0.90 /The Rated Power of Device (W)

  • AC Powered Devices:
    Working Hours= 518Wh x 0.85 /The Rated Power of Device (W)

NOTE: The above estimation formulas only apply when the Puleida PU-600 has been fully recharged and the device does not draw too much power.
NOTE: Actual number of full charges and working hours may vary from different powering methods and device operation status.

POWERING YOUR DEVICES

DISPLAY
LCD Display for Battery level in percentage
LCD Display for Battery output power in Watt
LCD Display for Battery input power in Watt
LCD Display for charge/discharge time
LCD Display for DC, AC, USB-C, USB-A output
LCD Display for function error
Frequency display (50Hz/60Hz)
BUTTON
Buttons for AC output, LCD on/off, DC output
Press the AC button at least for 2 seconds to turn on/ turn off the AC output
Press the DC button at least for 2 seconds to turn on/ turn off the DC( 5521 DC port and car charger port) output
Button for LCD three modes :
light (Press the LCD button at least for 2 seconds)/
50% bright (click on the LCD button) /
SOS (click on the LCD button), Long(at least for 2 seconds) press button to turn off the LCD Under the AC outlet mode, Press the DC and AC button at the same time at least for 2 seconds to shift the frequency (60Hz/50Hz)
Maximum output power
Maximum output power DC+AC is limited to 600W, Peak power output 950W for 1 second. The fan will turn on when the internal temperature rises up to 45°C (charging mode), the fan will turn off if the internal temperature is down to 40°C (Discharging mode) . the fan noise should be controlled under 60db in 10 cm distance.

OPERATION DESCRIPTION

ABBREVIATION NOTE
BL: BATTERY LEVEL

  • LCD Display for battery level and protection.
  • Display battery level from 0 to 100 as 0%-100% when input.
  • Display battery level from 0 to 100 as 0%-100% when output.

BP: INPUT DISPLAY

  • Input Display: INPUT XXX W
  • Output Display: OUTPUT XXX W
  • When input OTP (Over Temperature Protection): ”INPUT Err” flashes
  •  When output OTP (Over Temperature Protection): ”OUTPUT Err” flashes

AI: AC INDICATOR

  • LCD Display ”AC,Z for AC output power status.

DI: DC INDICATOR

  • LCD Display、’ DC” for DC output power status.

UAI: USB-A INDICATOR USB-A

  • LCD Display” USB-A” for USB-A output status.

UCI: USB-C INDICATOR USB-C

  •  LCD Display” USB-C” for USB-C output status.

LC: LOW CURRENT

  • Low loading current for USB output: lower than 80mA for 12 hours.

LP: LOW POWER

  • Low AC output power for AC output: battery output power lower than 7W for 12 hours.

SLEEP MODE

ALL OFF.

  • USB-C input plug-in or Adapter input plug-in, INPUT Mode.
  • Press the AC button/DC button for 2 seconds to turn on the AC outlet / DC outlet, Type-C, and USB- A outlet automatically. Enter sleep mode on automatically.

CHARGE MODE

BATTERY RECHARGE, BP AND BL ON, CHARGE TIME ON.

  • USB-C input plug-in, the battery is charging.
  • DC adapter input plug-in, the battery is charging.
  • Both USB-C and DC adapter input plug-in, battery is charging.
  • BATTERY LEVEL=100% and the battery is full, stop recharging and LCD turn off.
  • USB-C input and adapter input unplug, No any loading in after 2mins, SLEEP MODE on.

OUTPUT MODE

ONE OF AC/DC/USB-A/USB-C AND ALL OUTPUT BP AND BL ON.

  • If USB-A and USB-C LC, SLEEP MODE.
  • No loading after 12 hours, SLEEP MODE.
  • If USB-A/USB-C/DC/AC OCP, turn off the output, shows”USB-A/USB-C/DC/AC OCP” “Err” flashes.
  • OCP” “Err”.
  • USB-C input or adapter input plug-in, CHARGE MODE.
  • USB-C loading plug-in, USB-C output.
  • If USB-C output OPP, turn off USB-C output and display”OUTPUT Err” and”USB-C” flashes.
  • USB-C loading unplugs, if LC, SLEEP MODE.
  • Press the AC button, turn on AC output.
  • Press the AC button, turn off AC output.
  • If AC output LP, turn off AC output.
  • If AC output OCP, turn off AC output and LCD display ”OUTPUT Err” and”AC” flashes.
  • Battery level lower than 1%, turn off AC.
  • Press (at least 2 seconds) the DC button, turn on DC output.
  • Press(at least 2 seconds) the DC button, turn off the DC output.
  • If any loading, LCD display On.
  • If no loading after 12 hours, when SLEEP MODE, display off
  • When the battery level drops to 0%, the battery symbols will be flashing for 15 seconds and then turn off automatically.
  • Press for at least 2 seconds the LCD button, to switch to the LCD On from 100% bright — 50% bright —SOS— off.

WARNING: The button to turn on The Puleida PU-600 can provide up to 600W total continuous output. Allocate the outputs rationally and follow the specifications of each output port. DO NOT overload your Puleida PU-600.
CAUTION: Battery high-temperature protection may be triggered when the Puleida PU-600 is operating at full load. When this is the case, cool down the unit before resuming operation. See TROUBLESHOOTING for more details.
CAUTION: When using the AC outlets of your Puleida PU-600, keep 4 inches of space on either side of the unit to guarantee efficient heat dissipation of the inverter.
NOTE: Some devices that require high current impulse may not be compatible with the Puleida PU-600 even though they do not exceed the power
ratings of output ports.
NOTE: When the Puleida PU-600 is powering devices that have high power consumption, the battery level can drop quickly. In this case, you may not
get exactly 518Wh of energy.
NOTE: The Puleida PU-600 can be recharged and deliver DC power to your devices simultaneously. However, AC power is not available when the Pulido PU-600 is being recharged.

MAINTENANCE

  • To prolong the service life of your Puleida PU-600, keep it away from harsh sunlight, water, dust, and dirt. DO NOT leave your Puleida PU-600 outside under harsh environments.
  • If possible, keep your Puleida PU-600 connected to a power source when it is not being used, and avoid using large loads when the battery level is low.
  • To maintain a healthy battery, please recharge your Puleida PU-600 at least once every two months.
  • If you do not intend to use your Puleida PU-600 frequently, it is strongly recommended to keep its battery level at around 50% and store it in a clean, dry, and well-ventilated environment with temperatures around 77℉ (25℃) and humidity no higher than 75%.
  • Keep your Puleida PU-600 away from corrosives, fire, and heat sources.

SPECIFICATIONS

  • If your Puleida PU-600 does not operate normally, please refer to the following table for a possible cause and solution.
  • If the following troubleshooting solutions do not work, please contact us for help. Refer to the last page of the User Guide for contact information.
LCD Screen Display Possible Causes Solutions
“INPUT Err” Flashing DC input interface over-voltage

protection/under-voltage protection (Unsuitable power adapter or power input supply)| 1. Please use the AC Adapter
provided by Puleida to charge the
power station.
2. Please use the PD charging
an adapter or solar modules with an output voltage of 10-30V.
AC/DC/TYPE-C/USB Lights
on “OUTPUT Err” Flashing| Corresponding interface
triggers short-circuit protection| ·1. There is a problem with the output port corresponding to the flashing light
·2.After removing the corresponding device, restart and use the  device normally
·3. Check the parameters of the
electrical equipment are within the energy storage adaptation range Check the rated current and rate the voltage of the device)
·4.Restart and use the device normally
—If the device cannot be used normally after reconnecting it, you need to confirm whether there is a problem with the wire or the electrical device has a short circuit.
·A. When the product is not connected to the device, the output is normal.
·B. Connect the wire separately, if the product protection is triggered, there is a problem with the wire.
·C. If the product protection is
not triggered by connecting the wire alone, and the protection is triggered by connecting the device, there is a problem with the device.
Corresponding interface triggers over-current protection
AC indicator and output Err
flashing at the same time
Triggering AC part high
temperature protection
Input OTP Flashing| The battery temperature is not within the safe working temperature of the product during charging or discharging.| Still, the product to cool till it
goes back to the room temperature.
Output OTP Flashing
NO output can be operated
when Power light indicates 0%| Battery under-voltage protection| Recharge the power station

FREQUENTLY ASKED QUESTIONS

F: Why doesn’t my Puleida PU-600 power other devices?
Q: First, make sure the output ports have been turned on by pressing the corresponding Port On/Off Buttons. Then, check the battery level of the unit. Please recharge the unit as soon as possible. Finally, check if the connected device conforms to the specifications of output ports. If the unit still cant power your devices, see TROUBLESHOOTING or contact us for help. Refer to the last page of the User Guide for contact information.
F: Can I replace the battery pack in my Puleida PU-600?
Q: No, the battery pack in Puleida PU-600 is not replaceable. Do not try to dismantle your Puleida PU-600 and replace the battery by yourself. Doing so may cause irreversible damages to the unit and battery explosion.
F: Can Puleida PU-600 be interconnected?
Q: No, the Puleida PU-600 can NOT be interconnected with other power stations. If you are looking for a rechargeable AC power supply with a larger capacity, please visit our official website or contact us for more options. Refer to the last page of the User Guide for contact information.
F: Is the Puleida PU-600 waterproof?
Q: No, the Puleida PU-600 is not waterproof. Please keep the unit away from moisture. Do not submerge the unit in water or operate the unit in the rain. Doing so may cause short-circuits, electric shocks, and fire.
F: Why doesn’t the battery of Puleida PU-600 last as long as I expect?
Q: The battery capacity is rated at 0.2C.When the Puleida PU-600 is powering devices that have high power consumption, the internal resistance of the battery will turn more energy into heat and lower battery capacity as a result. When this is the case, you may not get exactly 518Wh of energy.

MAINTENANCE

  • Pulido products are covered by a 24-month limited warranty from the original purchase date. If any problems occur, please contact us for assistance. Refer to the last page of the User Guide for contact information.
  • We only provide after-sales services for products that are sold by Puleida or retailers and distributors authorized by Pulido. If you have purchased your unit from other channels, please contact your seller for more information about the return and warranty policy.
  • Please register your purchase(s) directly at www.ipuleida.com so that we can stay in touch and contact you.