Sensata Lithium Battery Settings User Guide

June 6, 2024
Sensata

Sensata Lithium Battery Settings User Guide
Sensata Lithium Battery Settings

QUICK REFERENCE GUIDE

Using the Magnum Energy ME-RC or ME-MR Remote Controls, set Magnum Energy inverter/chargers to charge lithium iron phosphate (LFP) batteries.

ME-RVC bridge Access LFP battery settings via built-in RV control panels using the ME-RVC bridge.

STANDARD LFP SETTINGS AVAILABLE FOR THE FOLLOWING MAGNUM ENERGY INVERTER/CHARGER MODELS

  • MS2000
  • MS2012
  • MS2812
  • MS2024
  • MS4024
  • MS4048
  • MSH3012M
  • MSH3012RV
  • MSH4024M
  • MMS1012
  • MMSA1012

ME-RC Remote Control

From the ME-RC Remote Control version 2.9 or higher, program your Magnum Energy inverter/charger to charge lithium batteries.

  • STEP ONE: Set the Low Battery Cutout to battery manufacturer’s specifications.

    • Press Setup

    • Rotate to Low Battery Cutout
      Button Instructions Remote Control
Instructions

    • Press Rotary Knob to select
      Button Instructions

    • Rotate to battery manufacturer’s specs, or 11.0 VDC if not specified.
      Button Instructions Remote Control
Instructions

    • Press Rotary Knob to save
      Button Instructions

  • STEP TWO: Set the Absorb Time setting to battery manufacturer’s specifications. The setting is determined by the 20-hour amp-hour capacity of your battery bank.

    • Press Setup
      Button Instructions

    • Rotate to Absorb Time
      Button Instructions Remote Control
Instructions

    • Press Rotary Knob to select
      Button Instructions

    • Rotate to 1 hour
      Button Instructions Remote Control
Instructions

    • Press Rotary Knob to save

  • STEP THREE: Set the Battery Type setting to LFP.

    • Press Setup
      Button Instructions

    • Rotate to Battery Type
      Button Instructions Remote Control
Instructions

    • Press Rotary Knob to select
      Button Instructions

    • Rotate to LFP
      Remote Control Instructions

    • Press Rotary Knob to save
      Button Instructions

ME-MR Remote Control

From the ME-MR Remote Control version 1.3 or higher, program your Magnum Energy inverter/charger to charge lithium batteries.
Remote Control Instruction

  • STEP ONE: Set the Battery Amp Hours to 200 AH = 1 hour.

    • Press Menu/Home button until the display shows BAT AHRS

    • The current “saved” setting is indicated by an arrow in the bottom right-hand corner of the display

    • Press On/Off/Change button until 200 AH is shown

    • Press Save/Hold button to save the 200 AH setting

  • STEP TWO: Set the Battery Type setting to LFP.

    • Press Menu/Home button until the display shows BAT TYPE

    • The current “saved” setting is indicated by an arrow in the bottom right-hand corner of the display

    • Press On/Off/Change button until LFP is shown

    • Press Save/Hold button to save the LFP setting

  • STEP THREE: Set the Low Battery Cutout to battery manufacturer’s specifications.

    • Press Menu/Home button until the display shows LBCO

    • The current “saved” setting is indicated by an arrow in the bottom right-hand corner of the display

    • Press On/Off/Change button until correct Low Battery VDC setting is shown for your battery specs, or 11.0VDC if not specified.

    • Press Save/Hold button to save the LBCO setting

Guide provided for reference only. Please read the full Owner’s Manual for each remote control.

Company Logo
www.sensata.com

CONTACT US
651-653-7000
800-553-6418
InverterInfo@sensata.com
Power Conversion
www.Magnum-Dimensions.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Sensata User Manuals

Related Manuals