acaia 680474008070 Lunar Water-Resistant Espresso Scale User Manual

June 6, 2024
acaia

680474008070 Lunar Water-Resistant Espresso Scale

Acaia Lunar User Manual
FW 2.6.010

Contents

3 In the Box

3

Introduction

3

Scale overview

4 Getting Started

4

Placement

4

Power on/off

4

Tare weight

4

Switch mode

5 Product Care Information

5

Battery charge

5

Calibration

6 Mode Introduction

6

Mode 1 – Weighing Mode

6

Mode 2 – Dual Display Mode

7

Mode 3 – Timer Starts with Flow Mode ( )

8

Mode 4 – Auto-Tare Timer Starts with Flow Mode (

)

9

Mode 5 – Auto-Tare Auto-Start Timer Mode (

)

10

Mode 6 – Auto-Tare Mode ( )

12 Configuration 16 Appendix

15

Buttons

17

LED indicators

18

Error codes

18

Other

19 Specifications

In the Box
Introduction
Thank you for choosing our scale. The Acaia Lunar is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. Start by checking that your Acaia Lunar box contains all the parts listed below:

Acaia Lunar

Heat Resistant Pad

Micro USB Cable

Acaia Calibration Weight 100 g

Next, follow the instructions in Getting Started to begin using your scale. To take full advantage of the Lunar’s many features, carefully read through the manual, which contains step-by-step procedures, examples, and other information.
Warning: Incorrect handling of this product could result in personal injury or physical damage.

Scale overview

Weighing Pan Power

LED Display Tare

*Note: For the best performance, place the weight in the center of the weighing pan.

3

Getting Started

Placement

Place the scale on a stable and vibration-free surface at a preferably horizontal location.

Power on/off
[Press] to turn on the scale. [Double tap] to turn off the scale.

Tare weight

[Press]

to tare/zero the weight.

Switch mode
[Press and hold] to switch modes. * Please see the “Mode Introduction” section for more details.

4

Product Care Information
Battery Charge
· You can charge the battery by plugging the USB cable into any of the power supplies listed below:
· A computer · A USB wall-charger with an output of 5 volts and 1 amp · A DC car-charger with an output of 5 volts and 1 amp · It takes about 1-2 hours to fully charge the battery from empty. Try not to let the battery completely run out before charging. Charge the battery as needed. · To check remaining battery level, see below for Battery Level Indicator.
Battery Level Indicator
· Remaining battery level can be viewed by pressing and holding the power button while the scale is powered off, until battery level indicator is displayed. · You can also check the battery level by connecting the scale to Acaia Apps.
Calibration

Turn on scale
Turn on the Acaia scale.

Tap T button
Make sure the scale is in weighing mode and the unit is set to gram’, then tap the T’ button rapidly.

See CAL display

Place a weight

Keep tapping the T’ button untilCAL’ is
shown on the display.

Place a weight (100 g/500 g/1000 g) on the scale and wait
until the display shows `End’. Calibration is now
complete!

5

Mode Introduction
Mode 1 – Weighing Mode
In the Weighing Mode, the scale will only display weight, in either grams or ounces.

· There are two different weighing units in Weighing Mode: gram and ounce. A dot will appear in the upper right of the LED display and the scale will read 0.000 when weighing in ounces. · The LED display shows [ 0 .0 ] when the scale is measuring in grams. · The LED display shows [ 0 .0 0 0 ] when the scale is measuring in ounces. · The readability is 0.1 g or 0.002 oz. For high resolution mode, the readability is 0.01 g or 0.0005 oz.

Action Tare Weight Switch Mode

Operation Tap Tare button Press and hold Power button

Note : To change the weighing unit to either gram or ounce, please see Default Unit Setting in the Configuration section (p12).

Mode 2 – Dual Display Mode
In the Dual Display Mode, the scale displays [ 0 :0 0 0 .0 ] with a timer (left) and weight (right).

· There are two different weighing units in Dual Display Mode: gram and ounce. · When the scale is measuring in grams, the LED display shows [ 0 :0 0 0 .0 ]. · When the scale is measuring in ounces, the LED display shows [ 0 :0 0 0 .0 0 ]. · The maximum time that can be displayed is 9 minutes and 59 seconds. When the limit is reached, the timer still goes up to until 999 minutes and 59 seconds. It can be observed through our iOS/Android App.

Action Start/Stop/Reset Timer Tare Weight Switch Mode

Operation Tap Power button Tap Tare button Press and hold Power button

6

Mode 3 – Timer Starts with Flow Mode ( ) – Droplet
When the scale detects the flow of espresso, the timer starts. The timer will stop when the flow stops. *Please note: The flow detection mode is designed to detect the slow trickle of a shot of espresso. The timer may not trigger when attempting to pour from a kettle.
Display
· The LED display shows [ 0 :0 0 0 .0 ] with the timer on the left and the weight on the right in grams. · The LED display shows [ 0 :0 0 0 .0 0 0 ] with the timer on the left and the weight on the right in ounces. · The timer displays from [ 0 :0 0 ] to [ 9 :5 9 ] and then stops.
Mode Description
· The timer starts when the flow of espresso is detected. · When the espresso flow stops, the timer stops.

1 The droplet icon indicates that you are in Timer Starts With Flow Mode.

2 Placing a container on the scale will display its weight.

3 Tare the weight manually.

4 The timer starts when the flow of espresso is detected.

Action Start/Stop/Reset Timer Tare Weight Reset Mode Stop Timer Switch Mode

Operation The timer will start when flow is detected Tap Tare button Double tap Tare button The timer will stop when flow is no longer detected Press and hold Power button

7

Mode 4 – Auto-Tare Timer Starts with Flow Mode ( ) Droplet and Square
This mode is designed for baristas who would like to measure the time of the shot starting from the first few drops of espresso. When a stable weight is detected, the scale will perform the auto-tare operation. After the scale detects the espresso flow, the timer starts. The timer will stop when the espresso flow stops.
Display
· The LED display shows [ 0 :0 0 0 .0 ] with the timer on the left and the weight on the right in grams. · The LED display shows [ 0 :0 0 0 .0 0 0 ] with the timer on the left and the weight on the right in ounces. · The timer displays from [ 0 :0 0 ] to [ 9 :5 9 ] and then stops.
Mode Description · The auto-tare function operates when a stable weight is placed on the scale. · The timer will start automatically when the flow of espresso is detected.

1 This mode is designed to measure the time of the shot starting from the first few drops of espresso.

2 Place a stable weight on the scale.

3 The scale will perform the auto-tare function.

4 When the scale detects the espresso flow, the timer will start.

Action Start/Stop/Reset Timer Tare Weight Reset Mode Stop Timer Switch Mode

Operation The timer will start when flow is detected Tare function operates when the weight exceeds 2 grams Double tap Tare button The timer will stop when flow is no longer detected Press and hold Power button

8

Mode 5 – Auto-Tare Auto-Start Timer Mode ( ) Triangle and Square
This mode is for baristas to measure the total time of a shot including the pre-infusion time. After a stable weight such as a cup is placed on the weighing pan, the scale performs auto-tare and starts the timer.
Display · The LED display shows [ 0 :0 0 0 .0 ] with the timer on the left and the weight on the right in grams. · The LED display shows [ 0 :0 0 0 .0 0 0 ] with the timer on the left and the weight on the right in ounces. · The timer displays from [ 0 :0 0 ] to [ 9 :5 9 ] and then stops.
Mode Description · The scale performs auto-tare once a stable weight is detected, then the timer starts. · The timer stops when the espresso flow stops.

1 This mode is for baristas who would like to measure the total time of a shot, including pre-infusion time.

2 After a stable weight such as a cup is placed on the weighing pan, the scale performs auto-tare and starts the timer.

3 Measure the total time of a shot including the pre-infusion time.

4 When the espresso flow stops the timer stops.

Action Start/Stop/Reset Timer Tare Weight Reset Mode Stop Timer Switch Mode

Operation The timer will start when a stable weight is placed on the scale Tare function starts when a stable weight is placed on the scale Double tap Tare button The timer will stop when flow is no longer detected Press and hold Power button

9

Mode 6 – Auto-Tare Mode ( ) – Square
In this mode, the scale will only perform auto-tare without automatically starting the timer. Put the cup on the scale and auto-tare will be performed. Pull the shot of espresso as usual. When the cup is removed from the scale, the display flashes the final beverage weight and also shows the tare weight of the cup. The weight resets after 30 seconds (to change this reset time, see the Configuration section to edit the [ Au t o _ r ES ] setting).
Display · The LED display shows [ 0 .0 ] with the weight in grams. · The LED display shows [ 0 .0 0 0 ] with the weight in ounces.
Mode Description · The scale performs auto-tare once a stable weight is detected. · The weight resets after 30 seconds.

1 In this mode the scale will only perform auto-tare without automatically starting the timer.

2 Place a stable weight on the scale.

3 Put the cup on the scale and auto-tare will be performed.

4 The weight resets after 30 seconds.

Action Tare Weight Reset Mode

Operation
Tare function is performed when a stable weight is placed on the scale
Double tap Tare button

10

Note: 1. In all three Auto-Start Modes (Timer Starts With Flow Mode, Auto-Tare Timer Starts With Flow Mode and Auto-Tare Auto-Start Timer Mode), the timer will stop when the espresso flow stops.
2. In all Auto-Start Modes, if the scale remains idle for 30 seconds, it will reset timer and perform tare operation.
3. In all Auto-Start Modes, the timer will stop when a negative weight (i.e., removal of cup) is detected.
4. The scale will also display a previous stable weight that captures the coffee weight of the shot when you unload the cup.
11

Configuration

Enter Settings

1. Press and hold Power button while the LED display shows [ : ACAI A ] and then
changes to [ SEt ]. 2. Tap T button to enter Settings. The first setting is [ SLEEP ]. 3. Please refer to the following table for key operations

Action Next Setting Previous Setting Enter Setting Toggle Options Save Option Exit Settings and Return to Modes

Operation Tap Tare button Tap Power button Press and hold Tare button Tap Tare button Press and hold Tare button Tap Power button

Settings Menu
Setting Sleep Timer Zero Tracking Key Sound Zero Range Weighing Filter Default Weighing Unit Weighing Resolution Setting Weighing Mode Dual Display Mode Timer Starts with Flow Mode Auto-Tare Timer Starts with Flow Mode Auto-Tare Auto-Start Timer Mode Auto-Tare Mode Bluetooth On/Off Battery Saving Pre- infusion Timeout Auto-Start Sensitivity Auto-Reset Reset to Default

Display SLEEP t r Ac E b EEP O.r An GE Fi l t Un i t r ESo L No d E 1 No d E 2 No d E 3 No d E 4 No d E 5 No d E 6 b t SEt b At t Sv E Pr E i n Fu SEn SE Au t o _ r ES r ESEt .d

Sub-Menu Options 5, 10 ,20, 30, 60, Off 0.5 d, 1 d, 2 d, 3 d, Off On, Off 2, 100 2, 4, 6, 8, 16, 32, 64, 128 Gram, Ounce hiGh, dEFAUL On, Off On, Off On, Off On, Off On, Off On, Off On, Off 30, 90, 180, Off 10, 30, 60, 120 0.1 g, 0.2 g, Off Off, 10, 30 No, Yes

Default 5 1 d On
100 16 Gram dEFAUL On On On On On On On 90 60 Off 30

12

Sleep Timer Setting [ SLEEP ] 1. Sleep Timer settings can also be configured in the Acaia apps. 2. The number indicates the amount of time before the scale automatically powers off. For example, when 10 is selected, the scale powers off after 10 minutes of being idle if the scale is disconnected from all mobile devices.
Zero Tracking Setting [ t r Ac E ] 1. Zero Tracking is a function for automatically maintaining the zero indication within certain limits. 2. Off: It is not recommended to turn off Zero Tracking because the zero indication can drift easily as the room temperature changes. 3. 0.5 d~3 d: For example, for standard resolution each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set to be 3 d, any initial weight between ± 0.3 g on the weighing pan will be zeroed out gradually. 4. 2 d is recommended in general for the Acaia Lunar.
Key Sound Setting [ b EEP ] 1. Key Sound settings can also be configured in the Acaia apps. 2. Set the Key Sound function to on/off to enable/disable the beeping sound.
Zero Range Setting [ 0 .r An GE ] 1. The Zero Range setting determines the range for which the tare button executes zero operation instead of tare operation. 2. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., ± 40 g for Acaia Lunar. By pressing the tare button, any weight within ± 40 g is zeroed out by zero operation while any weight that lies outside the range is tared out by tare operation. 3. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., ± 2 kg for Acaia Lunar. Therefore, instead of tare operation, zero operation would be executed in this setting whenever tare button is pressed. Notice: The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0 while tare operation would deduct the weight from the weighing result. However, zero operation does not increase the scale capacity.
Weighing Filter Setting [ Fi l t ] 1. The Weighing Filter Setting determines the speed at which the load receptor responds to weight and determines the weighing value. The larger the number, the more stable but slower the weighing result will be. The number shown on the LED display indicates the current filter setting. 2. Press tare button to change the parameter.
Default Unit Setting [ Un i t ] 1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o 2 ] is selected.
Weighing Resolution Setting [ r ESo L ] 1. The default Weighing Resolution is set to [ d EFAUL ]: the division is 0.1 g/0.002 oz. 2. Tap tare button to switch the Weighing Resolution between [ d EFAUL ] and [ h i Gh ]. 3. When the Weighing Resolution is set to high, division will be 0.01 g/0.0005 oz. The default display will show [ 0.00 ] when the scale is set to grams, and [ 0.0000 ] for ounces in Weighing Mode. Note: After setting Weighing Resolution to high, the default display will show [ 0:00 0.00 ] with timer in Dual Display Mode and Auto Start Modes.
13

Weighing Only Mode Setting [ No DE_ 1 ] 1. The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Dual Display Mode Setting [ No d E_ 2 ] 1. The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Timer Starts with Flow Mode
The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Setting [ No d E_ 3 ]

Auto-Tare Timer Starts with Flow Mode
The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Setting [ No d E_ 4 ]

Auto-Tare Auto-Start Timer Mode
The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Setting [ No d E_ 5 ]

Auto-Tare Mode
The default setting is On. · On: Mode enabled. · Off: Mode disabled.

Setting [ No d E_ 6 ]

Bluetooth Setup Setting [ b t _ SEt ] 1. Off: Bluetooth disabled. The scale does not allow any Bluetooth connection. 2. On: Bluetooth enabled. The scale allows Bluetooth connection. The user may connect the scale with Acaia apps.

Battery Saving [ b At t SAv E ] 1. Save up to 20% of your battery by dimming the display after some time. It will return to its original brightness when the scale detects objects on it. 2. The number indicates the amount of time in seconds before the scale enters battery saving mode. 3. Tap the tare button to toggle through the options.

Pre-Infusion Time Out [ Pr E_ i n Fu ] 1.Determines when the scale times out in Auto-Start ( ) mode and two Auto-Start ( ) modes when the timer is manually started. This is most useful for long pre-infusion times and resolves the timeout that sometimes happens for slower pre-infusions. 2. The number indicates the time in seconds it will take for the scale to reset if no espresso flow or weight is detected.

14

Auto-Start Sensitivity [ SEn SE ] 1. Minimum weight is decreased for more sensitivity. This is ideal for slower espresso shots in the modes. Stability depends on environmental noise. The previous firmware started the timer at
~0.6 g into an espresso shot. 2. The number indicates the sensitivity of flow detection in the modes. Smaller value indicates higher sensitivity, but is recommended only for stable working environments.
Auto-Reset [ Au t o _ r ES ] 1. After a cup is removed, the timer will automatically reset. This setting gives you options on how long to wait for the reset. It enables the user to pull successive shots of espresso quickly in the three Auto-Start modes. 2. The number indicates the timeout value in seconds of timer reset after a cup is removed.
Reset to Default Setting [ r ESEt .d ] 1. Select [ YES ] to reset all settings to default value. 2. Press and hold tare button for 1 second until [ SLEEP ] is shown on the LED to reset all settings to default.
15

Appendix

Buttons
Power Button
Tare Button

Function Turn on Turn off Switch mode Start/stop/reset timer Back Tare Tare and reset timer
Switch option
Confirm
Enter Calibration Mode

Example
Press and hold for 0.5 seconds to turn on the scale.
Double-tap to turn off the scale.
While the scale is turned on, press and hold for one second to switch modes.
Tap to start/stop/reset timer.
While in Settings Menu, tap to go back to Modes.
Tap to perform tare operation.
While in Auto-Start Modes, double tap to zero weight and reset timer.
While in Settings, tap to advance through sub-menus. While in sub-menus, tap to toggle options.
While in Settings, press and hold for two seconds to confirm the option selected in a sub-menu.
While in Weighing Mode, rapidly tap to enter Calibration Mode.

16

LED Indicators

Battery Charge
Tare Operation / Bluetooth Connected

Ounce Indicator Timer Starts with Flow Timer Starts with Tare Auto-tare Operation

Battery Charge/Charge Error The orange indicator on the upper left turns on when the battery is charging and turns off when the battery is fully charged. The indicator starts flashing or does not appear when the USB cable malfunctions.
Tare Operation/Bluetooth Connected The orange indicator on the lower left turns on when the Tare button is pressed.
Ounce Indicator The orange indicator on the upper right turns on when the weighing unit is in ounces.
Timer Starts with Flow ( ) When the scale detects the flow of espresso, the timer starts. The timer will stop when the flow stops. *Please note: The flow detection mode is designed to detect the flow of espresso. The timer may not trigger when attempting to pour from a kettle.
Timer Starts with Tare ( ) The scale performs auto-tare and simultaneously starts the timer when a stable weight is placed on the weighing pan.
Auto-Tare Operation ( ) The scale performs auto-tare when a stable weight is placed on the weighing pan.

17

Error Codes

Error Code 100 101 102 303
304
904 H2O H2O H2O

Description Access Code Error, unrecognized access code. EEPROM error, unable to access memory. Please contact Acaia support. AD error, unable to access weighing signal. Please contact Acaia support. Unable to find acceptable starting Zero point, most likely due to loadcell damage caused by excessive force or drop. Please contact Acaia support. Over load: the weight is over the maximum capacity. Under load: the weight is under the minimum capacity. Calibration error. Calibration cannot proceed when environmental noises are too strong. Please calibrate in a stable environment free of wind, vibration, etc. Password error (the default password is 0000). Water in the power button. Water in the tare button. Water in the power button and tare button.

Other

Display Code Description

UPdAtE

The scale is in update mode. Note: If you want to leave update mode, please connect the scale’s USB to a power source.

18

Specifications

Model Product Weight Product Dimensions Maximum Capacity Minimum Weight Measuring Units Readability Repeatability Linearity Indication Limit Power Supply Battery Battery Life Display Material
Surface
Connectivity Warranty
Inside the Package

AL001 / AL006 / AL007 265 g ± 5 g W: 105 mm L: 105 mm H: 15 mm 2000 g / 70.55 oz 0.1 g gram, ounce 0.1 g 0.1 g 1 d (d = 0.1 g) 2060 g / 72.66 oz
5 V / 500 mA Lithium-ion rechargeable 3.7 V 1100 mAh Up to 27 hours 8-digit LED Aluminum, Acrylic Anodized aluminum coating (Black / Silver) Hydrophobic ceramic coating (White) Bluetooth 4.0 2 Years Acaia Lunar Coffee Scale x 1 Heat Resistant Pad x 1 Micro USB Charging Cable x 1 Acaia Calibration Weight 100 g x 1

19

Copyright
This user manual is protected by copyright. All rights reserved. No part of this manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written consent of Acaia.
© Acaia, California, 2021.