ZyAura ZG1683RU 3 In 1 CO2 Monitor Instruction Manual

June 6, 2024
ZyAura

**ZyAura ZG1683RU 3 In 1 CO2 Monitor Instruction Manual

**

Product Overview

Thank you for selecting ZG1683RU desktop CO2 monitor, ZG1683RU CO2 monitor is smart, compact and easy-to-use. In addition to measuring the CO2 concentration, ZG1683RU can also measure the ambient temperature and the relative humidity (CO2+Temp. +RH). This product is developed to detect the presence of CO2 in ambient air and help people to take care of Indoor Air Quality. ZG1683RU can be widely used in the office building, school, exhibition hall, shopping mall, meeting room, fitness center, restaurant and other public places where personal comfort, healthy is important.
Product Overview
Product Overview

  1. Green LED Display (<800ppm)
  2. Yellow LED Display (800-1200ppm)
  3. Red LED Display (>1200ppm)
  4. Mute Button
  5. Power Inlet
  6. Housing Stand
  7. Screw Position

Features

  • Three different LED display shows the current Indoor Air Quality
  • Press MUTE button for alarm on/off.
  • Built in the LCD Backlight for easy reading in the dark.

Warnings

  • Please take off the AC power adapter and store it well when this CO2 monitor left idle for long.
  • This CO2 monitor is for home use, not suitable for certifying the test results.
  • If use this CO2 monitor for testing, ZG1683RU does not guarantee the test results.

EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
Note: Under the electromagnetic field of 3V/m, the reading will not meet the specification.

Warm-Up Time: 2 MIN

  1. min. warm-up time when first time power.
  2. The LCD shows 4 bars with 1sec blank cycle during warm-up
  3. The MUTE button is disabled during warm-up
  4. The device shows the CO2 reading after warm-up
    Warm-Up Time

Using the MUTE function

Press MUTE button to select buzzer on/off. If the “MUTE” function is off, while CO2 concentration exceed the alarm level (>1200 ppm), there will be a buzzer.
Note: The device setting with alarm is buzzer on when power on first time, user can set the alarm on/off under MUTE function.
MUTE function

Connect to PC with data log function:

  1. The ZG1683RU connect with PC first.
  2. http://www.zyaura.com/products/ZG1683R.asp “Connect to PC with data log function (ZG1683RU )” for the software (ZyAura_USB_HUB_PC_software.rar) and installation processes.

Safety Instructions

Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning and entire User Manual before using the product. These are important safety information and should be observed at all times.

  1. Please handle the devices lightly, do not subject the product to impact or shock.
  2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in damage.
  3. Do not keep the product under the hot and moisture environment. Keep the product away from the heat source or near water.
  4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death to the user.

Caring for product

To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.

  1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
  2. Repair—-Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product needs servicing.
  3. Air circulation—The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked.

Specifications

Method: Dual Beam NDIR
Display:  LCD Independent CO2, RH and Temperature readings
Sample Method: Diffusion or flow through (50 ~200 ml/min)

CO2 & Temperature Specification

CO2 Specification


Measurement Range| 0-3,000 ppm display
Display Resolution| 1ppm at 0~1,000ppm; 5ppm at 1,001~2,000ppm; 10ppm at 2,001~3,000ppm
Accuracy| Under 25°C: ±80 ppm or ±5% of reading (≦2000ppm); ±7% reading (>2000ppm)
Repeatability| ±20 ppm @ 400ppm
Temperature Dependence| Typ. ±0.2% of reading per °C or ±2 ppm per °C, whichever is greater, referenced to 25°C
Response Time| About 2min for 63% of step change
Warm-Up Time| 2 min. at 22°C
Zone LED Display| Green: <800ppm; Yellow: 800~1200ppm;Red: >1200ppm
Temperature Specification:
Temperature Range| 0°C to 50°C (32°F to 122°F) display
Display Resolution| 0.1°C (0.1°F)
Display Options| °C/°F
Accuracy| ±1°C( ±2°F) When the fan blows to the device directly, the accuracy of temperature is + / -1.5 degC
Response Time| 20-30 minutes (case must equalize with environment)
RH Specificatio n:
Measurement Range| 20%-90% RH
Display Resolution| 1%RH
Accuracy:| ±5%RH@23°C
Response time:| <5 min for 63% of step change
Operating Conditions:
Operating Temperature| 0°C to 50°C (32°F to 122°F)
Humidity Range| 0 ~ 95% RH non-condensing
Storage Conditions:
Storage Temperature| -20°C to 60°C( -4°F to 140°F)

Power Supply

Power Supply| USB or 5 VDC from external AC/DC adapter which is included in package (Use specified AC adapter only)
---|---
DC Output voltage| 5 VDC
AC Input voltage & Frequency| 100 ~ 240 VAC, 0.2A          50 / 60 Hz

Communication interface

Version

| USB 2.0 low speed function
---|---
OS|

Windows XP ,Windows7

Dimension

Dimension
Dimension
Dimension

Fault Codes & Troubleshooting Guide

This section includes a list of Frequently Asked Questions for problems you may encounter with the ZG1683RU CO2 Monitor.

Fault Icon

| Description of the fault|

Suggested Actions

---|---|---
| The ambient temperature has exceeded the operating temperature range 0°C to 50°C (32°F to 122°F)| This error will clear when the temperature returns to the range between 0°C to 50°C (32°F to 122°F).
| EEPROM System Problem| Please reconnect AC adapter to ZG1683RU CO2 Monitor.

If the “Err5, Err6” still appears, please contact the Service Department for further assistance.

Radiant Innovation Inc. Http://www.ZyAura.com
1F, No.3, Industrial East 9th Road, Science-Based Industrial Park, HsinChu, Taiwan 300.

Ref.No.:052014
Icons

Company Name

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals