rule DB412 Series Dry Bilge Pump with Panel Switch Installation Guide

June 6, 2024
rule

DB412 Series
Dry Bilge Pump with Panel Switch

Installation Instructions

  • The Rule Bilge Pump is self-priming up to 9.5ft (3m).
  • Install the Rule Bilge pump in a clean, dry location. (This is not a submersible pump.)
  • Uses multi-positional ports for easy mounting of the pump.
  • If mounted vertically, the motor should be above the pump head.
  • Use rubber grommets provided to absorb vibration.
  • Use 3/4″ (19mm) i.d. spiral reinforced hose (with a smooth internal bore), or semi-rigid pipework systems.
  • Connect the hose to the inlet and outlet of the pump using stainless steel hose clamps.
  • All suction connections must be airtight and free of sharp bends or restrictions.
  • Inlet hose should run to the deepest point of the bilge area.
  • Run the discharge hose from the pump to the 90° thru-hull.
  • Inlet hose should be cut at an angle in the bilge and be secured on a bulkhead or stringer with stainless steel clamps to pick up all of the bilge water.
  • Install the thru-hull with a water-tight sealant and above the waterline of the vessel.
  • Secure all plumbing hoses to a bulkhead or stringer.