Hultafors 401323 Digital Pocket Level Instruction Manual
- June 6, 2024
- Hultafors
Table of Contents
- Operating manual Digital Spirit Level DPL
- General information
- Description
- Technical data
- Safety instructions
- Getting Started
- Calibration and adjustment
- Delivery contents and accessories
- Troubleshooting
- Manufacturer‘s Guarantee
- EC conformity declaration
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
401323 Digital Pocket Level
Instruction Manual
INCLUDED IN DELIVERY WITH THE DPL
DPL
Belt pouch
AA battery
Operating manual Digital Spirit Level DPL
About this manual
Congratulations on the purchase of your new DPL! You have acquired a Hultafors
measuring instrument, which can make your work easier, faster and more
precise. To utilize the complete functionality range of this measuring
instrument, and to ensure safe operation, please observe the following
instructions:
- Please read this operating manual before starting to use the device.
- Always keep the operating manual near the device.
- Only hand over the device to other users together with the operating manual.
- Never render the attached warning signs unreadable.
Contents
1. General information | 8. Maintenance, storage, and transportation |
---|---|
2. Description | 9. Scope of delivery and accessories |
3. Technical data | 10. Troubleshooting |
4. Safety instructions | 11. Disposal |
5. Getting started | 12. Warranty |
6. Operation | 13. EC conformity declaration |
7. Calibration and adjustment
General information
Signal words and their meaning
DANGER
For an imminent danger that could lead to serious injury or death.
WARNING
For a possibly dangerous situation that could lead to serious injury or death.
CAUTION
For a possibly dangerous situation that could lead to slight injury or
property damage.
NOTE
For application notes and other useful information.
Pictograms and other information
WARNING SIGNS
Warning of dangers in general.
SYMBOLS
Read instructions before use.
Batteries and devices must not be disposed of with household waste.
Do not throw batteries into a fire.
Warning signs on battery: Do not heat the battery above 60 °C.
Description
- On/Off switch
- Hold function (measurement is retained by pressing once) / Toggling between ABS (absolute) and INC (incremental)
- Mode button for switching between measured value settings (°, mm/m, %, in/ft)
- Calibration
- Changing the display resolution
Technical data
Gradient module
Max. measurement tolerance
-0° – 90°| ± 0.05°
-1° – 89°| ± 0.20°
Protection class| IP 52
Power supply| 1 x AA battery
Battery life (at 20°C)| 65 h (if display light switched off, approx. 80h)
Permissible temperatures
Operating temperature| -10°C to +50°C
Storage temperature| -20 °C to +60 °C
Safety instructions
Area of responsibility
MANUFACTURER
Hultafors is responsible for the safe delivery condition of the product,
including the operating manual and the original accessories.
Hultafors Group AB 517 21 Bollebygd, Sweden
OPERATOR
The operator is responsible for using the product as intended, the deployment
of personnel, their training, and the operational safety of the product.
- The operator understands the safety information which is stated on the product and the instructions which are contained in the operating manual.
- The operator shall comply with local regulations relating to safety and accident prevention regulations as well as worker protection laws and regulations.
- The operator shall immediately notify Hultafors if safety-related issues should develop on the product or during its utilization.
- The operator shall ensure that the product is not utilized any further if defects become evident, and he will have the product repaired professionally.
Improper Use
- Use of the device and the accessories without instruction.
- Use of third-party accessories or additional equipment.
- Use outside of the intended limits (see Chapter 3 Technical data).
- Use under extreme temperature fluctuations without adequate acclimatization.
- Disabling of safety devices and removal of hazard notices and labels.
- Unauthorized opening of the device.
- Performance of modifications or alterations to the device or the accessories.
- Deliberate blinding of third parties.
- Inadequate safeguarding at the installation site.
Utilization limitations
The DPL is suitable for continuous use in an atmosphere that can be inhabited
by humans.
- Do not operate the product in explosion-prone or corrosive environments.
- Inform the local safety authorities and safety experts before working in hazardous environments, in close proximity to electrical installations or similar surroundings.
Usage Hazards
GENERAL
WARNING
Missing or incomplete instructions may result in improper or incorrect use.
This can cause accidents with serious damages to persons, property, assets,
and the environment.
- Follow the manufacturer‘s and operator‘s safety instructions.
- Protect equipment and accessories from access by children.
CAUTION
A fall, longer storage, transportation or other mechanical effects can lead to
erroneous measurement results.
Check the unit for damage before use.
Do not use damaged equipment.
- Repairs have to be exclusively performed by Hultafors.
- Before use, check the accuracy of the device (see Chapter 8 Checking the accuracy).
CHARGER/BATTERIES/RECHARGEABLE BATTERIES
DANGER
Strong mechanical influences, can lead to leakage, fire, or explosion of the
batteries or trigger the release of toxic substances.
- Batteries and rechargeable batteries may not be opened or exposed to mechanical loads.
- Damaged batteries, chargers, and charging stations may not be used.
- Repairs have to be exclusively performed by Hultafors.
WARNING
High ambient temperatures and immersion into liquids can cause leakage, fire,
or explosion of the batteries or trigger the release of toxic substances.
- Protect batteries and rechargeable batteries from mechanical influences during transport.
- Do not overheat batteries and rechargeable batteries or expose them to fire.
- Avoid the ingress of moisture into batteries and rechargeable batteries.
- Do not use damaged batteries or rechargeable batteries. Perform proper disposal (see Chapter 11 Disposal).
WARNING
If disposed of improperly third parties can possibly be seriously injured and
the environment polluted. The burning of plastic components generates toxic
fumes which may impair the health of people. Batteries/rechargeable batteries
may explode if they are damaged or heated excessively, and thereby cause
poisoning, burning, corrosion or environmental contamination.
If disposed of negligently unauthorized persons are able to use the product
improperly.
- The product must not be disposed of together with household waste. Dispose of the device and accessories properly (see Chapter 11 Disposal).
- Protect the product at all times from access through unauthorized persons, especially children.
Electromagnetic compatibility (EMC)
Electromagnetic compatibility is the ability of the product to function in an
environment where electromagnetic radiation and electrostatic discharges are
present, without causing electromagnetic interference to other devices.
INTERFERENCE OF OTHER DEVICES BY DPL
Although the product meets the strict requirements of the relevant directives
and standards, Hultafors can not completely exclude the possibility of
interference with other devices (for example, when using the product in
combination with third-party devices, such as field computers, personal
computers, wireless devices, mobile phones, certain cables or external
batteries).
- When using computers and radio equipment make sure to observe the vendor-specific information about electromagnetic compatibility.
- Only use original Hultafors equipment and accessories.
INTERFERENCE OF THE DPL BY OTHER DEVICES
Although the product meets the strict requirements of the relevant directives
and standards, Hultafors can not entirely exclude the possibility that intense
electromagnetic radiation in the immediate vicinity of radio transmitters,
two-way radios, diesel generators, etc. can distort the measurement results.
- When performing measurements under these conditions check the plausibility of the results.
FCC statement
WARNING
The user is cautioned that changes or modifications not expressly approved by
the party responsible for compliance could void the user‘s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. The following two
conditions apply for operation: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE
This device has passed the compliance test for limits for a digital class B
device as per Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
NOTE
This device produces and uses radiofrequency energy and can also emit it. If
it is not installed and used according to the instructions, it may cause
harmful interference to radio communication. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Realign the receiving antenna or set it up in a different location.
- Set up the device further away from the receiver.
- Plug the device into a different electrical outlet.
- Seek advice from the distributor or a technical expert.
NOTE
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Use of the product with Bluetooth
WARNING
Electromagnetic radiation can cause disturbances in other equipment, in
installations (e.g. medical ones such as pacemakers or hearing aids), and in
aircraft. It can also affect humans and animals. Precautions: Although this
product conforms to the most stringent standards and regulations, the
possibility of harm to people and animals cannot totally excluded.
- Do not use the product near gas stations, chemical plants, in areas with an increased risk of explosion, and where blasting takes place.
- Do not use the product near medical equipment.
- Do not use the product in airplanes.
- Do not use the product near your body for extended periods of time.
Getting Started
Prior to initial set-up, check whether the batteries have been installed
correctly in the device.
Inserting batteries
- Open the battery compartment cover.
- Insert battery making sure that the poles of the battery are in the right position
- Close the battery compartment cover.
Only use type AA batteries!
Remove the batteries if the instrument is not used over a longer period of
time.
Operation
Switching On/Off
On:
Press the “On/Off switch” to switch on the gradient module.
Off:
Press the “On/Off switch” for at least 2 seconds to switch off the gradient
module.
Display
If the gradient spirit level is used in the inverted position (upside down –
above your head), the display screen turns too so that the measurement can be
read easily.
The display switches off automatically after 5 minutes, as soon as the device
is no longer being moved.
Acoustic signal
By pressing the display circuit°/mm/m/%/in /ft/on/of switch acoustic (signal
at 0 °and 90 °) for more than 2 seconds the acoustic signaling is switched on.
The closer the gradient spirit level gets to the standard position, the more
rapid the frequency of the acoustic signal. This function assists you with
leveling work, where it is not possible for you to read the measurement from
the display.
Hold function
The current measurement is frozen by pressing the “Hold function” once.
A previously measured value can be “frozen” on the display using this
function.
The measurement remains unchanged until the “Hold function” button is pressed
again.
Toggling between ABS and INC
You can toggle between ABS (absolute) and INC (incremental) by pressing the
“Hold function” for more than 2 seconds.
In the “ABS” (absolute) mode, the measurement result is displayed based on the
device calibration.
In contrast, in “INC” (incremental) mode, the measurement result is displayed
based on a relative reference level.
For example, you can take a measurement on a 5° inclined plane in “ABS” mode
and then toggle to the “INC” function. In doing so, the measurement display is
set to 0°. You can now take additional measurements based on this new zero
value. To leave “INC” mode, press the button again for 2 seconds.
Changing measurement display
- Press “Mode button° / mm / m /% / in / ft /on / off switch acoustic” (Signal at 0 ° and 90 °) to switch between ° / mm / m /% / in / ft.
Changing the display resolution
Press the “Hold function” and the “On/Off switch /Display light” button at the
same time to change the resolutions between: 0.00° and 0.0°.
Bluetooth
Fast and efficient data transfer of measured values can be made directly to a
smartphone via Bluetooth.
NOTE
To pair with a smartphone, launch the Hultafors measures app and connect using
one of the function options.
Calibration and adjustment
Calibration of gradient module
Calibration stage 1 based on position 0°.
- Place the DPL with the measurement surface horizontally.
- Briefly press buttons and .
- Display -1- appears on the screen.
- Press the button briefly, display -1- flashes for approx. 5 seconds.
- Display -2- appears on the screen.
- Turn DPL again by 180°.
- Press the button briefly, display -2- flashes for approx. 5 seconds.
- Measurement display appears on the screen, calibration stage 1 is complete.
Maintenance, storage, and transportation
Cleaning
- Wipe off the dirt with a soft damp cloth.
- Do not use aggressive cleaning agents or solvents.
- Do not immerse the device in the water! Clean and dry wet equipment, accessories, and transport containers prior to packaging them. Only pack equipment again when it is completely dry.
- Keep plug connections clean and protected from moisture.
Storage
GENERAL
- The equipment may only be stored within the specified temperature limits (see Chapter 3 Technical data).
- After prolonged storage check the accuracy of the measuring device before using it.
BATTERIES/RECHARGEABLE BATTERIES
- To store the rechargeable battery remove it from the device or the charging station.
- The storage should preferably be in a dry environment at room temperature (see Chapter 3 Technical data).
- Protect from moisture and humidity. Dry wet or damp batteries before storage, or before usage.
- Before storing for extended periods, charge the battery to 80% capacity (see Chapter 7 Operation). Repeat the process every six months during storage.
- After storage, fully charge the battery.
- Check the battery for any damage before use. Do not use damaged equipment.
Transport
GENERAL
- The device may be damaged by strong vibrations or by falling.
- Never transport the product lose. Always use the original packaging or an equivalent transport container.
- Switch off the measuring device before transporting it.
- Check the unit for damages before use.
BATTERIES/RECHARGEABLE BATTERIES
- When transporting or shipping batteries, the operator is responsible for complying with the applicable national and international laws and regulations.
- Before shipping, remove the batteries from the device.
Delivery contents and accessories
Delivery contents of DPL
PDF
Belt pouch
AA battery
Further information on accessories can be found
at www.hultafors.com
Troubleshooting
Error | Possible cause | Remedy |
---|---|---|
Device is switched on, no display, the screen is not illuminated | • Battery |
flat
• Battery inserted incorrectly
• Device or switch faulty| • Replace battery
• Insert battery correctly
• Contact dealer and have the device repaired
Display jumps or screen “frozen”| • Program error| • Remove battery, wait one
minute, reinsert batteries
Irregular display screen| • Battery power low| • Replace battery
Device switches itself on Commissioning
immediately out again| • Battery empty| • Battery empty
Disposal
If disposed of improperly third parties can possibly be seriously injured and
the environment polluted.
The burning of plastic components generates toxic fumes which may impair the
health of people.
Batteries/rechargeable batteries may explode if they are damaged or heated
excessively, and thereby cause poisoning, burning, corrosion, or environmental
contamination.
If disposed of negligently unauthorized persons are able to use the product
improperly. Measuring tools, accessories and packaging must be recycled in an
environmentally-friendly manner.
The product as well as the accessories – especially the batteries and rechargeable batteries – may not be disposed of with household waste.
- Ensure proper disposal of the device and the accessories.
- Only dispose of batteries in a discharged state.
- Observe the country-specific disposal requirements.
Only for EU countries
Electric tools may not be disposed of with household waste!
According to the European Directive 2002/96/EC on Waste Electrical and
Electronic Equipment and its implementation in national law, no longer usable
electrical and electronic equipment must be collected separately and recycled
in an environmentally friendly manner.
Manufacturer‘s Guarantee
“The manufacturer warrants to the original purchaser stated on the guarantee
card, freedom from defects of the device for a period of two years, with the
exception of batteries, as of the point in time the device is handed over. The
guarantee is limited to repairs and/or replacements at the manufacturer‘s
discretion.
Defects that are caused through improper handling by the purchaser or third
parties, natural wear, and optical flaws that do not affect the usability of
the equipment, are not covered by this guarantee. Claims under this guarantee
can only be invoked if the device is submitted along with the guarantee card,
completely filled out by the dealer, dated, and provided with the company
stamp.
If the guarantee claim is justified, the manufacturer shall bear the transport
costs. The duration of the guarantee will not be extended through repair or
spare parts work which is carried out within the scope of the guarantee.
Further claims are excluded unless these are stipulated by the respective
national legislation. In particular, the manufacturer shall not be liable for
any direct, indirect, incidental, or consequential damages, losses, or
expenses in connection with the use or because of the inability to use the
tool for any purpose whatsoever. Implied warranties for the usage or
suitability for a particular purpose are expressly excluded.”
EC conformity declaration
Declaration of Conformity
We Hultafors Group AB, Hultaforsvägen 21, Hultafors declare under our sole
responsibility that the Product(s)
DPL
to which this declaration relates is in conformity with the following
standards.
EMC
EN61326-1:2013
EN61326-2-2:2013
EN 55011:2009+A1:2010
Radio transfer
EN 301489-1 V2.1.1
EN 301489-17V3.1.1
EN 300328 V2.1.1
EN 62479:2010
Following the provisions of Directive(s)
Electromagnetic compatibility 2014 /53 / EU
Read User Manual Online (PDF format)