PD-USB-DP60 PoE to USB-C Power and Data Adapter User Guide

June 6, 2024
PD-USB-DP60 PoE to USB-C Power and Data Adapter

PD-USB-DP60 Quick Start Guide

  1.  Connect an IEEE ® 802.3af/at/bt-compliant PSE to the PD-USB-DP60’s “PoE IN” RJ45 socket using a standard Cat 5/5e/6 Ethernet cable. (Note: The maximum allowed length of the Ethernet cable is 100 meters).
  2. Check that the “Power” LED is yellow to verify that the PD-USB-DP60 is powered on.
  3. Connect one side of the supplied USB Type-C ® cable to the PD-USB-DP60’s USB-C socket. (Note: Any USB-C connection polarity is allowed.)
  4. Connect the other side of the USB Type-C cable to the USB-C powered device.
  5. Verify that the USB-C powered device is getting power from the PD-USB-DP60.

Ethernet-to-USB-C Data Dongle

If PoE power isn’t available, and wired Ethernet is required, the PD-USB-DP60 can be powered from a USB Host:

  1. Connect one side of the supplied USB Type-C cable to the USB-C host.
  2. Connect the other side of the USB Type-C cable to the PD-USB-DP60’s USB-C socket.
  3. Connect a standard Cat 5/5e/6 Ethernet cable to the PD-USB-DP60’s “PoE IN” RJ45 socket to connect to an IEEE 802.3 10/100/1000 Mbps network.

LED Indicators

LED Appearance Status
Power No Light PD-USB-DP60 is:

powered off or powered on as a dongle
Yellow On| PD-USB-DP60 is powered on
Link/ Act| No Light| No data link
Green On| Data link on
Green Blinking| Data activity on

Specifications

Data

  • PoE IN
  • 10/100/1000 Mbps
  • USB Type-C
  • USB 2.0
  • USB 3.1 Gen 1

Power

  • PoE IN
  • Input Voltage: 42-57 VDC
  • Input Current: 1.75A max
  • USB Type-C
  • 5 VDC/3A
  • 9 VDC/3A
  • 15 VDC/3A
  • 20 VDC/3A

Environmental Information:

  • Operating Temperature: 0°C to 40°C (32°F to 104°F)
  • Operating Humidity: 90% Max (non-condensing)
  • Storage Temperature: -20°C to +70°C (-4°F to +158°F)
  • Storage Humidity: 95% Max (non-condensing)
  • Dimensions: 22.4 mm (H) x 66.8 mm (W) x 105.2 mm (L)
  • Weight: 150g

Notes

  • If the USB host is running the Windows ® operating system, the device driver should be automatically installed (plug and play) after the PD-USB-DP60 is connected.  Linux ® may require driver installation in case the LAN7800 Ethernet controller is missing. Apple ® requires driver installation.
  • If the USB host doesn’t recognize the PD-USB-DP60 as a USB device, please go to the LAN7800 product page to download and install the appropriate device driver.
  • Powering multiple PD-USB-DP60 from the same PoE multiport midspan may affect data/power performance to connected USB-C devices (i.e. laptop) if they are sharing common peripheral equipment such as monitors, projectors, etc.

Technical Support

For technical support please visit the Microchip Technical Support Portal www.microchip.com/support

LAN7800 Driver

To download device drivers for the LAN7800 please visit the LAN7800 WEB page: LAN7800 USA/Canada: +1 877 480 2323
The Microchip name and logo and the Microchip logo are registered trademarks of Microchip Technology Incorporated in the U.S.A. and other countries. All other trademarks mentioned herein are property of their respective companies.
© 2021, Microchip Technology Incorporated. All Rights Reserved. 7/21
DS00003800B

Documents / Resources

| PD- USB-DP60 PoE to USB-C Power and Data Adapter PD-USB-DP60 PoE to USB-C Power and Data Adapter [pdf] User Guide
PD-USB-DP60, PoE to USB-C Power and Data Adapter
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals