sparoma PTH-8 Air Quality Detector CO2 Meter User Manual
- June 6, 2024
- sparoma
Table of Contents
PTH-8 Air Quality Detector-0O2 Meter
IC User Manual DI
https://sparoma.afterservice.viputmsource=card&utmmedium=qrcode
Please scan the QR code for more service
https://sparoma.afterservice.vip )
supportus@sparomaliving.com )
About us
aroma ® witnessed the hardships faced by humans who struggle with air
pollution, experiencing the harm caused by the excessive CO2 to humans-
Hypoxia Asphyxia. We recognized that it’s time to improve individuals’
awareness of air pollution and keep them away from these problems. Let’s take
some action, and breathe fresh air in the future!
PTH-8 air quality monitor is a CO2 meter that is equipped with an exact NDIR
sensor for accurately measuring the CO2 concentration from 400PPM to 5000PPM
in the air. Besides, you can place it anywhere due to the small and portable
design, which means you can monitor the air quality in your room, baby room,
office, or car anytime!
Special Statement: The illustrations of the products, accessories and
user interface in the manual are schematic diagrams, just for reference. If
there are any differences between the actual product and the diagrams, please
refer to the actual product received. The manufacturer will not notify you
separately.
If you have any problems, please contact us with the following information:
supportus@sparomaliving.com )
https://sparoma.afterservice.viputmsource=card&utmmedium=qrcode
Product Structure:
Operating Instruction
Button | Operation | Definition |
---|---|---|
A | Short press | Switch temperature units between °C & °F |
Long press | Power on/off PTH-8 | |
B | Short press | The backlight on / off |
Long press | Turn the buzzer on / off | |
Double Click | Enter the WiFi connection mode | |
A&B | Power off and |
then press A & B
at the same time
for three seconds| Put it in a ventilated place to perform manual
calibration data.
Automatic calibration will be completed after
200-second countdown.
Notice:
1. When the screen is off, the light indicator will be in the state of BLN
control, and the user can wake up the backlight by pressing the button “B”
briefly. 2. The Procedure of Manual Calibration Data: 1) Power off and then
press A & B button at the same time for three seconds; 2) Put it in a
ventilated place; 3) After counting down 200 seconds, the product will
complete the calibration data automatically.
Steps for APP Connection:
- Scan the QR code, and download the “Tuya Smart” APP.
- Double Click button “B” to search the signal.
- After entering the app interface, register/log in to your account, click “HOME ” at the bottom. After switching to the tab, click “+ ” in the upper right corner.
- After entering the search interface, click “Auto Scan” to scan and select the device to be searched, and then click “Next’:
- Complete the above steps, you can start continuous detecting and intelligent operation.
Notice :
-
Double Click button “B” of the product, and wait until “”on the screen of the product starts flashing, indicating that it has entered the networking mode.
-
If there are too many products displayed in the scan list or the PTH-8 devices cannot be found, you can click “Add manually” at the top, and then find the ‘Socket (WiFi)’ to the next step until the detector is connected.
-
During the process of connection, we need to ensure that the product and the mobile phone are in the same Wi-Fi environment
(only for 2.4GHz Wi-FiNetwork), -
The duration of Tuya cloud storage is 2 years
-
Once you connect the CO2 meter with your Tuya account successfully, the data will be updated every 10 mins. Besides, the CO2 value changes more than 1Oppm, temperature changes more 1 C.humidi-ty value changes more than 5%, the meter updates the latest value as well.
Notice:
This monitor can ONLY connect with one Tuya account, if your family would like
to check the data, you can share the data via Tuya APR But your family MUST
register Tuya account first.
Battery Indicator
Warning: Please charge this CO2 detector with USB 2,0 and 5V 1A DC
adapter.
Warning: The length of the USB cable cannot exceed 1 meter if you would
like to use other chargers. Please use the qualified USB cable and DC 5V
adapter!
In general, the battery can be charged fully within 4 to 6 hours. For any
detailed battery status, please refer to the following table.
LCD Display | Status |
---|---|
Battery | Working |
Battery capacity flicking | Charging |
Battery frame flicking | Low Battery |
LED and Emoji Indicator
LED Color | Emoji | Definition |
---|---|---|
Green | CO2 value is within the qualified range |
(400-700 PPM),
Yellow| | CO2 value is within the qualified range,
BUT slightly high, under the alert status
(700-1500PPM).
Red| | CO2 value is excessive (>1500PPM),
**** When the CO2 value exceeds 1500 PPM, not only the led light turns red, but the buzzer also emits the sound like “Di-Di-Di…’!
Specifications
Dimensions | 838332 mm | Weight | 0.32 Lbs |
---|---|---|---|
Input | DC 5V 1A | Battery Capacity | 2400 mAh |
CO2 Measuring Range | 400 PPM- 5000PPM | CO2 Resolution | 1 PPM |
Temperature Measuring Range | -10°C-40°C(±2°C) | ||
14°F-104°F( ± 3.6°F) | Humidity Measuring Range | 20%-80% ( ± 5% RH) | |
Sensor | NDIR Sensor | Alert System | Comfort Level& LED Indicator& Buzzer |
WI Fl Connection | 2.4GHz Wi-Fi | APP | Tuya Smart |
Included Components: PTH CO2 Meter x 1, USB 2.0 Line x 1,
18650 Rechargeable Lithium-ion Battery, User Manual
Notice
1. This product should not be dipped in water, nor should it be placed in a
high-temperature environment exceeding 60 C. 2. This product is the precise
measuring instrument and shall not be dismantled without authorization. 3.
Don’t place it for measuring the air in the environment with too-high-
concentration organic gas for a long time. 4. It is equipped with a lithium
battery. When measuring the air quality in the car, please do not put the
carbon dioxide detector with a lithium battery in the sun.
Warranty:
sparoma® provides our customers with a 1-year-limited warranty. If you have
any questions, please kindly contact us with the following information.
Scan the code or enter the after-service website to obtain warranty
information. ( 0
supportus@sparomalivingi.com )
https://sparoma.afterservice.viputmsource=card&utmmedium=qrcode
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Statement: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF exposure compliance statement: This device has been evaluated to meet the
general RF exposure requirement