siffron MC1298 Intelli Anti Sweep Hook Instruction Manual

June 6, 2024
siffron

siffron MC1298 Intelli Anti Sweep Hook Instruction Manual

Intelli Anti-Sweep Hook

INSTALL

  1. Insert hooks into pegboard of desired location without lower metal lock plate
    Installation Instructions

  2. Allow enough space between the displays so that product does not touch the surface below or obstruct other merchandise.
    Installation Instructions
    Lock Down

  3. Insert the Lock Down Plate into the holes directly below the unit. Rotate up into place, until the screw inserts into back plate.
    Installation Instructions

  4. Tighten screw with a Phillips Head Screwdriver. Close Screw Cover Cap when finished.
    Installation Instructions
    LOADING MECHANDISE

  5. Insert the merchandise by following the ramp upwards until product stops, then turn the knob counter clockwise until product catches hook.

    Installation Instructions

  6. Place Merchandise in the hanging position

  7. Turn Knob counter clockwise until supported by the wire hook
    WARNING: Do not overturn coil. Product will go all the way off the rear of the coil and become inaccessible.
    Installation Instructions
    ATTENTION
    Keep product faced to the front
    DISPENSING MECHANDISE

  8. Open window and insert Price Label.
    Installation Instructions

  9. Hold Product

  10. Turn Knob to Release

  11. 1~3 Dispenses in less than 10 seconds trigger wireless notification to Siffron Echo Box > 3 Dispenses in less than 10 seconds result in full alarm at ECHO Box 3
    Installation Instructions

NOTE: OPERATION GUIDE DOES NOT INCLUDE INITIAL HOOK ACTIVATION/COMMUNICATION INSTRUCTION, WHICH IS NEEDED PRIOR TO LIVE USE.

HOOK OPERATION

DISPENSING WILL ACTIVATE AN LED FLASH AND SILENT RF SIGNAL TO THE ECHO BOX ONCE, EVERY TIME THE MERCHANDISE IS DISPENSED. IF THE LED/RF SIGNAL IS TRIGGERED 4 TIMES WITHIN A 10 SECOND PERIOD, THE HOOK WILL SEND A SILENT ALARM (RF SIGNAL) TO THE ECHO BOX, AND FLASH THE LED FOR 5 SECONDS ON THE HOOK. THE ALARM IS INOPERATIVE WHEN MOVED BACKWARDS FOR STOCKING, TO PREVENT FALSE ALARMS.

Installation Instructions

OPERATION MODES FOR THE ECHO BOXES

THE ECHO BOX (RECEIVER) ’S AUDIO IN “A” MODE WILL PROVIDE AN AUDIBLE BEEP WHEN RECEIVING A SIGNAL FROM THE HOOK; INCLUDING A 5 SECOND ALARM SEQUENCE WHEN THE HOOK ACTIVATES 4 TIMES WITHIN
10 SECONDS. THE OUTPUT TERMINALS WILL ALSO ACTIVATE WHEN IN THE ALARM SEQUENCE. THE RESET BUTTON WILL TURN THE ALARM OFF ON THE RECEIVER-ONLY, AND DOES NOT DEACTIVATE THE HOOK.
“B” MODE: THE RECEIVER AUDIO WILL RESPOND TO THE HOOK THE SAME AS WHEN IN THE “A” MODE, EXCLUDING ANY OUTPUT THROUGH THE AUXILIARY TERMINALS,
DURING THE ALARMING PHASE.

  • Auxiliary Terminals R-SONR-PXAInstallation Instructions
  • No Auxiliary Terminals R-SONR-REC-XA
    Illustrated above is showing a receiver with and without wire terminals.
    Both the Hook and Receiver run on batteries, which are included.
    Hook uses a CR2430 and the receiver uses 3 AAA battereies.

R-SONR-REC-XA RECEIVER WILL ONLY ALARM AND BEEP.

R-SONR-REC-PXA RECEIVER WILL ALARM AND BEEP AND SEND SIGNALS TO THE AUXILLARY TERMINALS.

  • R-SONR-REC-PXA Systems Connections
    Installation Instructions
  1. NC2 Normally CIOSed 2
  2. C2 Cortact 2 tc Normally Closer. & Open
  3. PC Wray Open 2
  4. NO1 Nom*, Open 1
  5. Cl Corlad I lor terralty Closed & Open
  6. NCI Ncernalty Ctased I
  7. VIRG -4V +5 we at
  8. GND Grout
  9. A.113 DISC) modes A
  10. 3V3 3V3 SWAT PD5 Prograrrning
  11. Magnatic Mount Mounting magnets for metal surface.  br metal &tax,

FCC Statement

TThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Information
The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition without restriction.

For More information
Call 800.422.2547
visit www.siffron.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

siffron User Manuals

Related Manuals