AMPETRONIC Loopworks Measure R1
SAFETY
- It is important to read these instructions, and to follow them.
- Keep this instruction manual in an accessible place.
- Clean only with a dry cloth. Cleaning fluids may affect the hardware.
- Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as a power supply cord or plug is damaged, liquid has been spilled or objects have fallen onto the apparatus, the apparatus has been exposed to any rain or moisture, does not operate normally or has been dropped.
- WARNING – To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
Box Contents
- 1 x Loopworks Measure R1
- 1 x Pouch
- 1 x Quick-Start Guide & Handbook
INTRODUCTION
The Loopworks Measure R1 has been designed in conjunction with the Loopworks Measure iOS App as a high quality piece of test equipment for detection and evaluation of the performance of Audio Frequency Induction Loop Systems (AFILS) to the international standard IEC 60118-4. It is simple to use with all types of installation, from simple service point applications through to low spill area coverage designs. Simply hold the Loopworks Measure R1 in the same position the hearing aid will be in once the system is operational: i.e. hold the unit at head height to take measurements: either seated, or standing depending on the venue. A headphone socket is provided to allow audible monitoring and subjective testing of the system. Details of use are given in the Hearing Loop test and commissioning procedure.
OVERVIEW OF UNIT
- 3.5mm (1/8 inch) Jack plug for connection to iOS device running App
- 3.5mm (1/8 inch) Headphone socket
OPERATION OF UNIT
For full instructions on using the meter and app, download the Loopworks
Measure User Manual from the R1 product page at www.ampetronic.comm
Method of use
- Download Loopworks Measure App to device
- Unpack Loopworks Measure R1
- Connect to the iOS device running the App
- Insert the headphones into the socket on the top of the unit to monitor received signal. Adjust the volume using the controls on the device running the App.
- Use as basic meter or sign in to Loopworks Measure to capture test results and generate reports
Purchase Receiver
You will need an R1 Receiver to perform any measurements in the app. The
receiver contains a telecoil and enables your iOS device to accurately measure
magnetic fields. Purchase an R1 Receiver from the Ampetronic website
(www.ampetronic.com) or through your local
distributor.
Sign up for Loopworks
Create a free account to access the Loopworks online portal, and enable
increased functionality on the App. This stage is optional, and you can use
the App in simple meter mode; however, you will need an account to access the
full range of functions and to be able to save data or record audio. Create an
account from within the app or at
loopworks.ampetronic.com
Download the FREE App
If you haven’t done so already, you will need to downloa the FREE Loopworks
Measure App from the Apple App Store using your iOS device.
Connect the Receiver
Start your new App and plug the Receiver into the headphone socket of your
iOS device to activate it. You’ll need an Apple Lightning adapter to use with
the most modern iOS devices. For greater compatibility official Apple products
are recommended. Follow the on-screen instructions to allow access to the
microphone and enter the label number (digits only) printed on the side off
the Receiver. Calibrate
Receiver
Follow the on-screen instructions to calibrate the receiver against your
iOS device’s settings. This is an important function to allow accurate meter
readings to be taken.
Sign in to Loopworks
After successful calibration you will be prompted to sign in when first
opening the app. If you have not already created an account you can register
within the app at this stage. If you choose not to sign in now, you can sign
in via the settings menu at any point. During sign in any existing data will
be synchronised to the app, you can check the synchronisation status and
manually synchronise at any point from the projects menu.
TROUBLESHOOTING
No Headphone signal
Check the headphones are plugged in, and the volume control is turned up.
Low magnetic field strength
Check the loop system is running current. If there is insufficient CURRENT, or
excessive metal loss, the application may require a special loop design to
achieve acceptable performance, contact Ampetronic for advice.
Background noise
Check all loop systems are switched off and not running any current. If the
interference is still present with the loop system switched off, locate and
eliminate the source of the interference before switching the loop system back
on. Monitor with headphones whilst switching other electrical systems such as
power, lighting etc ON and OFF See the full user manual, or the FAQs page
within Loopworks for more troubleshooting advice.
SPECIFICATIONS
PARAMETER | VALUE |
---|
Magnetic field measurement
| Coil orientation: Vertical when unit held upright
Reference level: 400mA/m (in field strength mode)
Frequency response
| 50Hz to 8kHz ±0.25dB 40Hz to 10kHz ±0.5dB 30Hz to 15kHz ±0.3dB
Gain stability: Better than ±0.25dB over all conditions
Audio Inputs
| 3.5mm 4-pole jack plug for connection to Apple iOS device
3.5mm 3-pole jack socket for monitoring with stereo headphones
Calibration power| < 100mW
Measurement power| < 1mW
Dimensions| 52.0 x 27.5 x 9.5mm
Weight| 10g
Operating temp range| -10 to +45°C (Storage -20 to +75°C)
WARRANTY & CALIBRATION
This product carries a one year parts and labour warranty from date of
shipment from Ampetronic. The warranty could be invalidated if the
instructions in this handbook are not followed correctly, or if the unit is
misused in any way.
The Loopworks Measure R1 is calibrated during manufacturing test, and is valid
until one year from the date the equipment leaves Ampetronic. Calibration
review is recommended one year from this date, however this period may be
extended depending on use and requirements.
DECLARATION OF CONFORMITY
Manufacturer:
Ampetronic Ltd. Unit 2, Trentside Business Village Farndon Road Newark
United Kingdom NG24 4XB
Declares that the product:
- Description: Field Strength Meter
- Type name: R1
Conforms to the following Directive(s) and Norm(s):
- Directive 2014/35/EU
- EMC: EN55032:2015 Emission
- EN55103-2 : 2009 Immunity
- Directive: 2014/30/EU
- Safety: EN 60065: 2002+A12:2011
- Directive: 2011/65/EU RoHS
- Part 15: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”
Date : May 2017, J.R. Pieters, Managing Director, Ampetronic Ltd.
Contact information
Website: www.ampetronic.com, Portal:
loopworks.ampetronic.com Technical: