PipeBurst Pro RS500 Wireless Device User Manual

June 6, 2024
PipeBurst Pro

PipeBurst Pro RS500 Wireless Device User Manual
PipeBurst Pro RS500 Wireless Device

Warnings and Precautions

  • RS Devices operate on communications frequencies which are subject to FCC rules and regulations. Specific information about device conformity can be found at: https://www.pipeburstpro.com/disclaimers/
  • Placing RS Devices near large metal objects may decrease or block wireless coverage.
  • End User is responsible that the RS Device functionality and installation meets the desired requirements.
  • This manual may be updated or changed without advanced notice
  • To learn about changing settings via ionleaks.com, refer to the ionleaks.com User Manual.

Basic Overview

The primary function of an RS500 Device is enabling wireless operation of equipment wired to it. The RS Device operates as a control module for standard PipeBurst Pro 5 equipment including the WaterValve and FloMeter.

RS500 Device Features

Dimensions

| 4-1/8” W x 4-3/4” H x 1-1/4” D
---|---
Power Source|

AC Power Adapter

Built-in Sensors

| Ambient Air Temperature Sensor

Tamper Alert Sensor

Voltage|

5 VDC

Housing

| Black ABS Plastic
Audible Notification|

Internal Speaker

Wireless Frequency

| 915 MHz
Input 1 & 2 Options|

WaterValve

FloMeter

Installation and Operation of an RS500 Device

Device association to a Gateway

  1. On your ionleaks dashboard, go to the device tab and select add new device.
  2. Enter in the device ID and device key for the RS500 and click add. Repeat this step for each sensor that needs to be added before proceeding to step 3.
  3. Power on the device with the provided 5 VDC power supply.

RS500 Device Placement

  1. Place an RS500 Device at the desired location.
  2. Complete any necessary wiring of hardware components to the RS500.
  3. Apply AC power to the RS500 device with the provided adapter.
  4. Once an RS Device is in its desired location and running on AC power, press and release the relay button on the side of the RS to ensure functionality.

RS Device Standard Settings Summary

Setting

|

Description

---|---
WaterValve| WaterValve Mode gives feedback and control for connected WaterValves. A WaterValve Can be controlled locally via the push button on the side of the RS500.
FloMeter| FloMeter Mode allows an RS500 to read and report FloMeter data to Ionleaks.com. Users can set custom flow thresholds using Ionleaks.com to alert if abnormal flow is detected. Ionleaks.com is required for FloMeter functionality.
Tamper Alert| If the lid of the sensor is removed, a tamper alert is triggered.
Data Recording Interval| The sensor is set to check-in with the system at a user determined amount of time.

RS500 Device Wiring Diagrams

Wiring Diagrams

LED| Function| On|

Off

---|---|---|---

1

| Power| Power On| Power Off
2| Radio| Radio transmitting|

Sleep

3

| Input 1| Input Closed| Input Open
4| Relay 1 (NC)| Relay Open|

Relay Closed

5

| Input 2| Input Closed| Input Open
6| Relay 2 (NC)| Relay Open|

Relay Closed

RS Device Wiring Diagrams

  • Key Components
    Key Components

  • WaterValve – Control + Feedback
    WaterValve - Control

    • IN 1
      SIG: Green
      GND: Black

    • RLY 1
      COM: Red
      NC: White
      If using two WaterValves, repeat wiring for Input 2 / Relay 2.

  • **FloMeter

**

  *  **IN 2  

SIG: Green
GND: Black
**If using two FloMeters, repeat wiring for Input 1

RS500 FCC-ISED Declaration

FCC § 15.19 Labelling requirements

This device complies with part 15 of the FCC Rules and Innovation, Science and Economic Development Canada (ISED) licenseexempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC § 15.21 Information to user

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC § 15.105 statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. RF Exposure Requirements

To comply with FCC RF exposure compliance requirements, the device must be installed to provide a separation distance of at least 20 cm from all persons.

Canada Class B statement

This Class B digital apparatus complies with Canadian ICES-003

RF Exposure Requirements

This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body.

Maintenance Tips for Optimal Device Performance

  • Clean RS500 Device housing, on a regular basis, with a damp cloth.

Wireless Regulatory Information

  • Model: RS500
  • FCC ID: NCM-RS500
  • IC: 2734A-RS500
  • Frequency Range: 915 MHz

Warranty Information

PipeBurst Pro Products 2/5/7 Year Limited Warranty.
Please visit: www.pipeburstpro.com/warranty to review full warranty details

Customer Support

GreenField Direct, LLC
14015 238th Street
Greenwood, NE 68366
www.pipeburstpro.com/contact
E-Mail: help@greenfielddirect.com
Phone: 866-466-LEAK (5325)
Hours of Operation: Weekdays 8:00 AM – 5:00 PM CT

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals