Rear Panel and Hardware Connection
The following describes the proper steps for connecting your cable modem. Please be sure to follow the steps in the sequence outlined below. Failure to do so could result in improper operation or failure of your cable modem.
Step 1: Connect a cable by feeding the F-connector on the back of the
cable modem. Ensure the center conductor of the 75 ohm coaxial cable is
inserted directly into the center of the F-connector. Secure the coaxial cable
by carefully threading the outer shell of the coaxial cable connector onto the
F-connector in a clockwise direction until tight. Be careful not to over-
tighten the connector or you may damage either the connector or the cable
modem.
Step2: Connect the cable modem to a GbE Ethernet 10/100/1000 Mbps Network
using a RJ-45 male-terminated Ethernet cable. This cable modem equips with
four Ethernet ports, you can connect four PCs to the cable modem at the same
time if necessary.
Step 3 : Connect the AC Adapter to the cable modem by inserting the
barrel- shaped connector into
the mating power connector on the back of the cable modem. Exercise carefully
to ensure the connectors are properly aligned prior to insertion and ensure
the two connectors engage completely. The cable modem is shipped with an AC
adapter. Remember to use only power adapter that came with the cable modem.
Other power adapters might have voltages that are not correct for your
particular cable modem. Using a power adapter with the wrong voltage can
damage the cable modem.
Step 4 : Connect the telephone sets to TEL. Use RJ-11 telephone line to
connect TEL port on the cable modem and telephone socket on telephone.
Front Panel & LEDs
There are 8 Light-Emitting-Diodes (LEDs) located on the front panel to indicate the status information of cable modem.
Accessing the Web Management
For easy-changing the default settings, a Web-based GUI is built-in for your access. Use the following procedures to login to your CBV384Z4.
- Open your web browser.
- Type the default IP address of the CBV384Z4 (http://192.168.1.1) and press Enter
- The Log In page appears. Type the user name and password in the respective fields. User name: admin
Password: each unit has its own password, please refer to the housing label
Configuring Your WAN Connection
The DHCP page allows you to activate/deactivate the DHCP server function of the CBV384Z4, and, if the DHCP server is activated, to see DHCP leases it has provided.
Check your CBV384Z4 Access Information
There are 2 labels pasted to the bottom of CBV384Z4 case. In those labels, you can obtain following information. Please note that the following labels are just examples, each CBV384Z4 has their own label and setting value. Please follow your label information to access and configure CBV384Z4. In normal case, you don’t need to change anything, all setting have been set and work properly.
- Wi-Fi SSID: This is for your CBV384Z4 wireless setting use, this setting has already been set to your CBV384Z4.
- Password: This is the default password for your wireless client when connecting to CBV384Z4. You will be asked to key in this password so as to connect via wireless connection.
- Web Management: This is the URL when you like to access to CBV384Z4. You can simply type http://192.168.1.1 in Microsoft Internet Explorer or any other internet browser to access CBV384Z4 web management page.
- user name: This is the value when accessing CBV384Z4 web management page. You will be asked to key in this default value to access CBV384Z4.
- password: This is the value when accessing CBV384Z4 web management page. You will be asked to key in this default value to access CBV384Z4.
Cable Modem Quick Installation Guide
Federal Communication Commission Interference Statement Thi equipment has been tested and found to comply with the limits for a Class B digital device, pursuant toPart 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
FCC RF Radiation Exposure Statement:
This Transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
FCC Statement
This device complies with Class B Part 15 of the FCC Rules. The device generates, uses and can radiate radio frequency energy and, if not installed and used as instructed, may cause harmful interference to radio communication. Only Coaxial cables are to be used with this device in order to ensure compliance with FCC emissions limits. Accessories connected to this device by the user must comply with FCC Class B limits. The manufacturer is not responsible for any interference which results from use of improper cables, or which results from unauthorized changes or modifications to the device.
Canada-Industry Canada (IC) Operation is subject to the following two
conditions: this device may not cause interference and this device must accept
any interference, including interference that may cause undesired operation of
the device.
IC Radiation Exposure Statement:
This equipment with IC radiation exposure limits set forth for an uncontrolled
environment. To maintain compliance with IC RF exposure compliance
requirements, please follow operation instruction as documented in this
manual.
Warranty
Items sold by manufacturer/distributor/agent, hereinafter called “Seller”, are
warranted only as follows: Except as noted below Seller will correct, either
by repair or replacement at its option, any defect of material or workmanship
which develops within one year after delivery of the item to the original
Buyer provided that evaluation and inspection by Seller discloses that such
defect developed under normal and proper use. Repaired or replaced items will
be further warranted for the unexpired term of their original warranty. All
items claimed defective must be returned to Seller, transportation charges
prepaid, and will be returned to the Buyer with transportation charges collect
unless evaluation proves the item to be defective and that the Seller is
responsible for the defect. In that case, Seller will return to Buyer with
transportation charge prepaid. Seller may elect to evaluate and repair
defective items at the Buyer’s site. Seller may charge Buyer a fee (including
travel expenses, if needed) to cover the cost of evaluation if the evaluation
shows that the items are not defective or that they are defective for reasons
beyond the scope of this warranty.
The Seller makes no warranty concerning components or accessories not
manufactured by it. However, in the event of failure of such a part, Seller
will give reasonable assistance to Buyer in obtaining from the manufacturer
whatever adjustment is reasonable in light of the manufacturer’s own warranty.
Seller will not assume expense or liability for repairs made outside the
factory by other than Seller’s employees without Seller’s written consent.
SELLER IS NOT RESPONSIBLE FOR DAMAGE TO ANY ASSOCIATED EQUIPMENT, NOR WILL
SELLER BE HELD LIABLE FOR INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES. THIS
WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE
IMPLIED WARRANTY OF “MERCHANTABILITY” AND “FITNESS FOR PARTICULAR PURPOSE.”
Note to CATV Sysrem Installer “The EUT must be bonding the screen of the
coaxial cable to the earth at the building entrance per ANSI/NFPA 70, the
National Electrical Code (NEC), in particular Section 820.93, Grounding of
Outer Conductive Shield of a Coaxial Cable.”