BaKon BK5600 Ionization Air Blower Instruction Manual
- June 6, 2024
- BaKon
Table of Contents
BaKon BK5600 Ionization Air Blower Instruction Manual
The unit generates high voltage inside, please read this manual carefully and pay attention to the warning and precautions as below, misuse may potentially cause death of, or serious injury to the user as well as the damage to the ionizer itself.
Precautions
- **** Read this instruction book carefully before operation
- Make sure the input voltage conforms with your local input voltage before Connecting the power
- Make sure power socket is grounded
- If power cord is worn out, replace a new one immediately
- If the unit is in idle for a long time, cut the power off and unplug it
- Use original replacements only
Warning
- Do not touch the ion emitting needle once power is on
- Professionals needed when clean up ion needle
- Turn the power off and discharge the ion needle before change it
- Do not fill stuffs through the air coming or blowing mouth
- Maintain and check the unit regularly
- DO not use the product with flammable items around
Our company has the right for the change of design and final explanation.
The pictures in the product manual just serve as a guide line, all are subject
to our actual products.
Packing List
Item: Quantity
Unit: 1PCS
Instruction Manual: 1PCS
Warranty Card: 1PCS
Certificate of Conformity : 1PCS
Product Features
- Fast neutralization of ion.
- Large coverage area of the ionic current.
- Protected perfectly by grounding.
The ionizing air blower is applied to a wide range of applications, including electronic manufacturing, and assembling, camera and watches assemble and assembling of other precise instruments, plastic film cutting, film laminating, demolding.
Operation Principle
The Ionizing Air Blower can produce large quantity of air current with positive or negative electric charge, which counteract the electric charges on the object. When the object surface has negative electric charge, it attracts the positive one from the air current, or vise versa, thus the electric charge on the object surface is neutralized and the static is removed.
The Ionizing Air Blower has a transverse wind machine to provide the
wind, the volume of which can be adjusted within these 3 grades of wind by a
speed switch.
Ionization Component: the ionization component forms a steady high voltage field under the effect of low-current high-voltage produced by the high- voltage apparatus, and the air is ionized to become ions which is carried out by the air current to the object surface to neutralize the static. The ionization component has a special cleaner to clear the dust on the ion emission needle for the normal condition of the component.
The Ionizing Air Blower has a special ion balance circuit that assures the automatic ion balance.
The static removal function of the The Ionizing Air Blower solves the problems in production caused by static effects, such as the absorbed dust, conglutination in the processing of plastics, leap of the small parts due to static exclusion.
Specification
Input Voltage | AC 220V/50HZ/AC110V/60HZ |
---|---|
Current Consumption | ≥0.1 Amp |
Air Volume | 2.2.4m3/min |
Coverage | 40cmX90cm |
Ionizing Balance | 0±10V(before panel 30cm) |
Static Elimination Time | ≤2s |
Ozone Produced | ≤ 0.03ppm(before blower 15cm) |
Operation Environment | 0-50C Humidity:65% |
Filter Device | Optional |
External Dimension | 140(L) X84(W) X220(H) mm |
Weight | ≈ 2.9kg |
Operation Instructions
-
Installation
The ionizer should be put in a distance of 30-60 from the target and in an area that could distribute the max. ion coverage. By tilting the ionizer body, air blows downward. Fasten the knobs on both sides of the unit after getting the ideal position. -
Operation
First, turn on the power switch.
Revolve the speed controller to adjust the air flow volume.
Turn on the lumination switch to light the working area. -
Maintenance
- Warning: pull out the plug and power off before maintenance to avoid danger.
- The ionizing air blower is designed for more maintenance and less repair.
A. Clean the emission component
To clean the emission point, slide the cleaning brush right and left until the emission needle head is clean. The cleaning should be at least once a week.
B. Clean the air input and air output
The air input net and ion output net should be clean to avoid block of air current.
Soft brushes or compressed air can be used for the parts.
C. Ion balance measurement
Use the Ion testing instrument to measure the ion balance (residual voltage).
D. Removal time of the static measurement
Use the static analysis instrument or the load monitoring board to measure the removal time of the static measurement.
E. Calibration
The ion input of the Ionizing air blower was designed to be steady and fixed. Because of the voltage fluctuation or air humidity in the environment and other factors, the ion balance (residual voltage) can be shifted by a magnitude according to the condition when operating.
Optional Accessories
Filter Sponge Filter Case
Warranty
Repair Warranty (Principle)
Model: ____
Customer: __
Product No:
Date of Production: _
Date of Purchase:___
Issued by: ___
From the date of purchasing, we provide _months repair warranty.
After Sale Suggestion (Subordinate)
Customer:
Delivery Date:__
Address:____
Distributor:__
Invoice NO:
Product Model:___
Warranty Terms:
- The table for feedback from customers should be returned to our company within a month after the date of purchase. ln this way, customers may enjoy one-month repair warranty.
- Repair Warranty and Purchase Certificate should be presented.
- The warranty only applies when all the required documents are available.
- The warranty does not apply when the equipment has received damage through abuse, carelessness, improper installation, accident or mishandling during shipment, connecting to improper line voltage, or has been serviced by anyone other than an authorized factory representative.
- After the warranty period, we are ready to provide charged repair service, perfect as always.
Dear Sir / Madam:
Thank you for purchasing our products. To improve our service and ensure the
proper use of our products, please kindly write down your suggestions:
Name of Product:__
Date of Purchase:__
Your Suggestions.__
Package:__
Functions:____
Others:__
Date:___
The warranty is valid in one year since the purchase of this ,any quality problem found, please send back to us with courier fee to be collected, upon receipt of the returning unit, we will repair it and send back to customer within two working days.
Notice: Please enclose the warranty card along with the returning product, or else we have the right to reject the repairing, thanks for your corporation.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>