join EAP101 Dual-Band WiFi 6 Indoor Access Point User Guide
- June 6, 2024
- join
Table of Contents
join EAP101 Dual-Band WiFi 6 Indoor Access Point User Guide
Package Contents
-
EAP101 access point.
-
AC power adapter with international socket converters
-
Mounting bracket accessory.
-
Mounting bracket security Screw.
-
Screw Kit-4 Screw and 4 Plugs.
-
Console Cable-RJ-45 to DB-9 (Tip SKU Only)
Overview
- 12 VDC power input
- Restart/Reset button
- USB 2.0 port (reserved for future use)
- Console port (reserved for future use)
- LAN1/LAN2 Ports: 1Gbps connection to LAN devices.
- Uplink(PoE) Port: 2.5Gbps connection to 802.3ot PoE.
- System LED Indicators
- 2.4G
- 5G
- Power/Status
- Kensington lock slot
Installation
Warning: For indoor use only. The access point, AC power adapter, and all connected cables are not for outdoor use.
Mount the AP
Mounting on a Wall
-
At the installation location on the wall, use the mounting bracket to mark four holes for the wall plugs and screws (included in the screw kit).
Drill four holes for the wall plugs, and then insert the plugs and top them flush with the wall surface.
Note: Drill 2.5 mm (±0.2 mm) holes for M3 self-tapping screws, or 4.5 mm (±0.2 mm) holes for nylon wall plugs.
Use the four screws to secure the bracket to the wall. -
With its ports facing dovm, place the AP over the bracket flanges and then slide it down until it snaps into its secured position.
Mounting on a Suspended Ceiling T-Bar
- Slide the bracket accessory onto the base of the AP until it dicks into its locked position.
- Use the included security screw to secure the bracket to the AP.
- Position the ceiling-mount dip holders on either side of the T-boor, and then turn the AP until the two dips lock it to the T-bar.
Note: The AP mounting supports two different sizes of suspended ceiling T-bores. The position illustrated above is for 24.5 mm boors. Use the position at a 90 degrees angle for 15 mm bars.
Mounting On a Ceiling Without T-Bars
- At the installation location on the ceiling, use the mounting bracket to mark four holes for the plugs and screws (included in the screw kit). Drill four holes for the plugs, and then insert the plugs and tap them flush with the ceiling surface. Use the four screws to secure the bracket to the ceiling (screw torque must be less than 6 kgf.cm).
- Place the AP over the bracket flanges and then slide it onto the bracket until it snaps into its secured position.
Connect Cables
Connect LAN Cables
- Connect Category 5e or better cable to the Uplink(PoE) 2.5G RJ-45 pod. When connected to a PoE source, the Uplink(PoE) port connection provides power to the unit.
- (Optional) Conned o local LAN switch or computer to the LAN1 or LAN2 1000BASE-T RJ-45 pods.
(Optional) Connect Power Adapter
- When not connected to o PoE source, conned the AC power adopter to the DC power lock on the AP and then plug the adopter into a nearby AC power source.
Check AP LEDs
- 2.4G and 5G LEDs — on green for radio enabled.
- Power/Status LED — on green for normal operation.
Hardware Specifications
AP Chassis
-
Size (WsDiH): 195 x 195 x 39 mm (7.68 x 7.68 x 1.54 in)
-
Weight: (0.65 kg (1.435 Ib)
-
Temperature:
Operating: 0° C to 50° C (32°F to 122° F)
Storage: -20° C to 60° C (-4° F to 140° F) -
Humidity:
Operating: 5% to 95% (non-condensing)
Network Interfaces
-
Ports:
Uplink(PoE) RJ-45 Port: 2.5G, PoE PD
LANI RJ-45 Port: 1000BASE-T
LAN2 RJ-45 Port: 1000BASE-T -
2.4 GHz Radio: IEEE 802.11 b/g/n/ax
-
5 GHz Radio: IEEE 802.11a/ac/n/ax
-
Bluetooth Radio: IEEE 802.15.1
-
Radio Frequencies: 2.4-2.4835 GHz (US, Canada, ETSI, Japan, TW) 5.15-5.25 GHz (lower band) US/Canada, 1W 5.726-5.825 GHz (upper band) US/Canada, 1W
Europe
5.15-5.25 GHz, 5.25-5.35, 5.47-5.725 GHz
Japan
515-5.25 GHz, 5.25-5.35, 5.47-5.73 GHz
Power Specifications
- PoE Input Power: 22.4 W max, 48 VDC-55 VDC; 802.3at-compliant
- AC Power Adapter
AC Input: 100-240 VAC, 50-60 Hz
DC Output: 12 VDC, 2 A
Regulatory Compliances
-
Radio:
EN300 328 V2.2.2 (2019-07)
EN301 893 V2.1.1(2017-05)
47 CFR FCC Port 15.247
47 CFR FCC Port 15.407
IC RSS-247 Issue 2 and RSS-Gen Issue 5
MIC certification Rule, Article 2 Paragraph 1 Item 19
MIC certification Rule, Article 2 Paragraph 1 Item 19-3 -
Emissions
EN 301 489-1 V2.1.1 (2017-02)
EN 301 489-17 V3.1.1 (2017-02)
EN 55032:2015
47 CFR FCC Rules and Regulations Part 15 Subpart B, Class B Digital Device ICES-003, Issue 7 Class B -
Safety
Low Voltage Directive IEC 62368-1:2014;and/or EN 62368-1:2014+A1 1:2017; and/or BS 62368-1:2014+A11:2017
IEC/EN 62368-1, IEC/EN 60950-1
Safety and Regulatory Information
FCC Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Conned the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or on experienced radio/TV technician for help.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment. This
device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
For product available in the USA/Canada market, only channel 1-11 can be operated. Selection of other channels is not possible.
IMPORTANT NOTE
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for on
uncontrolled environment. This equipment should be installed and operated with
minimum distance 24 cm between the radiator and your body.
Professional Installation Instructions
-
Installation personnel
This product is designed for specific applications and should be installed by qualified personnel who have knowledge of RF and its related regulations. A general user shall not attempt to install or modify the equipment configuration. -
Installation location
To meet regulatory RF exposure requirements, this product shall be installed at a location where, during normal operations, the radiating antenna is at least 23 cm away from any nearby persons. -
External antenna
Use only the antennas which have been approved by the applicant. Using non- approved ontenno(s) is prohibited and may produce unwonted spurious or excessive RF transmitting power which may lead to o violation of FCC limits. -
Installation procedure
Please refer to this equipment’s user manual for the procedure details. -
Warning The installation position must be carefully selected so that the final output power does not exceed the limit set forth in relevant regulations. Violation of output power regulations could lead to serious federal penalties.
Industry Canada
This device contains license exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
**IMPORTANT NOTE:
**
IC Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with minimum distance 28 cm between the radiator & your body.
CE Statement
This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 24 cm between the radiator and your body.
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range.
All operational modes:
2.4 GHz: 802.1 1b, 802.11g, 802.1 1n (HT20}, 802.11 (HT4O), 802.1 Tac (VHT20), 802.1 lac (VHT40), 802.1 Tox (HE20), 802.1 Tox (HE40)
5 GHz: 802.11, 802.11n (HT20), 802.1 1n (HT4O), 802.1 Tac (VHT20), 802.11 ac (VHT40), 802.1 1ac (VHT80), 802.1 1ax (HE20), 802.1 Tax (HE4O), 802.1 Tax (HEBO)
BLE 2.4 GHz: 802.15.1
The frequency and maximum transmitted power limit in EU are listed as below:
2412-2472 MHz: 20 dBm
5150-5350 MHz: 23 dBm
5500-5700 MHz: 30 dBm
AT | BE | BG | CH | CY | CZ |
---|---|---|---|---|---|
DE | DK | EE | EL | ES | FI |
FR | HR | HU | IE | IS | IT |
LI | LT | LU | LV | MT | NL |
NO | PL | PT | RO | SE | SI |
SK | TR | UK | – | – | – |
The abbreviations of the countries, as prescribed in above table, where Cony restrictions on pulling into service or any requirements for authorization of use exist.
(CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment is in compliance with the Directive 2014/53/EU and Directive 2014/35/EU.
Japan VCCI Statement
5 GHz band (W52, W53): Indoor use Only.
Warning And Cautionary Message
Warning: This product does not contain any serviceable user
Warning: Installation and removal of the unit must be carried out by
qualified personnel only.
Caution: Wear on antistatic wrist strap or toke other suitable measures
to prevent electrostatic discharge when handling this equipment.
Caution: Do not plug phone jack connector in the RJ-45 port. This may
damage this device.
Caution: Use only twisted-pair cables with RJ-45 connectors that conform
to FCC standards.