Vitec Production Solutions 9402001 LED Stage and Studio Luminaire User Manual

June 6, 2024
Vitec Production Solutions

Vitec Production Solutions 9402001 LED Stage and Studio Luminaire

Vitec Production Solutions 9402001 LED Stage and Studio Luminaire-
fig1

SETUP

  • Mount the GEMINI 2X1 HARD with its included Yoke (see “C” above) and Standard Junior Pin (“AD”) to a rigging or support system rated for the weight of the fixture and its accessories (not included). Always comply with applicable local regulations. Use supplemental safety equipment (e.g. safety chain or cable, not included) as required.
  • Lock the GEMINI 2X1 HARD in its tilt position with the Tilt Lock Knob (“E”). Use the Tilt Lock Screw (“D”) for additional adjustment.
  • To remove the diffuser, push the two Diffuser Latches (“A”), right and left, away from the center of the light fixture. When released, flip the Diffuser Flap (“B”) open. Install a diffuser by setting it in place and pushing the diffuser flap closed until both diffuser latches spring completely back into place.
  • CAUTION: Keep the air intakes (“E”) and the air exhaust space (“K”) clear of blockage. Allow more than 30 cm [12 inches] of clear air space from the rear of the GEMINI 2X1 HARD to the nearest obstruction. Use only covers and accessories approved by Litepanels®, and ensure that they do not obstruct the air intakes or exhaust.
  • Connect a battery to the fixture via the 3-Pin XLR DC Power Input Jack (“O”) (28-33VDC). Or plug into a mains electrical outlet via a powerCON AC power cable connected to the Mains AC Power Input (“M”). Use only a provided AC power cable. Switch the ON / OFF Power Switch (“AC”) to the “ON” position. The GEMINI 2X1 HARD is ready for operation.
  • For information on customizing effects or controlling the GEMINI 2X1 HARD via DMX, refer to the Litepanels GEMINI Effects Details or DMX Map at www.litepanels.com Vitec Production Solutions 9402001 LED Stage and Studio Luminaire-fig3

TROUBLESHOOTING

If the Power/Status Indicator Light (“AB”) turns red, flashes red, and/or the light fixture does not operate normally, navigate the menu to SETTINGS -> SYSTEM -> SYSTEM MONITOR to identify active warning or fault conditions. If warning or fault conditions persist, contact litepanels.com/support

Behavior| Power/Status Indicator| Warning or Fault Condition| Recommended Action
---|---|---|---
There is no light output| Green solid on| No fault; fixture is operating normally| Adjust dimmer knob to change intensity
Green flashes during power up| Green flashes| No fault; fixture is operating normally| Take no action; green flashing stops shortly after power up
Light intensity is decreased by 50%| Green solid on| No fault; Fan is OFF (Local or DMX control)| Change fan settings to enable full output, if desired
Light intensity is decreased by 50%| Red flashes| “C FAN ERR”, “R FAN ERR”, “L FAN ERR”| Check fans for blockage or stoppage
Light is on| Red flashes| “VIN LOW”

(Input Under Voltage Warning)

| Change power source
Light turns off| Red solid on| “VIN LOW” (Input Under Voltage Fault) or

“VIN HIGH” (Input Over Voltage Fault)

| Turn fixture OFF; change power source
Light is on| Red flashes| “LED TEMP”, “RGB TEMP”, “PCB TEMP”

(Over Temperature Warning)

| Check fan and vents for blockage or stoppage;

Turn dimmer down to 0% and allow light fixture to cool

Light turns off| Red solid on| “LED TEMP”, “RGB TEMP”, “PCB TEMP”

(Over Temperature Fault)

| Check fan and vents for blockage or stoppage; Turn light fixture OFF and allow to cool

EU Registration
Vitec Production Solutions GmbH Parkring 29
85748 Garching, Germany
German VAT Registration: DE 174828733 Company Number: HRB111560

Register your product and download the latest firmware at www.litepanels.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals