General Electrical Touch GET002 All-In-One Device Instruction Manual

June 5, 2024
General Electrical Touch

General Electrical Touch GET002 All-In-One Device

Warning

  1. The Device is not a medical device
  2. Temperature accuracy is ±0.5°
  3. The temperature threshold to define if a user has fever is set by SW to 37.5°. Make sure that the threshold is set correctly.
  4. After reboot, wait 15min for the Ambient temperature calibration of the device
  5. The device works only in indoor or semi indoor environments. Avoid direct sunlight or rain
  6. Elevated body temperature in the context of use should be confirmed with secondary evaluation methods (e.g., an NCIT or clinical grade contact thermometer)
  7. Contact information
    Carl Chen Project Manager +86 18606271067 carl_chen@get-tp.com General Electrical Touch Co., Limited Rm.1902, Easey Comm.Bldg.,253-261 Hennessy Road,Wanchai,HongKong, China

Product description

General Electrical Touch GET002 All-In-One Device
FIG1

This product is aimed at the needs of large capacity, high performance, wide application, and Customization in the face recognition application process. It introduces a face recognition intelligent temperature measurement hardware that can be combined with tace recognition algorithms Without user cooperation. Realize living body detection, human face dynamic recognition, body temperature induction measurement, warn of abnormal body temperature and remind users to put on masks to provide users with a safe environment for use. The product is based on Rockchip RK3399, dual-core Cortex-A72 (2.0 GHz) and quad-core Cortex-A53 application processor (1.4 GHz), 200W RGB + IR binocular camera, supports WIFI + Gigabit networking and rich peripheral security interfaces, Meet the needs of user access control management, body temperature detection and identification. The product is suitable for office areas, hotels, passage gates, office buildings, schools, shopping mals, shops, communities, public services, and management, etc. where face recognition and temperature measurement are required.

Features

General Electrical Touch GET002 All-In-One Device
FIG2

Specification and performance

Product List

General Electrical Touch GET002 All-In-One Device
FIG13

Structure diagram

General Electrical Touch GET002 All-In-One Device
FIG4

No. Explanation
1 Microphone
2 Infrared fill light
3 RGB camera
4 Infrared camera
5 Infrared temperature measurement module
6 Fill light (white:fill light, green:pass , red:fail )
7 Infrared sensor module
8 8 Inch Touch Screen
9 Card reading area
10 Fixing screw hole
11 USBOTG
12 USB 3.0
13 Loudspeaker
14 Anti disassembly
15 Reset button
16 Recovery
17 RJ 45
18 10 Pin function interface
19 Reset button

Wiring description

Connect positive| Interface Description|
---|---|---
 |  | ****

RST

| ****

RECOVERY

| DEBUG| USB DEBUG interface|
USB3.0| USB3.0 interface|
 | @}| 0| 0|
r| ****

p __ OTG

|  | ****

“‘,

| Network

port

| 1000M Network port|
1| 12V| 6| D1|
USB| 2| GND| 7| DO|
l l OQ QQQ Q QQ Q l| 3| NC| 8| 485B|
4| COM| 9| 485A|
 | 5| NO| 10| GND|

Note: The electric control lock needs the access control special power supply to supply separately, the condition may increase the UPS uninterrupted power supply

Electric lock wiringGeneral Electrical Touch GET002 All-In-One Device
FIG5

Access controller connectionGeneral Electrical Touch GET002 All-In-One
Device FIG6

Note: The combination of NO and COM is normally open, and the combination of NC and COM is normally closed, respectively to the NO, NC and COM terminals of the access  controller. The corresponding  wiring mark  is printed on the 10PIN interface, please refer to the actual product

Installation Instruction

Environment requirement
In the installation and use of this product, please strictly follow all local electrical regulations. If the equipment is not working properly, please do not disassemble and repair it by yourself, otherwise it will affect the equipment warranty. During installation and use, extreme or extreme environments such as extreme high temperature (or low temperature), high humidity, high backlight, vibration, radiation, and chemical corrosion must be avoided.
Lighting conditions: We recommend installation in indoor or semi-outdoor environment,ensuring a well-lit environment, avoiding direct sunlight or low light affect the recognition speed,to avoid facing the glass doors or glasS walls.
Network: It is recommended to install the network open environment, to avoid the bad effectsof network identification speed and accuracy.
Precautions
Before opening the host device, the screen protector should be torn apart to avoid affecting the accuracy of the camera and infrared recognition.
Location
The recommended installation height of the device is 150cm (camera height).

Recommended staff positionsGeneral Electrical Touch GET002 All-In-One
Device FIG7

Recommended locationGeneral Electrical Touch GET002 All-In-One Device
FIG8

Wrong usageGeneral Electrical Touch GET002 All-In-One Device
FIG9

Wall-mounted installation

On the wall surface about 140cm above the ground.open a groove about 9cm in length and 5cm in depth, and select a box with a depth of 5cm to install and fix it.General Electrical Touch GET002 All-In-One Device
FIG10

sets of wires need to be embedded in advance at the host equipment (reserved wire length is 10cm):

  • 12V power cable RVV2 x 1.0 standard and above, one end is at the host device, and the other end is pulled to the original access control dedicated power supply or the 220V power supply 3 hole socket on the top of the sliding door, When installing.connect to the 12V end of the factory-supplied 12V1.8A power adapter. The 220V power cable of the adapter is directly plugged into the 220V power supply 3-hole socket.
  • Door opening control line RVv2 x 0.5 standard and above, one end is at the host device, and the other end is pulled to the original access control dedicated power supply or the top controller of the sliding door, and connected to their door opening signal interface during installation.
  • Cat5e network cable 8 x 0.5 oxygen-free copper standard and above, one end is at the host device, and the other end is pulled to the weak motor room switch, and connected to the Internet during installation. If it is difficult to increase the wired network, you can consider using wireless when the wireless network is stable.

Installation stepsGeneral Electrical Touch GET002 All-In-One Device
FIG11

  1. Fixed. Fix the wall-mounting accessories to the sidewall with screws 86 on the box.
  2. Connection. Refer to the “Wiring Instructions” to connect the network cable and power cable to the deviceGeneral Electrical Touch GET002 All-In-One Device FIG12
  3. Adjust. Adjust the wiring length until the device can be snapped into the wall-mounting accessory
  4. Lock tightly. Use screws to mount the accessories on the wall to lock the device on both sides. Complete equipment installation

Declaration of toxic and harmful substances



Part name

| Harmful substances or elements
---|---


(Pb)

| ****

(Hg)

| ****

(Cd)

| ****

(Cr(VI))

| ****

(PBB)

| ****

(PBDE)

Shell| 0| 0| 0| 0| 0| 0
Circuit board| 0| 0| 0| 0| 0| 0
Power adapter| 0| 0| 0| 0| 0| 0

This table is compiled according SJ/T11364

0| Indicates that the content of the harmful substance in the part is under the limit specified in GB/T26572
---|---
X| Indicates that the content of the hazardous substance in the component exceeds the limit specified in GB/T26572
 |

This marking period is 10 years.Under normal use conditions.hazardous substancesin electronic and electrical products will not leak or mutate.and will not cause seriousenvironmental pollution or cause serious damage to personal and property safety.

This product meets RoHS environmental requirements.

Product warranty card

Thank you for purchasing our products. I guarantee the interests of our customers. If the products  of our company fail due to quality problems, they can contact the local dealers with the invoice and warranty card.

Warranty notice:

  1. Within one year from the date of purchase, in case of failure under normal use, the company will provide free warranty, parts replacement and other services according to the fault conditions.
  2. The warranty card and purchase invoice are the certificates for our company to provide after­ sales service to customers. This card is valid after the following forms are filled in in in detail and stamped with the official seal of the dealer.
  3. Under one of the following circumstances, free warranty service is not implemented, and maintenance is required at a charge;
  4. Beyond the validity of the warranty.
  5. Damage caused by improper use, maintenance or storage not in accordance with the requirements of the product
  6. Failure and damage caused by dismantling, repairing and refitting products without permission of our
  7. Mechanical failure or damage caused by force majeure.
  8. Wearing parts and random accessories.

Commodity

information

| Trade name|  | Factory number|
---|---|---|---|---
Product model|  | Date of

manutacture

|

Cu s tomer

information

| Unit name|  | Contacts|
Address|  | Contact number|

Sales

information

I

| Name of seller|  | Contacts|
Address|  | Contact number|
Date of sale|  | Invoice number|

ro

=>

2

a.

“‘

| Fault condition| ml;nance| Customer signature| Signature of

maintainer

| Date
 |  |  |  |
 |  |  |  |
 |  |  |  |

This card is issued with the goods, one card for each machine. In order to ensure that you can fully enjoy the right of free warranty service provided by our company, please keep this card properly and do not make up for it if it is lost.

FCC WARNING

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals