BATMAIN S17+ Bitcoin Miner Mining Machine Installation Guide
- June 5, 2024
- BATMAIN
Table of Contents
- BATMAIN S17+ Bitcoin Miner Mining Machine
- Overview
- Specifications
- Setting Up the Server
- Configuring the Server
- Monitoring Your server
- Administering Your Server
- Basic Environmental Requirements:
- Other Environmental Requirements:
- FCC Notice (FOR FCC CERTIFIED MODELS):
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BATMAIN S17+ Bitcoin Miner Mining Machine
Overview
The S17+ server is Bitmain’s newest version in the 17+ server series. Power supply APW9+ is part of S17+ server. All S17+ servers are tested and configured prior to shipping to ensure easy set up.
FRONT VIEW
RARE VIEW
Caution:
- The equipment must be connected to an earthed mains socket-outlet. The socket-outlet shall be installed near the equipment and shall be easily accessible.
- The equipment has two power inputs, only by connecting those two power supply sockets simultaneously can the equipment run. When the equipment is powered off, be sure to power off all power inputs.
- Please refer to the layout above to place your goods in usage in case of any damage.
- DO NOT remove any screws and cables tied on the product.
- DO NOT PRESS the metal button on the cover.
S17+ Server Components
The main components and controller front panel of S17+ servers are shown in the following figure:
APW9+ Power Supply:
Note:
- Power supply APW9+ is part of S17+ server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
Specifications
Product Glance | Value |
---|
Version Model No.
Crypto Algorithm/Coins
| S17+ 266-Aa
SHA256/BTC/BCH
Hashrate, TH/s| 73.00
Reference power on wall, Watt| 2920
Reference power efficiency on wall @ 25°C , J/TH| 40.00+10%
Hardware Configuration
Miner Size (LengthWidthHeight, w/o package), mm (1-1)|
298.0175.0304.0
Net weight, kg (1-2)| 10.00
Setting Up the Server
To set up the server:
- Go to the following site: https://shop.bitmain.com/support.htm?pid=00720160906053730999PVD2K0vz0693
- Download the following file: IPReporter.zip.
- Extract the file.
- Right-click IPReporter.exe and run it as Administrator.
- Select one of the following options:
- Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
- Default – suitable for home servers.
- Click Start.
7. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds).
The IP address will be displayed in a window on your computer screen.
- In your web browser, enter the IP address provided.
- Proceed to login using root for both the username and password.
- In the Network section, you can assign a DHCP IP address (optional).
- Click Save & Apply.
Configuring the Server
Setting Up the Pool
To configure the server:
- click General Settings.
- Set the options according to the following table:
Option| Description
---|---
Pool URL| Enter the URL of your desired pool.
The S17+ servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3).
The pools with low priority will only be used if all higher priority pools are offline.
Worker| Your worker ID on the selected pool.
Password| The password for your selected worker.
3. Click Save & Apply to save and restart the server.
Monitoring Your server
To check the operating status of your server:
- Click the status marked below.
- Monitor your server according to the descriptions in the following table:
Option| Description
---|---
ASIC#| Number of chips detected in the chain.
Frequency| ASIC frequency setting.
GH/S(RT)| Hash rate of each hash board (GH/s).
Temp(PCB)| Temperature of each hash board (°C). (Applied only to server with fixed frequency).
Temp(Chip)| Temperature of the chips on each hash board (°C).
ASIC status| One of the following statuses will appear:
● O – indicates OK
● X – indicates error
● – – indicates dead
Administering Your Server
Checking Your Firmware Version
To check your firmware version:
- In System, click the Overview tab.
- File System Version displays the date of the firmware your server uses. In the examples below, the servers are respectively using firmware version 20191023.
Upgrading Your System
Make sure that the S17+ server remains powered during the upgrade process. If power fails before the upgrade is completed, you will need to return it to Bitmain for repair.
To upgrade the server’s firmware:
- In System, click Upgrade.
- For Keep Settings:
- Select the check box to keep your current settings (default).
- Clear the check box to reset the server to default settings.
- Click the(Browse) button and navigate to the upgrade file. Select the upgrade file, then click Flash image. A message appears notifying you if the S17+ firmware can be upgraded and if yes, will then proceed to flash the image.
- When the upgrade is completed, the following message appears:
- Click one of the following options:
- Reboot – to restart the server with the new firmware.
- Go Back – to continue mining with the current firmware. The server will load the new firmware next time when it is restarted.
Modifying Your Password
To change your login password:
- In System, click the Administration tab.
- Set your new password, then click Save & Apply.
Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds.
Environmental Requirements
Please run your server in accordance with the following requirements
Basic Environmental Requirements:
Climatic Conditions:
Description | Requirement |
---|---|
Operating Temperature | 0-40℃ |
Operating Humidity | 10-90%RH (non-condensing) |
Storage Temperature | -20-70℃ |
Storage Humidity | 5-95%RH(non-condensing) |
Altitude | <2000m |
Site Requirements of the Server Running Room:
Please keep the server running room away from industrial pollution sources:
For heavy pollution sources such as smelters and coal mines, the distance
should be more than 5km.
For moderate pollution sources such as chemical industries, rubber and
electroplating industries, the distance should be more than 3.7km.
For light pollution sources such as food factories and leather processing
factories, the distance should be more than 2km.
If unavoidable, the site should be chosen in the perennial upwind direction of
the pollution source.
Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, equipped with air conditioning for cooling.
. Electromagnetic Environmental Conditions:
Please keep your site away from transformers, high-voltage cables,
transmission lines and high-current equipment, for example, there should be no
high-power AC transformers (>10KA) within 20 meters, and no high-voltage power
lines within 50 meters. Please keep your site away from high-power radio
transmitters, for example, there should be no high-power radio transmitters
(>1500W) within 100 meters.
Other Environmental Requirements:
The server running room shall be free of explosive, conductive,magnetically conductive and corrosive dust. The requirements of mechanical active substances are shown below:
Requirements of Mechanical Active Substances
Mechanical Active Substance | Requirement |
---|---|
Sand | <= 30mg/m3 |
Dust (suspended) | <= 0.2mg/m3 |
Dust (deposited) | <=1.5mg/m2h |
Requirements of Corrosive Gas
Corrosive Gas | Unit | Concentration |
---|---|---|
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O3 | ppb | < 2 |
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of
part per billion.
Regulations:
FCC Notice (FOR FCC CERTIFIED MODELS):
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Household in the
European Union
This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where your purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>