Atlantic PAF-20SV Water Gardens User Manual

June 5, 2024
Atlantic

Atlantic PAF-20SV Water Gardens

Introduction

Thank you for selecting the Tidal Wave PAF-20SV/PAF-25SV/PAF-40SV/PAF-75SV series pumps. Before using this pump please take a moment to review this manual.
To avoid an accident do not use the pump in any way other than as described in this manual. Please note the manufacturer cannot be responsible for accidents arising because the product was not used as prescribed. After reading this manual keep it as a reference in case questions arise during use.Atlantic-
PAF-20SV-Water-Gardens-1

  • The chart volumes shown are in gallons per hour. Operating pumps outside of the recommended range may cause bearing damage and premature failure.

Prior to Operation and Installation

When the pump is delivered, first perform the following checks:

  • Check for any damage to pump and power cable that may have occurred during the shipment.
  • Check the model number to make sure it is the product that was ordered and verify the voltage and frequency are correct.

Caution

  • DO NOT operate this product under any condition other than those for which it is specified. Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water leakage or other problems.

  • DO NOT apply any paint over the stainless steel motor body. Reduced cooling ability will result in overheating, overload, introduce undesirable performance reductions, periodic auto shut-off, and pump malfunction.

  • The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage within 110-120 volt 60 Hz.

  • Never place your hand or any object in or near the inlet opening while this equipment
    is operating. If the pump inlet is clogged, always turn off the power supply, fuse box or circuit breaker and wait until the motor is completely stopped before attempting to remove any clogged material.

  • Please make sure that the power plug and the AC outlet receptacle is protected and away from water or pump discharge hose to prevent accidental electric shock or short circuit.

  • Always operate the pump completely submerged in water.

  • Avoid dry operation, which will not only lower performance but can cause the pump to overheat/malfunction, leading to electrical leakage, shock or premature failure.

  • CAUTION: THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.

  • CAUTION: THIS PUMP HAS BEEN EVALUATED FOR USE IN WATER ONLY.

  • WARNING:

    • RISK OF ELECTRIC SHOCK – THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE
    • THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING TYPE RECEPTACLE.

Before You Start

  • Check the model name plate to make sure once again that the product is of the correct voltage and frequency rating.
  • The setting on the circuit breaker or other overload protector should be made in accord with the rated currency of the pump.
  • Turn off the power supply or circuit breaker before inserting the power supply plug to avoid electrical shock, shorting, or unexpected starting of the pump, which could lead to injury.
  • Never operate the pump while it is suspended in air. The recoil may result in injury or other major accidents.

Electrical Safety

  • Electrical wiring should be installed by a qualified electrician in accordance with all applicable safety regulations. Incorrect wiring can lead to a pump malfunction, electrical shock or fire.
  • Pumps should operate on a designated, 110 volt circuit rated at 15 Amps (minimum).
  • Pump must be protected by a ground fault circuit interrupter (GFCI).
  • Pump must be plugged into a standard, properly grounded, three-pronged outlet.
  • Do not cut the electrical cable. If a cable with cut insulation or other damage is submerged in water, there is a danger of water seeping into the pump motor and causing a short. This may result in damage to the pump, electrical shock or fire. Altering the electrical cable in any way will void the warranty.
  • Never move or handle the pump by pulling on the electrical cable. Make sure the electrical cable does not become excessively bent or twisted, does not rub against a structure in a way that might damage it, and does not come in contact with heated surfaces.

Operation

  • In case of a power outage, turn off the power to the pump to avoid having it start unexpectedly when the power is restored.
  • Pay careful attention to the water level while the pump is operating. Dry operation may cause the pump to malfunction. Pump must always operate while fully submersed.
  • In case of very excessive vibration, unusual noise or odor, turn off the power immediately and consult with your nearest dealer. Continuing to operate the pump under abnormal conditions may result in electrical leakage, electrical shock or fire.

Motor Protection System

  • The pump has a built-in motor protection system. The following reasons may cause the pump to stop automatically regardless of water level.
    • Motor overheating
    • Excessive current
    • Change in voltage polarity
    • Open-phase operation or operation under constraint
  • Repeating cycles of stopping and restarting will damage the water pump. Do not continue operation at low lift, low water level, or while the inlet is clogged with debris. Not only will performance suffer, but such conditions may cause noise, heavy vibration, and pump failure.

Removing the Intake Screen

Atlantic’s TidalWave PAF-Series Pumps are equipped with a removable intake screen for conversion to true 1¼” solids handling capacity. To remove the intake screen and use the pump as a solids handling pump, follow the instructions below:Atlantic-PAF-20SV-Water-Gardens-2

  • There are seven holes with screws in them. Only three of these screws need to be removed to remove the intake screen.
  • Locate these three holes which are denoted by raised bumps and indicated on the image above. You will need a #2 Philips head screwdriver (not included).
  • Once these screws have been removed, pull off the intake screen. You should be able to easily pull it off by hand.
  • If the screen does not pull easily, double-check that the correct screws have been removed.

Maintenance and Inspection

  • Regular maintenance and inspections are a necessity for continued efficient functioning. If any abnormal conditions are noticed, refer to the section on Troubleshooting and take corrective measures immediately.
  • During or after the warranty period, the customer is NOT to disassemble the pump for any reason.

Monthly Inspection

  • Check for any drop in performance. Reduced performance is usually caused by debris blocking the intake screen.
  • Detach the power cable from the receptacle and turn off the power supply (circuit breaker).
  • Disconnect the pump discharge and remove the pump from the water.
  • Remove any accumulated debris from the surface of the pump, inlet screen and impeller.
  • Make sure all nuts and bolts are fastened securely.
  • Do not disassemble the pump for any reason. Disassembly will void the pump warranty. Refer operating and maintenance problems to a qualified technician.

Winterizing

  • Under no circumstances should the pump be left in frozen water.
  • When the pump is out of use for an extended period, wash it and dry it thoroughly, then store it indoors.
    Note: Always run a test operation before putting the pump back into operation. When the pump is left installed in water it should be run at regular intervals (about once per week).

Warranty

All TidalWave PAF-Series Pumps carry a two-year limited warranty. This limited warranty is extended solely to the original purchaser commencing from the date of original purchase receipt and is void if any of the following apply:

  • The pump has been run while not fully submersed.
  • The pump was not run on a dedicated circuit.
  • The cord has been cut or altered.
  • The pump has been misused or abused.
  • The pump has been disassembled other than as described in this manual.
  • Serial number tag has been removed.

Warranty Claims

  • In case of warranty claims, pump should be returned to place of purchase accompanied by original receipt.

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can result in a serious accident. Before ordering repairs, carefully read through this instruction booklet. If the problem persists, contact your dealer.

Problem Possible Cause Possible Solution

Pump does not start

| Power is off| Turn power on

Power failure

| Check power supply or contact local power company

Voltage drop/ Overload

| Check/Replace the GFI (Ground Fault Interrupter)
Power cord is not connected| Connect power cord

Pump stops after starting

|

Pump is overheating

| Submerge pump/Raise water level/ Allow pump to cool

Power/Current overload

| Check length/size of power cable. Check or replace GFI
Impeller is blocked| Remove debris from the impeller chamber

Diminished flow rate or no water flow

| Air lock| Restart/Clean air valve
Obstruction in pump or piping|

Clear obstruction

Piping is too long| Reduce length of pipe
Pump hums

/ Impeller does

not spin

| Impeller is blocked| Clear obstruction

Start capacitor failure

| Capacitors can be replaced by qualified technician

Atlantic-PAF-20SV-Water-Gardens-3

1 Handle
2 Pump Cover
3 Condenser
4 Packing
5 Motor Cover
6 Ball Bearing (upper)
7 Thermal Protection
8 Motor Cover
9 Shaft
10 Motor Case
11 Ball Bearing (Lower)
12 Motor Base
13 Packing
14 Mechanical Seal
15 Pump Base
16 Impeller
17 Packing
18 Pump Case
19 Filter
PAF- 20SV PAF- 25SV

75SV
---|---|---|---|---
Length| 9 1/4”| 9 1/4”| 9 1/4”| 9 1/4”
Width| 6 1/8”| 6 1/8”| 6 1/8”| 6 1/8”
Height| 14”| 14 1/2”| 15”| 16”