Haier 1422179 Ductless Single Zone with Highwall Indoor Unit Installation Guide

June 5, 2024
Haier

Haier logo

Haier 1422179 Ductless Single Zone with Highwall Indoor Unit

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit

Thank will help you for pure get the best purchasing this Haier performance from your product. This installation manual w heat pump.
For future reference side of ye, recolor air-conditioned the model and serial number locat/heat pump, and the date one of pure label on chase.
Swarrtaple your pry service of pure if needed. chase to this manual to aid in obtaining
To register your new Haier Duct Free System go to
https://www.haierductless.com/product-registration and input the model/serial number information on this page. To receive a 10-year compressor and parts warranty, registration is required within 60 days of installation.
49-7835 Rev. 8

Model number
Serial number
___ Date of purchase

IMPORTANT SAFETY INFORMATION

For Split-System Units:

IMPORTANT – This product** has been designed and manufactured to meet ENERGY STAR criteria for energy efficiency when matched with appropriate coil components.
However, proper refrigerant charge and proper airflow are critical to achieving rated capacity and efficiency. Installation of this product should follow the manufacturer’s refrigerant charging and airflow instructions. Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life.

** ENERGY STAR LISTED MODELS

1U09ES2VHA| 1U12ES2VHA| 1U18ES2VHA| 1U24ES2VHA|
1U09AP2VHA| 1U12AP2VHA| 1U15AP2VHA| 1U18AP2VHA| 1U24AP2VHA
1U09EH2VHA| 1U12EH2VHA| 1U18EH2VHA| |
1U09EH2VHD| 1U12EH2VHD| 1U18EH2VHD| |
1U09EH2VHE| 1U12EH2VHE| 1U18EH2VHE| |

WARNING For your safety; the information in this manual must be followed to minimize the risk of fire, electric shock, or personal injury.

  • Use this equipment only for its intended purpose as described in this manual.

  • This heat pump must be properly installed in accordance with these instructions before it is used.

  • All wiring should be rated for the amperage value listed on the rating plate. Use only copper wiring.

  • All electrical work must be completed by a qualified electrician and completed in accordance with local and national building codes.

  • Any servicing must be performed by a qualified individual.
    For any service which requires entry into the refrigerant sealed system, Federal regulations require that the work is performed by a technician having a Class II or Universal certification.

  • All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal.
    If you are getting rid of an old product with refrigerants, check with the company handling disposal.

  •  These R-410A heat pumps systems require that contractors and technicians use tools, equipment and safety standards approved for use with this refrigerant.
    DO NOT use equipment certified for R22 refrigerant only.
    WARNING RISK OF ELECTRIC SHOCK. Could cause injury or death.

  • An adequate ground is essential before connecting the power supply.

  • Disconnect all connected electric power supplies before servicing.

  • Repair or replace immediately all electrical wiring that has become frayed or otherwise damaged. Do not use wiring that shows cracks or abrasion damage along its length or at either end.
    WARNING RISK OF FIRE. Could cause injury or death.

  • Do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

INSTALLATION INSTRUCTIONS

FOR MORE HELP, VISIT HAIERAPPLIANCES.COM OR CALL THE CONSUMER HELPLINE AT 877-337-3639.

BEFORE YOU BEGIN
Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to installer – Be sure to leave these instructions with the Consumer.
  • Note to consumer – Keep these instructions for future reference.
  • Skill level – A licensed certified technician (to handle refrigerant R-410A, recovery, etc) and a qualified electrician are required for installation and service of this split heat pump system.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the limited warranty.
  • For personal safety, this system must be properly grounded.
  • Protective devices (fuses or circuit breakers) acceptable for installation are specified on the nameplate of each unit.
  • Make sure to minimize wiring or plumbing inside the wall when installing.

CAUTION

  • Aluminum building wiring may present special problems – consult a qualified electrician.

  • When the unit is in the STOP position, there is still voltage to the electrical controls.
    Required Tools for Installation

  • 14/4 AWG stranded wire

  • 5/8” (16mm), 7/8” (22mm), 1” (25mm) or adjustable wrench

  • R-410A refrigerant*

  • Adhesive tape

  • Conduit cable clamp ½”*

  • Copper line set (for size, see table on page 15)

  • 2 phillips screwdriver

  • Drill

  • R-410A flaring tool

  • Hex wrench

  • Hole saw 2 1/4”

  • Insulation*

  • Refrigerant scale

  • Level

  • Manifold gauge set

  • Measuring tape

  • Micron gauge

  • Mini-split adapter (5/16”F to 1/4”M)

  • Nitrogen*

  • Pipe cutter

  • PVC pipe (optional)

  • Razor knife

  • Reamer

  • Saddle clamp (L.S.) w/ screws

  • Sealant, non-expanding (for lineset hole)

  • Soap/water solution* or gas leakage detector

  • Stud finder

  • Torque wrench

  • Vacuum pump

  • Wire strippers

  • All usual and customary HVAC hand and power tools, meters, and testing devices
    consumable

MINIMUM CLEARANCES

(Appearance may vary)
This picture is for reference only. Your product may look different. Read your manual before installation. Explain the operation of the unit to the user according to this manual.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-1

Marketing Model Number| X1(inch)| X2(inch)| Y(inch)| Z(inch)
---|---|---|---|---
1U09EH2VHA| 4.53| 4.53| 23.23| 12.95
1U12EH2VHA
1U18EH2VHA| 5.12| 5.12| 25.98| 15.75
1U24TE2VHA
1U24AP2VHA
1U18EH2VHD
1U18LC2VHA| 4.53| 4.53| 22.95| 12.60
1U12LC2VHA| 5.47| 5.51| 19.69| 10.20
1U09TE1VHA
1U12TE1VHA
1U18TE2VHA| 5.16| 5.16| 24.72| 14.53
1U15AP2VHA
1U18AP2VHA
1U09EH2VHD
1U12EH2VHD
1U09AP2VHA| 5.12| 5.91| 19.69| 12.20
1U12AP2VHA
1U09TE2VHA| 5.12| 6.30| 20.08| 12.32
1U12TE2VHA

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-2

Step 1 – Preparation

Select the Outdoor location:

  • Choose a level place solid enough to bear the weight and vibration of the OD unit and where the operation noise will not be amplified.

  • Choose a location where the hot air discharge and/or noise will not create a nuisance for neighbors.

  • Ensure there is sufficient space to maneuver the OD unit into place.

  • Ensure there is sufficient space and no obstructions for the air inlet and outlet.

  • Install the unit’s power/communication wiring at least 10 feet away from television and radio sets to prevent interference.

  • Ensure any moisture sensitive items are kept away from the condensate drain path of the OD unit.
    NOTES:

  • OD unit cannot hang from a ceiling or be stacked.

  • Ensure that accumulated snow and debris will not block the air inlet or the coil if installing the outdoor unit with a fence or guard rail around it.

  • Ensure ventilation in case of refrigerant leakage.
    R- 410A is a safe, nontoxic, and nonflammable refrigerant.

  • Avoid installing the OD unit where corrosive gases, such as sulfur oxides, ammonia, and sulfurous gas are produced. Consult with an installation specialist about using a corrosion-proof or anti-rust additive to protect the unit coils.

Step 2 – Installation of the Indoor Unit

Proper Installation for Drainage

Set the unit on mount or pad using team lift.
Do not install the drain elbow if the unit is located in an area where freezing can occur.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-4

A. Select the Indoor location:

  • Do not allow any heat or steam near the unit.

  • Select a location where there are no obstacles in front of the unit.

  • Make sure that condensate drainage can be conveniently routed away.

  • Do not install near a doorway.

  • Ensure that the space around the left and right of the unit is more than 4”. The unit should be installed as high on the wall as possible but allow a minimum of 4” from the ceiling.

  • Use a stud finder to locate and mark stud locations for mounting and to prevent unnecessary damage to the wall.

  • Install in a location that is strong enough to withstand the full weight and vibration of the unit.

  • Leave enough space to allow access for routine maintenance.

  • Select a location that gives easy access to removing and cleaning air filters.

  • Install in a location that is 3 ft. or more away from other electrical appliances, such as televisions and audio devices.
    B. Install the Mounting Plate

  • Remove plastic bag, tape, and mounting plate from the back of the indoor unit.

  • Place the mounting plate on the wall in the desired location taking into account the minimum clearances necessary for proper operation.

  • Using a level, verify that the mounting plate is horizontal and mark the screw locations.

  • Attach the mounting plate to the wall with the supplied screws.

  • Wall anchors are supplied if not able to align all screw holes with studs.

  • Be sure that the mounting plate has been attached firmly and that applied weight is evenly distributed by each screw. (At least one screw in wall stud, others can use wall anchors.)

  • The piping for the indoor unit may be routed to and from the unit in one of several directions: left, left rear, right, right rear, or right below. See Illustration on page 7.

  • Knockouts are provided on the unit case for Left, Right, and Right Below usage.
    C. Install the Tubing

  • Measure and mark the location where the piping hole is to be drilled.

  • Follow these steps to move the drain pipe if the pipe location will be on the left side of the unit.

    1. Remove the stopper in the left drain hole and knockout the molded plug inside the port.
    2. Transfer the corrugate drain hose from the right side to the left side.
    3.  Insert stopper into right side drain port. Using soap as a lubricant and a small screwdriver will allow for easier seating of the stopper.
  • Drill the lineset hole using a 2 1/4” hole saw. Angle the drill with a downward pitch to the outside wall so that the outside wall hole will be at least a ¼” lower than the inside hole. This allows for proper drainage of condensate.

  • Install the lineset hole flange at the hole opening on the inside wall.

NOTE: The flange is prescored. It may be necessary to modify the flange to fit properly behind the wall unit housing.

D. Electrical Connections for the Indoor Unit
NOTE: Be certain all wiring complies with local building codes and NEC and that the supply voltage for this system is correct.

  • Place the indoor unit on a solid work surface before making electrical connections.
  • Both the outer plastic and inner galvanized steel cover plates must be removed to make the electrical connections for the indoor unit.
  • Raise the front cover to access the screws for removing these covers.Haier 1422179 Ductless Single Zone with Highwall Indoor Unit-5
  • Route the 14/4 AWG wiring through the slot in the back of the unit and into the front access panel.
  • Using a wire stripper, remove the insulation and separate the 4 wires.
  • Make wiring connections at each terminal according to wiring diagram. Take note of the color of the wire at each terminal and ensure the wires are connected to the outdoor unit accordingly.
  • Ensure each wire is under the screw terminal plate and the plate is tightened.
  • Ensure the 14/4 cable is secured under the strain relief bracket.
  • After the terminal block wiring is completed, replace both cover plates and lower the front casing.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-6

E. Mount Indoor Unit to Mounting Plate

  • Bundle the refrigerant piping, drain piping, and wiring with tape and carefully rout the bundle through the piping hole.
  • With the top of the indoor unit closer to the wall, hang the indoor unit on the upper hooks of the mounting plate. Slide the unit slightly side to side to verify proper placement.
  • Rotate the lower portion of the indoor unit to the mounting plate, and lower the unit onto the lower hooks of the mounting plate. (see illustration)
  • Verify the unit is secured and flush to the wall.
  • Indoor Unit installation is finished at this time.

F. Condensate Drainage Pipe

  • Verify the condensate drain line has a constant pitch downward for proper water flow. There should be no kinks or rises in the tubing which may cause a trapping effect of the water (see illustration).
    Optional: Can use PVC pipe by connecting a 1” ID PVC pipe to the drain line coming out of the wall and running to desired location.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-8

G. To Remove the Indoor Unit

  • Slightly raise the entire unit.
  • Pull the lower portion of the unit off the lower hooks and pull slightly away from the wall.
  • Lift the upper portion of the unit off the upper hooks.
Wall Brackets

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-9

Capacity (BTUh) Bracket Style Part Number Factory Reference Number
07K/09K/12K 35N/35T/40N WJ65X23038/WJ65X23240/WJ65X23038

10101275/10103071/10101275
15K/18K| 50N/50T/70N| WJ65X23251/WJ65X23251/WJ65X23056| 10102598/10102598/10102740
24K| 70N/70T| WJ65X23056/WJ65X23056| 10102740/10102740
30K/36K| 100N| WJ65X22785| 10103059
09K/12K| 35F/50F| WJ65X27875/WJ65X25594| 10103620B/10104861
18K| 70F| WJ65X26113| 10104864

Step 3 – Installation of the Outdoor Unit

A. Prepare the Outdoor Unit for Installation

  • Remove all packaging.

  • Place supplied vibration pads onto outdoor unit’s feet.

  • Attach the supplied drain elbow to the outdoor unit if required. Connect extension piping as needed (not supplied). (see illustration) NOTE: The drain elbow is designed with an air gap and will not sit flush to bottom of the outdoor unit.
    NOTE: 1U09AP, 1U12AP, 1U15AP, 1U18AP and 1U24AP* models will not use a drain elbow. A 3rd party pan is needed if condensate management is required by code.

  • Remove the cover plate of the outdoor unit to expose the terminal block connections.

  1. Remove Screw
  2. Slide the panel down to release the clips and pull away.

B. Electrical Connections for the Outdoor Unit

WARNING
RISK OF ELECTRIC SHOCK.
Could cause injury or death.
Make sure power is off before touching wires.

NOTE: Be certain all wiring complies with local building codes and NEC and that the supply voltage for this system is correct.

  • Connect the wiring for both the power source and the indoor wiring using a conduit cable bracket on the side of the outdoor unit.
  • Using a wire stripper, remove the insulation and separate the wires.
  • Verify that the wiring connections match the indoor connections wire for wire.
  • Ensure each wire is under the screw terminal plate and the plate is tightened.
  • Ensure the 14/4 control cable is secured under the strain relief bracket.
  • Verify that all connections are secured

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-13

NOTE: Failure to follow the wiring guidelines can result in control board damage and communication issues (E7 error code). This includes improper wire size, use of solid core wire, midline splicing and poor terminal connections.

C. Install Copper Lineset

  • The standard line set length is 25 feet. If the installation length is different, adjust the refrigerant charge by adding 0.2 oz/ft if the liquid line is 1/4”, or 0.5 oz/ft if the liquid line is 3/8”.

  • See table on page 15.

  • Cut the line set to length.

  • Place nut over the pipe and then flare with the R- 410A flaring tool.
    NOTE: Follow standard practices for creating pipe flares. When cutting and reaming the tubing, use caution to prevent dirt or debris from entering the tubing. Remember to place nut over the tubing before flaring.

  • To join the line set, directly align the tubing flare to the fitting on the other pipe. Slide the nut onto the fitting and hand tighten.

  • Torque the fittings according to the specifications shown in the torque chart below.
    Forced fastening without careful centering may damage the threads and cause a refrigerant leak.Pipe Diameter(ǿ)| Fastening torque
    ---|---
    Liquid side 6.35mm(1/4″)| 18N.m/13.3Ft.lbs
    Liquid/Gas side 9.52mm(3/8″)| 42 N.m/30.1Ft.lbs
    Gas side 12.7mm(1/2″)| 55N.m/40.6Ft.lbs
    Gas side 15.88mm(5/8″)| 60 N.m/44.3Ft.lbs

Two wrenches are required to join the flare connection; one standard wrench and one torque wrench adjusted to the proper settings.

  • Repeat the process for attaching the other end of the line set.
    D. Leak Test

  • Remove the cap on the service valve.

  • Using a tank of dry nitrogen and approved regulator, charge the system with 150 psig of dry nitrogen using mini split adapter to connect the valve.

  • Check for leaks at the flare fittings using soap bubbles or another detection device. If a leak is detected, make repairs to the fittings and recheck. If no leaks are detected within 3 minutes, proceed.

  • Using the same tank/regulator, charge the system to 300 psig.

  • Check for leaks as earlier. If no leaks are detected within 3 minutes, proceed.

  • Using the same tank/regulator, charge the system to 500 psig.

  • Check for leaks as earlier. Keep system pressurized for at least 20 minutes.

WARNING
Do not use acetylene, oxygen,compressed air or any mixture containing anything other than dry nitrogen. Use only dry nitrogen for pressure testing. Do not use mixtures of hydrogen containing refrigerant and air above atmospheric pressure for pressure testing, as they may become flammable and could result in an explosion. Refrigerant, when used as a trace gas, should only be mixed with dry nitrogen for pressurizing units.
Failure to follow these recommendations could result in death or serious injury as well as equipment or property damage.

E. System Evacuation
NOTE– Do not open service valve.

  • Attach a manifold gauge, micron gauge, and vacuum pump to the suction line port using adapter AD-87 (see illustration).
  • Evacuate the system to at least 350 microns.
  • Close the vacuum pump valve and check the micron gauge. If the gauge rises 150 microns in 60 seconds, the evacuation is incomplete or there is a leak in the system. If the gauge does not rise 150 microns in 60 seconds, the evacuation is complete.
  • Once evacuation is complete, remove the adapter and hose connection from the suction line port and replaced the cap.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-16

F. Refrigerant Charging

  • Add any additional refrigerant after evacuation using a digital scale.
    NOTE: Charge liquid only.

  • Fill out the refrigerant charge label using indelible ink.

  • Place the factory refrigerant charge found in table on page 15 in the box number 1.

  • Place the amount of additional refrigerant added in box number 2.

  • Add boxes 1 and 2 together and place the value in the sum box (D).

  • Adhere the filled out label in the proximity of the product charging port and under the outside units valve cover.

  • Write amounts on outdoor unit with permanent marker above the charging port if the label is missing.

  • Remove the cap from the liquid line valve. Using a hex wrench, open the valve, then replace and tighten the cap securly to avoid leaks.

  • Remove the cap from the suction line valve. Using a hex wrench, open the valve, then replace and tighten the cap securly to avoid leaks.

  • Wrap the line set, drain line, and 14/4 AWG wiring starting at the bottom of the bundle with an overlap type wrap until you reach the piping hole.

  • Use a sealant to seal the piping on both sides of the wall in order to prevent drafts, weather, or pests from entering the building.

This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.

Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-17

Refrigerant type: R-410A
GWP* value: 2088
GWP = global warming potential

  • The outdoor unit should be installed at least ½ mile away from the salt water, including seacoasts and inland waterways. If the unit installed from ½ mile to 5 miles away from the salt water, including seacoasts and inland waterways, please follow the installation instruction below.

  • Install the outdoor unit in a place (such as near buildings etc.) where it can be protected from sea breeze which can damage the outdoor unit.
    Haier 1422179 Ductless Single Zone with Highwall Indoor
Unit-18

  • If you cannot avoid installing the outdoor unit by the seashore, construct a protection wall around it to block the sea breeze.

  • A protection wall should be constructed with a solid material to block the sea breeze. The height and the width of the wall should be 1.5 times larger than the size of the outdoor unit. Also, allow at least 28“ (700mm) between the protection wall and the outdoor unit for air circulation to ventilate.

  • Install the outdoor unit in a place where water can drain freely.

  • If the above conditions cannot be met, contact Haier for assistance.

Step 4 – Final Check

Explaining Operation To the End User

  • Using the User Manual, explain to the user how to use the air conditioner/heat pump, (the remote controller, adding/removing the air filters, placing or removing the remote controller from the remote control holder, cleaning methods, precautions for operation, etc.)

  • Review precautions for operation.

  • Recommend that the user read the Operating Instructions carefully.
    Check Items for Test Run

  • No gas leak from linesets?

  • Are the linesets insulated properly?

  • Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block?

  • Is the connecting wiring of indoor and outdoor fixed?

  • Is condensate draining correctly?

  • Is the ground wire securely connected? Is the indoor unit securely fixed?

  • Is power source voltage correct according to local code?

  • Is there any odd noise?

  • Does the cooling temperature drop between 20-30°F?

  • Does the heating temperature raise between 35-40°F?

  • Is the room temperature display accurate?

LIMITED WARRANTY

For the product models listed on Attachment 1 (the “Product”), this Standard Limited Warranty is provided to the Original Owner of the Product:

For The Period Of: Haier Will Replace:

5 year limited parts warranty

From the date of the original purchase

| This limited warranty cover all defects in workmanship or material for the mechanical and electrical parts contained in the Product (“Defective Parts”) for a period of 5 years from the Date of Purchase. Haier will provide new or refurbished parts, or a replacement for all or part of the unit, at its sole discretion, to your licensed HVAC technician installer. This warranty also covers all defects in workmanship or material for the unit controller for a period of 1 year. The remote controller and WiFi module are covered by 1-year accessory warranty. The ductless system is covered by standard warranty. Haier will provide a new or refurbished controller, at its sole discretion.
7 year compressor warranty from the date of the original purchase| The compressor contained in this product is warrantied for a period of 7 years from the Date of Purchase. Haier will provide a new or refurbished compressor, or a replacement for all or part of the unit, at its sole discretion, to your licensed HVAC technician installer.

WHAT IS THE DATE OF PURCHASE
The “Date of Purchase” is the date that the original installation is complete and all product start-up procedures have been properly completed and verified by the installer’s invoice. If the installation date cannot be verified, then the Date of Purchase will be sixty (60) days after the manufacture date, as determined by the Product’s serial number. You should keep and be able to provide your original sales receipt from the installer as proof of the Date of Purchase. In new construction, the Date of Purchase will be the date the owner purchased the residence from the builder.

WHO IS COVERED
Owner-occupied: The “Original Owner” of this product, which means the original owner (and his or her spouse) of the residence where the Product was originally installed. Subject to the law of the state or province where the Product is installed, this warranty is not transferable to subsequent owners or if the product is moved to a different residence after the initial installation. Non-owner occupied: This limited warranty is provided for product 1) installed in a) single family or multi-family non-owner occupied residential buildings, or b) non-industrial commercial applications, (such as office buildings, retail establishments, hotels/motels) where the product is not subjected to an atmosphere with corrosives or high levels of particulates (such as soot, aerosols, fumes, grease), and 2) if the product is maintained annually by a licensed HVAC technician (proof of annual maintenance is required). The “Original Owner” of the product, means the original owner of the building where the product was originally installed. For new construction, the purchaser of the building from the builder will also be considered an original owner. This warranty is not transferable to subsequent owners or if the product is moved to a different location after the initial installation.

HOW CAN YOU GET SERVICE
Contact your licensed HVAC technician installer. All installation and service must be performed by a licensed HVAC technician. Failure to use a licensed HVAC technician for installation of this Product voids all warranty on this Product..

THIS WARRANTY DOES NOT COVER

  • Damage from improper installation.
  • Damage in shipping.
  • Defects other than from manufacturing (i.e., workmanship or materials).
  • Damage from misuse, abuse, accident, alteration, lack of proper care and/or regular maintenance, or incorrect electrical voltage or current.
  • Damage resulting from floods, fires, wind, lightning, accidents or similar conditions.
  • Damage from installation or other services performed by other than a licensed HVAC technician.
  • Labor and related services for repair or installation of the Product.
  • A Product purchased from an online retailer.
  • Damage as a result of subjecting Product to an atmosphere with corrosives or high levels of particulates (such as soot, aerosols, fumes, grease).
  • A Product sold and/or installed outside of the 50 United States, the District of Columbia, or Canada.
  • Batteries for the controller and other accessories provided with the Product for installation (e.g., plastic hose).
  • Normal maintenance, such as cleaning of coils, cleaning filters, and lubrication.
  • For Product installed in non-owner occupied applications, Product that has not been maintained annually by a licensed HVAC technician (proof required).

Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty.

10 YEAR STANDARD REGISTERED LIMITED WARRANTY
All “Indoor and Outdoor Products,” identified in Attachment 1, registered by the installer or the Original Owner within 60 days of the Date of Purchase shall receive a Standard Registered Limited Warranty, which shall be identical to the Standard Base Warranty, except that the Limited Parts Warranty shall be for a term of 10 Years and the Limited Compressor Warranty shall be for a term of 10 years. All Product not registered within 60 days of the Date of Purchase shall be subject to the Standard Base Warranty. Some states and provinces do not allow warranty terms to be subject to registration; in those states and provinces the longer terms for Limited Parts Warranty and the Limited Compressor Warranty apply.

THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies. This warranty does not cover incidental or consequential damages. Some states and provinces do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. Some states and provinces do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary by state and province. This warranty covers units within the 50 United States, the District of Columbia and Canada. This warranty it provided by GE Appliances a Haier company, Louisville, KY 40225.

ATTACHMENT 1
The “Product” is defined as Haier brand Ductless Split Units. The “Product” contains 2 sub-categories of goods: “Indoor and Outdoor Products” and “Selected Installation Products,” which are further defined below: “Indoor and Outdoor Products” can further be identified by the following model number descriptions: 1U, 2U, 3U, 4U, AB, AD, AL, AM, AW, AF, MVA MVH “Selected Installation Products,” identified by the following model number descriptions: PB- FQG-, AH1-, MS1- and MS3-*

IMPORTANT
If you have a problem with this product, please call 877-337-3639 for the name and telephone number of the nearest authorized service center.
DATED PROOF OF PURCHASE REQUIRED FOR WARRANTY SERVICE