Miele PFD 101 Dishwasher Installation Guide
- June 5, 2024
- Miele
Table of Contents
PFD 101 Dishwasher
Installation Guide
PFD 101
PFD 101 i
PFD 101 U
Installation notes
For safe installation and commissioning of the dishwasher please read the
installation plan, the service documentation, the installation sheet, and the
operating instructions.
This installation plan includes the dimensions of the appliance, the technical
data, and the requirements to be met on-site for the installation of the
dishwasher.
Installation requirements
This dishwasher must only be installed and commissioned by the Miele
Customer Service Department, a Miele authorized dealer or a suitably qualified
specialist.
Installation should only be performed in accordance with valid regulations,
relevant standards, and health and safety codes.
Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any
furniture and fittings in the room must therefore be suitable for the purpose.
Vapor barrier film for built-in appliances
All work on the electrical connection must be carried out by the Miele
Customer Service Department, an authorized Miele dealer or a qualified
electrician.
Plug connection
The dishwasher should be connected to the electricity supply via a suitably
rated plug and socket.
Hard-wired
If the dishwasher is hard-wired to the power supply, a power switch capable
of disconnecting the dishwasher at all poles must be installed on-site. This
power switch must have a contact gap of at least 3 mm.
The socket and the power switch must be accessible after the appliance has
been installed. An electrical safety test can then easily be carried out,
e.g., after any service or maintenance work. The connection cable must be
protected from the risk of thermal damage.
Residual current device (RCD)
For increased safety, it is recommended to protect the dishwasher with a
residual current device (RCD) with a trip current of 30 mA.
Equipotential bonding
There is a screw connection point for equipotential bonding at the back of
the dishwasher. Equipotential bonding should be carried out if possible on
site.
Water connection
The dishwasher must only be connected to fully vented pipework. A brief
increase in the water pressure can damage components of the dishwasher.
Water inlet
The quality of the incoming water must correspond to the drinking water
specification of the country in which the dishwasher is being operated. The
dishwasher must be connected to the water supply in strict accordance with
current local and national water authority regulations.
It can be connected to cold or hot water supplies. Connecting the dishwasher o
a hot water supply will reduceprogramme running times. For short program
running times, dynamic water pressure of at least 200 kPa is also required.
UK installation requirements:
The double check valve supplied with this product must be installed between
the stopcock and the water inlet hose. Screw the double-check valve onto the
stopcock. Then screw the water inlet hose with the water protection system
onto the thread of the double check valve.
If a stopcock is not available, only a qualified installer may connect the
dishwasher to the mains water supply.
The stopcock should remain accessible once the dishwasher has been installed
so that the water supply can be shut off whenever the appliance is not in use.
Drain
The dishwasher drain hose should be connected to a separate on-site
drainage system for the dishwasher only. If a separate connection is not
available, we recommend connecting the hose to a dual-chamber siphon.
If the hose is to be fitted directly to the drainage system on-site, use the
hose clip supplied with the dishwasher.
The on-site connector for the drain hose can be adapted to different hose
diameters. If the connector extends more than 30 mm into the drain hose, it
must be shortened. Otherwise, the drain hose can become blocked.
Lay the drain hose so that it does not kink and is not being subjected to
pressure or tension.
If the on-site drain connection is situated lower than the guide path for the
lower basket rollers in the open door, a siphoning effect during a program can
cause the wash cabinet to empty itself of water.
In this case, lay the drain hose with a bend in it so that its highest point
is at least level with the guide path for the lower basket rollers.
External dispensing
An external dispensing module for liquid cleaning agents can be connected
to the back of the dishwasher. The dispensing module is available as an
optional accessory and is
supplied with installation instructions.
Freestanding appliance
PFD 101
Built-in appliance/built-under appliance
Front panel dimensions PFD 101 i
Length | [mm] | 500–654 |
---|---|---|
Thickness | [mm] | 16–20 |
Weight | [kg] | 4–11 |
Connections on the back of the appliance
- Electrical connection
- External dispensing, power supply connection
- Equipotential bonding
- Wastewater
- Cold or hot water
- External dispensing, connection for dispensing hose sealed with a blind stopper*
- the dispenser connector is supplied with the dispensing module
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of the appliance to DOS module | [m] | 2.8 |
Length of power cable, back of the appliance to DOS module | [m] | 2.8 |
Place the container on the floor next to the cleaning machine or in an
adjacent cabinet.
The container must not be placed on top of or above the cleaning machine.
Technical data
Model PFD 101 | Version | i | U |
---|
Dimensions and weights
Height | [mm] | 845 | 805 | 805 |
---|---|---|---|---|
Height adjustment | [mm] | 35 | 65 | 65 |
Width | [mm] | 600 | 598 | 598 |
Depth | [mm] | 600 | 570 | 570 |
Depth with door open | [mm] | 1195 | 1165 | 1165 |
Max. plinth return | [mm] | – | 115 | 115 |
Weight | [kg] | 60 | 42 | 44 |
Max. floor load | [N] | 1000 | 1000 | 1000 |
Emission levels
Sound power level | [dB(A) re 1 pW] | 46 | 46 |
---|---|---|---|
The sound pressure level in the workplace | [dB(A)] | 34.1 | 34.1 |
Electrical connection
Standard electrical connection
Voltage | 3N AC 400 V | |
---|---|---|
[Hz] | 50 |
Frequency
Fuse rating| [A]| 16
Plug| | –
Power cable length| [rrl]| 1,7
Power cable cross-section| [mm2]| 5 x 2,5
Heat output| [kW]| 7,1
Total rated load| [kW]| 7,3
Possible voltage variant| |
Voltage *| | AC 230 V
Frequency| [Hz]| 50
Fuse rating| [A]| 10-16
Plug| | Typ-F
Power cable * length| [rrl]| 1,7
Power cable cross-section| [mm2]| 3 x 1,5
Heat output| [kW]| 1,9
Total rated load| [kW]| 2,1
‘ Programme running times are longer with 11 Optional accessory this voltage
variant| |
Water inlet| |
Max. water temperature| [°C]| 60
Max. water hardness| [mmo1/1]| 7.
Max. water hardness| [°dH]| 36
Water connection pressure| [kPa]| 50 -1000
On-site threaded union (flat seal)| [inches]| 3/4
Connection hose length| [m]| 2.
Connection hose extension ‘| [m]| 2.
Drain
Max. water temperature | [°C] | 82 |
---|---|---|
Drain hose length | [m] | 2. |
Max. drain hose length | [m] | 4 |
Max. delivery head | [m] | 1 |
Max. transient flow rate | [I/min] | 10 |
Hose inner diameter | [mm] | 22 |
On-site hose sleeve (0 x length) | [mm] | 22 x 30 |
Operating conditions | ||
Ambient temperature | [°C] | +5 – +40 |
Relative humidity:
Up to 31 °C, maximum Linear decreases to 40 °C| [%] [%]| 80
50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions| |
Ambient temperature| [°C]| -20 – +60
Relative humidity| [%]| 10-85
Air pressure| [h Pa]| 500-1060
Min. site access dimensions including Jansport pallet| |
Height| [mm]| 970
Width| [mm]| 670
Depth| [mm]| 670
MIELE S.A.S – Z.I. du Coudray – 9, av. Albert Einstein – B.P. 1000
93151 Le Blanc-Mesnil Cedex –
www.miele.fr/professional
R.C.S. Bobigny B 708 203 088
Contact Service Commercial
Tél. : 01 49 39 44 44 – Fax : 01 49 39 44 38 – Mail :
advpro@miele.fr
Contact SAV Professionnel (Intervention)
Tél. : 01 49 39 44 78 – Fax. : 01 49 39 34 10 – Mail :
savpro@miele.fr
Contact Support Technique (Hotline)
Tél. : 01 49 39 44 88 – Mail :
support.technique@miele.fr
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>