ITC Flexible Light Instruction Manual
- June 3, 2024
- ITC
Table of Contents
ITC Flexible Light
PARTS/TOOLS NEEDED
PARTS/TOOLS NEEDED:
| | |
Flexible Light| UL Recognized Power Supply
(purchased separately)
| Mounting Channel
(purchased separately)
| Power Drill
(not provided)
| | |
Butt Splice Connectors
(not provided)
| #4 Flat Head Screws
(not provided)
| Alcohol Wipes
(not provided)
| Primer 94
(not provided)
IMPORTANT SAFETY INSTRUCTIONS
READ CAREFULLY FOR YOUR PROTECTION AND SAVE ALL INSTRUCTIONS
- Disconnect power before installing, adding or changing any component.
- To avoid a hazard to children, account for all parts and destroy all packing materials.
- Use only with a UL-approved power supply.
INSTALLATION CONSIDERATIONS
- It is recommended that fuse protection be added to the positive (+) input.
- Do not bend lighting more than necessary. It should only be bent to a 1” radius. Bending to a tight 90° angle could cause damage to the circuit.
- Only bend the LED ribbon in one natural direction, do not try to bend in an unnatural direction such as twisting.
- Make sure surfaces are smooth, clean, and free of dust and debris before installing this product. Surfaces should be cleaned and primed per the 3M specified cleaning instructions* on page two. Failure to properly clean the surface may result in loss of adhesion.
- Rough surfaces may prevent proper adhesion. If adhesion failure occurs, screw-in mounting channels may be used for installation. Contact ITC sales for more information on mounting channels: 616-396-1355 / sales@itc-us.com.
DO NOT TWIST
DO NOT INSTALL ON ROUGH PLY-WOOD Recommend use of mounting channel TPB-1 or TPB-2.
DO NOT INSTALL ON A ROUGH EDGE Recommend use of mounting channel TPB-1 or TPB-2.
INSTALLATION INSTRUCTION
-
Clean the surface with a mixture of 50% water/50% isopropyl alcohol.
Let the surface dry. -
Apply Primer 94 as recommended by 3M.
Failure to follow the surface preparation guidelines will void the warranty. -
Remove the paper backing and firmly press the light in place.
DO NOT slide or drag your thumb along the tape light or the silicone may be pulled off. -
If using mounting channels for installation, they are available in screw or adhesive mount. Install per your desired method.
Screw Mount Channel: Screws should be used every 12”.
Adhesive Mount Channel:
Follow the same cleaning instructions above and remove the paper backing from the channel and press in place.
Both Channels:
Remove the paper backing from the light and press the light into the channel . -
Wire the light based on the wiring diagrams below.
-
Please review the considerations below to ensure a successful installation.
Flexible light cannot be field cut. Field cutting the light will void the warranty.
3030 Corporate Grove Dr. Hudsonville, MI 49426 Phone: 616.396.1355 itc- us.com.
Warranty Information
For warranty information please visit www.itc-us.com/warranty-return- policy
DOC #: 710-00127 • Rev F • 02/02/21.
References
- Register a .US.COM domain today!
- Surface Preparation for 3Mâ„¢ VHBâ„¢ Tape Applications
- ITC Warranty & Return Policy
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>