BOSCH GLM 100 C Professional Laser RangeFinders Instruction Manual
- June 5, 2024
- Bosch
Table of Contents
- BOSCH GLM 100 C Professional Laser Range Finders
- Product Description and Specifications
- Technical Data
- Product Features
- Assembly
- Operation
- Measuring Procedure
- Selecting the Reference Level
- Basic Settings
- Measuring Functions
- Simple Length Measurement
- Area Measurement
- Volume Measurement
- Indirect Distance Measurement
- Wall Surface Measurement
- Grade Measurement
- Timer Function
- List of the last Measuring Values
- Deleting Measured Values
- Adding Measured Values
- Subtracting Measured Values
- Data Transmission to other Devices
- Deactivating the Bluetooth ® Interface
- Data Transmission via USB Interface
- Working Advice
- Maintenance and Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BOSCH GLM 100 C Professional Laser Range Finders
Safety Notes
Working safely with the measuring tool is possible only when the operating and safety information are read completely and the instructions contained therein are strictly followed. Never make warning labels on the measuring tool unrecognizable. SAVE THESE INSTRUCTIONS.
Caution
-
The use of other operating or adjusting equipment or the application of other processing methods than those mentioned here, can lead to dangerous radiation exposure.
-
The measuring tool is provided with a warning label.
-
If the text of the warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.
-
Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself. This measuring tool produces laser class 2 laser radiation according to IEC 60825-1. This can lead to persons being blinded.
-
Do not use the laser viewing glasses as safety goggles. The laser viewing glasses are used for improved visualization of the laser beam, but they do not protect against laser radiation
-
Do not use the laser viewing glasses as sun glasses or in traffic. The laser viewing glasses do not afford complete UV protection and reduce color perception.
-
Have the measuring tool repaired only through qualified specialists using original spare parts. This ensures that the safety of the measuring tool is maintained.
-
Do not allow children to use the laser measuring tool without supervision. They could unintentionally blind other persons or themselves.
-
Do not operate the measuring tool in explosive environments, such as in the presence of flammable liquids, gases or dusts. Sparks can be created in the measuring tool which may ignite the dust or fumes
-
Protect the measuring tool against heat, e.g., against continuous intense sunlight, fire, water, and moisture. Danger of explosion
-
In case of damage and improper use of the battery, va- pours may be emitted. Ventilate the area and seek medical help in case of complaints. The vapors can irritate the respiratory system.
Caution!
- When using the measuring tool with Blue- tooth ®, interference with other devices and systems, airplanes and medical devices (e.g., cardiac pacemakers, hearing aids) may occur. Also, the possibility of hu- mans and animals in direct vicinity being harmed can- not be completely exempt. Do not use the measuring tool with Bluetooth ® in the vicinity of medical devices, petrol stations, chemical plants, areas where there is danger of explosion, and areas subject to blasting. Do not use the measuring tool with Bluetooth ® in air- planes. Avoid operation in direct vicinity of the body over longer periods.
- The Bluetooth ® word mark and logos are registered trade- marks owned by Bluetooth SIG, Inc. and any use of such marks by Robert Bosch Ltd. is under license.
Safety Warnings for Battery Chargers
Keep the battery charger away from rain or moisture. Penetration of water in the battery charger increases the risk of an electric shock.
- Only charge Bosch lithium ion batteries or lithium ion batteries installed in Bosch products. The battery volt- age must match the battery charging voltage of the charger. Otherwise there is danger of fire and explosion. Keep the battery charger clean. Contamination can lead to danger of an electric shock.
- Before each use, check the battery charger, cable and plug. If damage is detected, do not use the battery charger. Never open the battery charger yourself.
- Have repairs performed only by a qualified technician and only using original spare parts. Damaged battery chargers, cables and plugs increase the risk of an electric shock.
- This battery charger can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the battery charger in a safe way and understand the hazards involved. Other- wise, there is danger of operating errors and injuries.
- Supervise children. This will ensure that children do not play with the charger.
- Cleaning and user maintenance of the battery charger shall not be made by children without supervision.
Products sold in GB only our product is fitted with a BS 1363/A approved
electric plug with internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be cut off and
an appropriate plug fitted in its place by an authorized customer service
agent. The replacement plug should have the same fuse rating as the original
plug.
The severed plug must be disposed of to avoid a possible shock hazard and
should never be inserted into a mains sock- et elsewhere.
Product Description and Specifications
Intended Use
The measuring tool is intended for measuring distances, lengths, heights,
clearances, grades and for the calculation of areas and volumes. The measuring
tool is suitable for measuring indoors and outdoors.
The measuring results can be transmitted to other devices via Bluetooth ®
and USB data port (not when operating the measuring tool in the R60
Professional measuring rail).
Technical Data
Article number | 3 601 K72 7.. |
---|---|
Distance measurement | |
Measuring range (max.) | 100 mA) |
Measuring range (typical) | 0.05 –80 mB) |
Measuring range (typical under unfavourable conditions) | 45 m C) |
Measuring accuracy (typical) | ±1.5 mmB) |
Measuring accuracy (typical under unfavourable conditions) | ±2.5 mmC) |
Lowest indication unit | 0.1 mm |
Indirect Distance Measurement and Vial | |
Measuring range | –60° –+60°D) |
Grade measurement | |
Measuring range | 0° –360° (4×90°)D) |
Measuring accuracy (typical) | ±0.2° E)/G) |
Lowest indication unit | 0.1° |
General | |
Operating temperature | –10 °C…+50 °CF) |
Storage temperature | –20 °C…+50 °C |
Allowable charging temperature range | +5 °C…+40 °C |
Relative air humidity, max. | 90 |
Laser class | 2 |
Laser type | 635 nm, 1 mW |
Laser beam diameter (at 25 °C) approx.
– at 10 m distance
– at 80 m distance
| ****
6 mm 48 mm
Setting accuracy of the laser to the housing, approx.
– Vertical
– Horizontal
| ±2 mm/m G)
±10 mm/mG)
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
| ****
20 s 5 min
Weight according to EPTA-Procedure 01/2003| 0.14 kg
Dimensions| 51 x 111 x 30 mm
Degree of protection| IP 54 (dust and splash water protected)
Data transmission|
Bluetooth ®| Bluetooth ® 4.0 (Classic and Low Energy) I)
Micro USB cable
– Charging voltage
– Charging current
| USB 2.0
5.0 V 500 mA
Battery| Li-Ion
Rated voltage| 3.7 V
Capacity| 1.25 Ah
Number of battery cells| 1
Single measurements per battery charge, approx.| 25000H)
Battery Charger|
---|---
Article number| 2 609 120 4..
Charging time| approx. 3 h
Output voltage| 5.0 V|
Charging current| 500 mA
Protection class| /II
- For measurements from the rear measuring-tool edge, the operating range increases the better the laser light is reflected from the surface of the target (dispersive, not reflective) and the brighter the laser point is with respect to the ambient brightness (indoors, twilight). For distances greater than 80 m, we recommend using a retroreflective target plate (accessory). For distances below 20 m, a retroreflective target plate should not be used, as it can lead to measuring
- For measurements from the rear measuring-tool edge, 100 reflectance of the target (e.g., a white-painted wall), weak backlight and 25 °C operating Additionally, a deviation influence of ±0.05 mm/m must be taken into account.
- For measurements from the rear measuring-tool edge, 10 –100 reflectance of the target, strong backlight and –10 °C to +50 °C operating tem- Additionally, a deviation influence of ±0.29 mm/m must be taken into account.
- For measurements with the rear side of the unit as reference, the measuring range is ±60 °
- After calibration at 0 ° and 90 ° with an additional grade error of ±0.01 ° /degree to 45 ° (max.).
- In the continuous measurement function, the maximum operating temperature is +40 °C.
- At 25 °C operating temperature
- For a new and charged battery without display illumination, Bluetooth ® and tone
- For Bluetooth ® low-energy-devices, establishing a connection may not be possible, depending on model and operating Bluetooth ® devices must support the SPP profile.
Please observe the article number on the type plate of your battery charger. The trade names of individual battery chargers may vary. Please observe the article number on the type plate of your measuring tool. The trade names of the individual measuring tools may vary. The measuring tool can be clearly identified with the serial number 20 on the type plate.
Product Features
The numbering of the product features shown refers to the il- lustration of the measuring tool on the graphic page.
-
Display
-
Measuring button
-
Button for grade measurement /calibration **
-
Button for clearing the internal memory /On/Off **
-
Minus button
-
Button for result /timer function **
-
Button for measured-value list /storage of constant **
-
Button for function mode /basic settings **
-
Positioning pin
-
Button for selection of the reference level
-
Plus button
-
Button for length, area and volume measurement
-
Bluetooth ® button
-
Cover, micro USB port
-
Micro USB port
-
Fixture for carrying strap
-
Reception lens
-
Laser beam outlet
-
1/4″thread
-
Serial number
-
Laser warning label
-
QR-Code (product information)
-
Charge connector
-
Battery charger
-
Micro USB cable
-
Protective pouch
-
Measuring rail *,***
-
Locking lever for measuring rail
-
Tripod*
-
Laser viewing glasses*
-
Laser target plate*
- The accessories illustrated or described are not included as standard delivery.
** Keep button pressed to call up the extended functions.
***When operating the measuring tool in the measuring rail 27, data transmission is not possible.
Display Elements
- Measured-value lines
- ERROR indication
- **** Result line
- Digital vial /position of measured-value list entry
- Measured-value list indicator
- Measuring functions
Length measurement
Area/surface measurement
Volume measurement
Continuous measurement
Indirect height measurement
Double indirect height Measurement
Indirect length measurement
Timer Function
Wall-surface measurement
Grade Measurement
- Battery charge-control indicator
- Laser, switched on
- Measurement reference level
- Temperature warning
- Bluetooth ® switched on Bluetooth ® activated, connection established . Bluetooth ® activated, no connection established
- Charging procedure
- Slow charging procedure
The Bluetooth ® word mark and logos are registered trade- marks owned by Bluetooth SIG, Inc. and any use of such marks by Robert Bosch Ltd. is under licens
Declaration of Conformity
We declare under our sole responsibility that the product de- scribed under Technical Data is in conformity with the following standards or standardization documents
EN 61010-1 2010, EN 60950-1 2006+A11 2009+
A1 2010+A12 2011+AC 2011, EN 60825-1 2007,
EN 61326-1 2006-05, EN 300 328 2012-06,
EN 301 489-1 2008-04, EN 301 489-1 2011-09,
EN 301 489-17 2012-09, EN 62479 2010-09 and
EN 60335 (battery chargers) according to the provisions of the directives
2011/65/EU, 2004/108/EC, 1999/5/EC.
Technical documents at Robert Bosch GmbH, PT/ETM9, D-70745 Leinfelden
Echterdingen Henk Becker Executive Vice President Engineering
Helmut Heinzelmann
Head of Product Certification PT/ETM9
Robert Bosch GmbH, Power Tools Division D-70745 Leinfelden-Echterdingen
19.04.2013
Assembly
Battery Charging
- Do not use a different battery charger. The battery charger provided is matched to the lithium ion battery in- stalled in your measuring tool.
- Observe the mains voltage! The voltage of the power source must correspond with the data on the type plate of the battery charger.
Note:-
The battery is supplied partially charged. To ensure full battery capacity,
completely charge the battery in the charger before using for the first time.
The lithium ion battery can be charged at any time without reducing its
service life. Interrupting the charging procedure does not damage the battery.
When the bottom segment of the battery charge-control indicator g flashes,
only a few more measurements can be carried out. Charge the battery.
When the frame around the segments of the battery charge- control indicator
g flashes, measurements are no longer possible. Continued use of the
measuring tool is only possible for a short period (e.g., for checking entries
in the measured-value list, performing a calculation, etc.). Recharge the
battery.
The charge procedure begins as soon as the mains plug of the battery charger
is plugged into the socket outlet and the charge connector 23 is plugged
into socket 15.
The battery charge-control indicator g indicates the charging progress.
During the charging procedure, the segments flash one after the other. When
all segments of battery charge-control indicator g are displayed, the
battery is completely charged.
Disconnect the battery charger from the mains supply when not using it for
longer periods.
Additionally, the battery can also be recharged via a USB port. For this,
connect the measuring tool to a USB port using the micro USB cable. In USB
operation (recharging, data trans- mission), the charging duration n can
be significantly pro- longed.
The measuring tool cannot be used independently during the charging procedure.
Usage is possible only in combination with a USB connection and the available
software.
The Bluetooth ® function switches off during the charging procedure.
Existing connections to other devices are interrupt- ed. This can lead to data
loss.
- Protect the battery charger against moisture!
Notes for Optimum Handling of the Battery in the Measuring Tool
Store the measuring tool only within the allowable tempera-ture range, see
“Technical Data”. As an example, do not leave the measuring tool in a vehicle
in summer.
A significantly reduced working period after charging indi-cates that the
battery is used and must be replaced.
Observe the notes for disposal.
Operation
Initial Operation
- Do not leave the switched on measuring tool unattended and switch the measuring tool off after use. Other persons could be blinded by the laser beam.
- Protect the measuring tool against moisture and direct sun light.
- Do not subject the measuring tool to extreme temperatures or variations in temperature. As an example, do not leave it in vehicles for long time. In case of large varia- tions in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. In case of extreme temperatures or variations in tempera- ture, the accuracy of the measuring tool can be impaired.
- Avoid heavy impact to or falling down of the measuring tool. After severe exterior effects to the measuring tool, it is recommended to carry out an accuracy check each time before continuing to work).
Switching On and Off
For switching on the measuring tool, the following possibilities are given
- Press the On/Off button 4 The measuring tool is switched on and is in length measurement The laser is not activated.
- Pressing the measuring button 2 Measuring tool and laser are switched on. The measuring tool is in length measurement mode. When the measuring tool is inserted in the measuring rail 27 , the grade measurement function is activated
- Do not point the laser beam at persons or animals and do not look into the laser beam yourself, not even from a large distance.
To switch off the measuring tool, press the On/Off button 4 for a few
seconds.
When no button on the measuring tool is pressed for approx. 5 minutes, the
measuring tool automatically switches off to save the batteries/rechargeable
batteries.
When the angle is not changed for approx. 5 minutes when in the Grade
measurement operating mode, the measuring tool automatically switches off to
save the batteries/re- chargeable batteries.
When switching off automatically, all stored values are retained.
Measuring Procedure
When the measuring tool is inserted in the measuring rail 27 , it is
always in the length measurement or grade measurement function after switching
on by pressing the measuring button
Other measuring modes can be switched to by pressing the respective
function/mode button.
After switching on, the rear edge of the measuring tool is pre- set as the
reference level for the measurement. By pressing the reference level button
10 , the reference level can be changed.
Place the measuring tool with the selected reference plane against the desired
starting point of the measurement (e.g. a wall).
Briefly press the measuring button 2 to switch on the laser beam.
- Do not point the laser beam at persons or animals and do not look into the laser beam yourself, not even from a large distance.
Aim the laser beam at the target surface. Briefly press the measuring button
2 again to imitate the measurement.
When the laser beam is switched on permanently, the Typically, the measured
value appears after 0.5 and latest after 4 seconds. The duration of the
measurement depends on the distance, the light conditions and the reflection
proper- ties of the target surface. The end of the measurement is indicated by
a signal tone. The laser beam is switched off auto- metrically upon completion
of the measurement.
When no measurement takes place approx. 20 seconds after collimating, the
measuring tool automatically switches off to save the battery.
Selecting the Reference Level
For the measurement, you can select between four reference planes
- The rear edge of the measuring tool or the front edge of the 90° folded-out positioning pin 9 (e. when measuring on- ward from outer corners),
- The tip of the 180° folded-out positioning pin 9 (e.g. when measuring from a corner),
- The front measuring-tool edge (e.g. when measuring on- ward from a table edge),
- The Centre of thread 19 (e. for tripod measurements).
To select the reference level, press button 10 until the re- quested
reference level is indicated on the display. Each time after switching on the
measuring tool, the rear end of the measuring tool is preset as the reference
level.
Subsequent changing of the reference level for measurements that have already
been carried out (e.g. when indicating measuring values in the measured-value
list) is not possible.
Basic Settings
To access the Basic settings menu, press and hold the basic settings button
8.
Briefly press the basic settings button 8 to select the individual menu
items.
Press the minus button 5 or the plus button 11 to select the setting
within the menu items.
To exit the Basic settings menu, press the measurement button 2.
Basic Settings
Tone Signals
- On
- Off
With exception of the Permanent laser beam setting, all ba- sic settings are retained when switching off.
Continuous Laser Beam
- Do not point the laser beam at persons or animals and do not look into the laser beam yourself, not even from a large distance.
In this setting, the laser beam also remains switched on between measurements for measuring, it is only required to press the measuring button 2 once.
Measuring Functions
Simple Length Measurement
For length measurements, press button 12 until the length measurement
indication appears on the display.
To switch the laser on and for measuring, briefly press the measuring button
2 once each time.
The measured value is displayed in the result line c.
For several subsequent length measurements, the last measured results are
displayed in the measured-value lines a.
Area Measurement
For area/surface measurements, press button 12 until the indicator for
area measurement appears on the display.
Afterwards, measure the length and the width, one after an- other, in the same
manner as a length measurement. The laser beam remains switched on between
both measurements.
Upon completion of the second measurement, the surface is automatically
calculated and displayed in the result line c. The individual measured
values are displayed in the measured-value lines a.
Volume Measurement
For volume measurements, press button 12 until the indicator for volume
measurement appears on the display. Afterwards, measure the length, width and
the height, one after another, in the same manner as for a length measurement.
The laser beam remains switched on between all three measurements.
Upon completion of the third measurement, the volume is automatically
calculated and displayed in the result line c. The individual measured
values are displayed in the measured-value lines a.
Values above 1000000 m3 cannot be indicated; “ERROR” appears on the display.
Divide the volume to be measured in-to individual measurements; their values
can then be calculated separately and then summarized.
Continuous Measurement (Tracking) / Minimum/Maxi-mum Measurement
For continuous measurements, the measuring tool can be moved relative to the
target, whereby the measuring value is updated approx. every 0.5 seconds. In
this manner, as an ex-ample, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, press function mode button 8 until the indicator
for continuous measurement appears on the display. To start the continuous
measurement, press the measuring button 2.
The minimum measurement is used to determine the shortest distance from a
fixed reference point. It is used, as an example, for determining plumb lines
or horizontal partitions. The maximum measurement is used to determine the
greatest distance from a fixed reference point. It is used, as an example, for
determining diagonals.
The current measuring value is displayed in the result line c. The maximal
(“max”) and the minimal (“min”) measuring value are displayed in the measured-
value lines a. It is always overwritten, when the cur-rent length measurement
value is less than the present minimal or larger than the present maximal
value.
The previous minimal and maximal values are deleted by pressing the button for
clearing the internal memory 4. Pressing the measuring button 2 ends the
continuous
measurement. The last measured value is displayed in the result line c.
Pressing the measuring button 2 again restarts a continuous measuring run.
Continuous measurement automatically switches off after 5 min. The last
measured value remains indicated in the result line c.
Indirect Distance Measurement
Note: Indirect distance measurement is always less accurate than direct
distance measurement. Depending on application, greater measuring errors are
possible than with direct distance measurement. To improve the measuring
accuracy, we recommend using a tripod (accessory).
The indirect distance measurement is used to measure distances that cannot be
measured directly because an obstacle would obstruct the laser beam or no
target surface is available as a reflector. This measuring procedure can only
be used in vertical direction. Any deviation in horizontal direction leads to
measuring errors.
The laser beam remains switched on between the individual measurements.
For indirect length measurements, three measuring modes are available. Each
measuring mode can be used for deter-mining different distances.
-
Indirect height measurement
Press the function-mode button 8 until the indication for indirect height measurement 1 appears on the display.
Pay attention that the measuring tool is positioned at the same height as the bottom measuring point. Now, tilt the measuring tool around the reference plane and measure distance “1” as for a length measurement
Upon completion of the measurement, the result for the sought distance “X” is displayed in the result line c. The measuring values for the distance “1” and the angle “α”are displayed in the measured-value lines a. -
Double indirect height measurement
Press the function-mode button 8 until the indication for dou1ble indirect height measurement appears on the display
Measure distances “1” and “2” in this sequence as for a length measurement.
Upon completion of the measurement, the result for the sought distance “X” is displayed in the result line c. The measuring values for the distances “1”, “2” and the angle “α” are displayed in the measured-value lines a.
Pay attention that the reference plane of the measurement (e.g. the rear edge of the measuring tool) remains exactly at the same location for all individual measurements within a measuring sequence. -
Indirect length measurement
Press the function-mode button 8 until the indication for indirect length measurement 1 appears on the display.
Pay attention that the measuring tool is positioned at the same height as the sought measuring point. Now, tilt the measuring tool around the reference plane and measure distance “1” as for a length measurement.
Upon completion of the measurement, the result for the sought distance “X” is displayed in the result line c. The measuring values for the distance “1”and the angle “α” are displayed in the measured-value lines a.
Wall Surface Measurement
The wall surface measurement is used to determine the sum of several
individual surfaces with a common height .In the example shown, the total
surface of several walls that have the same room height A, but different
lengths B, are to be determined.
For wall surface measurements, press the function-mode but-ton 8 until the
indicator for wall surface measurement appears on the display.
Measure the room height A as for a length measurement. The measured value (“c
s t”) is displayed in the top measured-value line a. The laser remains
switched on.
Afterwards, measure length B1 of the first wall. The surface is automatically
calculated and displayed in the result line c. The length measurement value is
dis-played in the center measured-value line a. The laser remains switched on.
Now, measure length B2 of the second wall. The individually measured value
displayed in the center measured-value line a is added to the length B1. The
sum of both lengths (“sum”, displayed in the bottom measured-value line a) is
multi-plied with the stored height A. The total surface value is displayed in
the result line c.
In this manner, you can measure any number of further lengths BX, which are
automatically added and multiplied with height A.
The condition for a correct area/surface calculation is that the first
measured length (in the example the room height A) is identical for all
partial surfaces.
Grade Measurement
After pressing the grade measurement button 3, the indication for grade
measurement appears on the display . The backside of the measuring tool is
used as the reference plane. By pressing the grade measurement button 3 again,
the side surfaces of the measuring tool are used as reference plane and the
display view is shown turned by 90°.
Press the measuring button 2 to lock the measuring value and accept it in the
measured values memory. Pressing the measuring button 2 again continues the
measurement.
When the indication flashes during the measuring procedure, then the measuring
tool was tilted too much in lateral direction.
If the “digital vial” function is activated in the basic settings, the grade
value is also displayed in the other measuring functions in line d of display
Timer Function
The timer function is helpful, when, for example, movements of the measuring
tool during measuring are to be prevented. To activate the timer function,
press and hold button 6 until the indicator appears in the display.
The time period from the actuation until the measurement takes place is
displayed in the measured-value line a. The time period can be adjusted
between 1 s and 60 s by pressing the plus button 11 or the minus button 5.
The measurement takes place automatically after the set
time period has elapsed. The timer function can also be used for distance
measurements within other measuring modes (e.g. area/surface measurement).
Adding and subtracting measuring results as well as continuous measurements
are not possible.
List of the last Measuring Values
The measuring tool stores the last 50 measuring values and their calculations,
and displays them in reverse order (last measured value first).
To recall the stored measurements, press button 7. The result of the last
measurement is indicated on the display, along with the indicator for the
measured-value list e and the memory location of the dis- played
measurements.
When no further measurements are stored after pressing but- ton 7 again,
the measuring tool switches back to the last measuring function. To exit the
measured-value list, press one of the measuring-mode buttons.
To continuously save the currently displayed length measurement value as a
constant, press and hold the measured-value list button 7 until CST is
indicated on the display. A measured-value list entry cannot be subsequently
saved as a constant.
To use a length measurement value in a measuring mode (e. g. area/surface
measurement), press the measured-value list button 7 , select the desired
entry and confirm by pressing the result button 6.
Deleting Measured Values
Briefly pressing button 4 deletes the last individual measuring value
determined in any measuring function. Briefly pressing the button repeatedly
deletes the individual
measuring values in reverse order.
To delete the currently displayed measured-value list entry, briefly press
button 4. To delete the complete measured-value list and the constant
CST , press and hold the measured- value list button 7 and at the same
time briefly press button 4. In wall surface measurement mode, briefly
pressing button 4 the first time deletes the last individually measured
value pressing the button a second time deletes all lengths B X, and
pressing the button a third time deletes the room height A.
Adding Measured Values
To add measured values, firstly carry out any measurement or select an entry
from the measured-value list. Then press the plus button 11. For
confirmation, + appears on the display. Then carry out a second
measurement or select another entry from the measured-value list.
To call up the sum of both measurements, press the result
button 6. The calculation is indicated in the measured-value lines a ,
and the sum in the result
line c.
After calculation of the sum, further measured values or measured-value list
entries can be added to this result when pressing the plus button 11 prior
to each measurement. Pressing the result button 6 ends the addition.
Notes on the addition
- Mixed length, area and volume values cannot be added to- For example, when a length and area value are added, ERROR briefly appears on the display after pressing the result button 6. Afterwards, the measuring tool switches back to the last active measuring mode.
- For each calculation, the result of one measurement is added (e.g. the volume value) for continuous measurements, this would be the displayed measured value in result line c. The addition of individual measured values from the measured-value lines a is not possible.
Subtracting Measured Values
To subtract measuring values, press minus button 5 For confirmation, is indicated on the display. The further procedure is analog to Adding Measured Values.
Data Transmission to other Devices
The measuring tool is equipped with a Bluetooth ® module, which enables data
transmission via radio technology to certain mobile terminals/devices with a
Bluetooth ® interface (e.g., smartphones, tablets).
For information on the necessary system requirements for a Bluetooth ®
connection, please refer to the Bosch website at www.bosch-pt.de.
For data transmission via Bluetooth ®, time delays between mobile
terminal/device and measuring tool may occur. This can be possible due to the
distance between both devices or the object being measured.
Data transmission to certain other devices with USB interface is possible via
the measuring tool s micro USB port (e.g. to computers, notebooks). In USB
operation, the charging duration n can be significantly prolonged during
data transmission.
- Activating the Bluetooth ® Interface for Data Transmission to a Mobile Terminal/Device
To activate the Bluetooth ® interface, press the measuring tool s
Bluetooth ® button 13. Make sure that the Bluetooth ® interface on
your mobile terminal/device is activated.
Special Bosch applications (apps) are available to extend the functional range
of the mobile terminal/device and for simplification of the data processing.
Depending on terminal/device, these can be downloaded at the respective app
stores
After starting the Bosch application, the connection between the mobile terminal/device and the measuring tool is established. When several active measuring tools are found, select the appropriate measuring tool. When only one active measuring tool is found, the connection is automatically established.
Note: When establishing the connection between the measuring tool and the
mobile terminal/device (e.g., smartphone, tablet) the first time (pairing),
the measuring tool s PIN code may be requested. In this case, enter 0000. The
connection status and the active connection are indicated on the display 1
( l ).
When a connection cannot be established within 5 minutes after pressing the
Bluetooth ® button 13 , the Bluetooth ® feature automatically switches
off to save the batteries/rechargeable batteries.
When operating the measuring tool in the measuring rail 27 , data
transmission is not possible.
Deactivating the Bluetooth ® Interface
To activate the Bluetooth ® interface, press the Bluetooth ® button 13
or switch the measuring tool off.
When the Bluetooth ® interface is deactivated or when the Bluetooth ®
connection is interrupted (e.g., because of too large distance or obstructions
between the measuring tool and the mobile terminal/device as well as
electromagnetic disturbances), Bluetooth ® ( l ) is no longer indicated
on the display.
Data Transmission via USB Interface
Connect the measuring tool to your computer or notebook with the micro USB
cable. After starting the software on your computer or notebook, a connection
is established to the measuring tool.
To download the current software and for further information, please refer to
the Bosch website at www.bosch-pt.de.
Note: As soon as the measuring tool is connected to a computer or
notebook via the micro USB cable, the lithium ion battery is charged. The
charge duration varies depending on the charging current.
To recharge the measuring tool as quickly as possible, use the provided
charger, see Battery Charging.
Working Advice
- The measuring tool is equipped with a radio interface. Local operating restrictions, e.g. in airplanes or hospitals, are to be observed.
General Information
The reception lens 17 and the laser beam outlet 18 must not be covered
when taking a measurement.
The measuring tool must not be moved while taking a measurement (with the
exception of the continuous measurement and grade measurement functions).
Therefore, place the measuring tool, as far as this is possible, against or on
a firm stop or supporting surface.
Influence Effects on the Measuring Range
The measuring range depends upon the light conditions and the reflection properties of the target surface. For improved visibility of the laser beam when working outdoors and when the sunlight is intense, use the laser viewing glasses 30 (accessory) and the laser target plate 31 (accessory), or shade off the target surface.
Influence Effects on the Measuring Result
Due to physical effects, faulty measurements cannot be excluded when measuring on different surfaces. Included here are
- Transparent surfaces (e.g. , glass, water),
- Reflecting surfaces (e.g., polished metal, glass),
- Porous surfaces (e.g. insulation materials),
- Structured surfaces (e.g. , roughcast, natural stone).
If required, use the laser target plate 31 (accessory) on these surfaces.
Furthermore, faulty measurements are also possible when sighting inclined
target surfaces.
Also, air layers with varying temperatures or indirectly received reflections
can affect the measured value.
Accuracy Check and Calibration of the Grade Measurement
Regularly check the accuracy of the grade measurement. This is done by
carrying out a reversal measurement. For this, place the measuring tool on a
table and measure the grade. Turn the measuring tool by 180 ° and measure the
grade again. The difference of the indicated reading may not exceed by more
than 0.3 ° (max.).
In case of greater deviation, the measuring tool must be recalibrated. For
this, press and hold the grade measurement but- ton 3. Follow the
directions on the display.
After severe temperature changes and impact, we recommend an accuracy check
and, if required, to recalibrate the measuring tool. After a temperature
change, the measuring tool must acclimate for a while before calibrating.
Accuracy Check of the Distance Measurement
The accuracy of the distance measurement can be checked as follows:
- Select a permanently unchangeable measuring section with a length of approx. 1 to 10 meters; its length must be precisely known (e.g. the width of a room or a door opening). The measuring distance must be indoors; the target surface for the measurement must be smooth and reflect well.
- Measure the distance 10 times after another.
The deviation of the individual measurements from the mean value must not exceed ±2 mm (max.). Log the measurements, so that you can compare their accuracy at a later point of time.
Working with the Tripod (Accessory)
The use of a tripod is particularly necessary for larger distances. Position the measuring tool with the 1/4″ thread 19 onto the quick-change plate of the tripod 29 or a commercially available camera tripod. Tighten the measuring tool with the locking screw of the quick-change plate. Set the corresponding reference level for measurement with a tripod by pushing button 10 (the reference level is the thread).
Working with the Measuring Rail
The measuring rail 27 can be used for a more accurate grade measurement
result. Distance measurements are not possible with the measuring rail.
Place the measuring tool into the measuring rail 27 as shown and lock the
measuring tool with locking lever 28. Press the measuring button 2 to activate
the “Measuring rail” operating mode.
Regularly check the accuracy of the grade measurement by carrying out a
reversal measurement or with the spirit levels of the measuring rail.
In case of greater deviation, the measuring tool must be recalibrated. For
this, press and hold the grade measurement but-ton 3. Follow the directions on
the display.
When operating the measuring tool in the measuring rail 27, data transmission
is not possible.
To end the “Measuring rail” operating mode, switch the measuring tool off and
remove it from the measuring rail.
Troubleshooting – Causes and Corrective Measures
The measuring tool monitors the correct function for each measurement. When a defect is determined, only the symbol shown aside flashes in the display. In this case, or when the above mentioned corrective measures cannot correct an error, have the measuring tool checked by an after-sales service agent for Bosch power tools.
Maintenance and Service
Maintenance and Cleaning
Store and transport the measuring tool only in the supplied protective pouch.
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any cleaning agents
or solvents.
Maintain the reception lens 17 in particular, with the same care as required
for eye glasses or the lens of a camera.
In case of repairs, send in the measuring tool packed in its protective pouch
26.
After-sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and
repair of your product as well as spare parts. Exploded views and information
on spare parts can al-so be found under: www.bosch-pt.com
Bosch’s application service team will gladly answer questions concerning our
products and their accessories.
In all correspondence and spare parts orders, please always include the
10-digit article number given on the type plate of the measuring tool.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: (0844) 7360109
Fax: (0844) 7360146
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch.com.au
Supplier code ERAC000385
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
Tel.: (011) 4939375
Fax: (011) 4930126
E-Mail: bsctools@icon.co.za
KZN – BSC Service Centre
Unit E, Almer Centre
143 Crompton Street
Pinetown
Tel.: (031) 7012120
Fax: (031) 7012446
E-Mail: bsc.dur@za.bosch.com
Western Cape – BSC Service Centre
Democracy Way, Prosperity Park
Milnerton
Tel.: (021) 5512577
Fax: (021) 5513223
E-Mail: bsc@zsd.co.za
Bosch Headquarters
Midlands, Gauteng
Tel.: (011) 6519600
Fax: (011) 6519880
E-Mail: rbsa-hq.pts@za.bosch.com
Disposal
Measuring tools, accessories and packaging should be sorted for environmental-
friendly recycling.
Do not dispose of measuring tools into household waste!
Only for EC countries:
According to the European Guideline 2012/19/EU, measuring tools that are no
longer usable, and according to the Europe-an Guideline 2006/66/EC, defective
or used battery packs/batteries, must be collected separately and disposed of
in an environmentally correct manner. Battery packs/batteries no longer
suitable for use can be directly returned at:
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: (0844) 7360109
Fax: (0844) 7360146
E-Mail: boschservicecentre@bosch.com
Battery packs/batteries:
- Integrated batteries may only be removed for disposal. Opening the housing shell can damage or destroy the measuring tool.
Completely discharge the battery. Unscrew all screws from the housing and open
the housing shell. Disconnect the battery connections and remove the battery.
Do not dispose of battery packs/batteries into household waste, fire or water.
Battery packs/batteries should, if possible, be discharged, collected,
recycled or disposed of in an environ-mental-friendly manner.
References
- Invented for life | Bosch Global
- Location selection | Bosch Power Tools
- Bosch Elektrowerkzeuge und Zubehör | Bosch Elektrowerkzeuge
- Home | Bosch in Australia
Read User Manual Online (PDF format)