innovators in instrumentation technology Non-Nuclear Asphalt Density
Gauge
Quick Start Guide
919-875-8371-Nonuke-Non-Nuclear-Asphalt-Density-Gauge.png" alt="InstroTek 919
875 8371 Nonuke Non Nuclear Asphalt Density Gauge" width="587" height="439" />
919.875.8371
Research Triangle Park, North Carolina
www.instrotek.com
Keypad Overview:
919-875-8371-Nonuke-Non-Nuclear-Asphalt-Density-Gauge-fig1.png" alt="InstroTek
919 875 8371 Nonuke Non Nuclear Asphalt Density Gauge - fig1" width="970"
height="323" />
NOTE: Press and hold Zero (0) Key for the decimal character
This guide covers the initial setup and basic operation of your gauge from
powering on to taking a measurement. Please refer to the Operators Manual for
more details. The following initial steps are recommended to start taking
measurements with the NoNuke. The gauge operation accuracy can be checked at
any time by using the Verification function in the menu item. Refer to the
manual to periodically verify the operation of the gauge.
- Powering the gauge ON
- Set Time/Date
- Set Units
- Input Max Density
- Input Mix Information: mat thickness and max aggregate size
- Take a Measurement
- Density Measurement
919-875-8371-Nonuke-Non-Nuclear-Asphalt-Density-Gauge-fig2.png" alt="InstroTek
919 875 8371 Nonuke Non Nuclear Asphalt Density Gauge - fig2" width="939"
height="368" />
Powering the Gauge ON
Press the ON key to power the gauge on.
When the gauge is powered on the NoNuke will show:| InstroTek
---|---
After 3 seconds the serial # and battery voltage will be displayed.| NoNuke
Rev #.##
Serial #:#
Battery: # V
After displaying this screen for 2 seconds, the gauge will be ready to be used
for testing.| Gauge Ready
to Begin
Date Time
Setting Time/Date
To provide the proper time and date for measurements, complete the following
steps. Press