The Mist AP45 contains four IEEE 802.11ax radios that deliver 4×4 MIMO with four spatial streams when operating in multi-user (MU) or single-user (SU) mode. The AP45 is capable of operating simultaneously in the 6GHz band, 5GHz band, and 2.4GHz band along with a dedicated tri-band scan radio.
I/O ports
Reset | Reset to the factory default settings |
---|---|
Eth0+PoE-in | 100/1000/2500/5000BASE-T RJ45 interface that supports |
802.3at/802.3bt PoE PD
Eth1+PSE-out| 10/100/1000BASE-T RJ45 interface + 802.3af PSE (if PoE- in is
802.3bt)
USB| USB2.0 support interface
AP45E Antenna attachment
-
Step 1
Unscrew the antenna port covers using a T8 security torx bit. -
Step 2
Connect antenna to the AP -
Step 3
Bend the breakoff tab on the covers. -
Step 4
Attach the antenna port cover on the AP using a T8 security torx bit -
Step 5
Put a few drops of the provided on the 6-pin port cover screws -
Step 6
Place the provided lexan labels on the port cover screws with the glue
AP45 Mounting
APBR-U Mounting box options
Holes : Mounting options
- US Single gang, 4 inch round, 3.5 inch round
- US Double gang, Wall/ceiling mount
- US 4 inch square
- EU junction box
In a wall mount installation, please use screws that have a 1/4in. (6.3mm) diameter head with a length at least 2 in. (50.8mm). APBR-U that is in the AP45(E) box includes a set screw and an eyehook.
Mounting to a 9/16 inch or 15/16 inch T-bar
-
Step 1.
Mount APBR-U to the t-bar -
Step2.
Rotate APBR-U to lock to the t-bar -
Step3.
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US single gang, 3.5 or 4 inch round junction box
-
Step 1
Mount APBR-U to the box using two screws and the #1 holes. Make sure Ethernet cable extends the bracket. -
Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US double gang junction box
-
Step 1
Mount APBR-U to the box using two screws and the #2 holes. Make sure Ethernet cable extends thru the bracket. -
Step 2
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
US 4 inch square junction box
-
Step 1
Mount APBR-U to the box using two screws and the #3 holes. Make sure Ethernet cable extends thru the bracket. -
Step 2
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
EU junction box
-
Step 1
Mount APBR-U to the box using two screws and the #4 holes. Make sure Ethernet cable extends the bracket. -
Step 2 Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 15/16 inch T-bar
-
Step 1
Mount the APBR-ADP-RT15 to the t -bar -
Step 2
Mount the APBR-U to the APBR-ADP-RT15. Rotate the APBR-U to lock to t he APBRADP- RT15 -
Step 3
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
Recessed 9/16 inch T-bar or channel rail
-
Step 1
Mount the APBR-ADP-CR9 to the t-bar -
Step 2
Mount the APBR-U to the APBR-ADP-CR9. Rotate the APBR-U to lock to the APBRADP- CR9 -
Step 3
Slide the AP with shoulder screws on the APBR-U until the lock is engaged
1.5 inch T-bar
- Step 1
Mount the APBR-ADP-WSlS to the t-bar
- Step 2
Mount the APBR-U to the APBR-ADP-WSlS. Rotate the APBR-U to lock to the APBR- ADP-WSlS
- Step 3
Slide the AP with shou lder screws on the APBR-U until the lock is engaged
Threaded rod adapter (1/2″, 5/8″, or M 16)
-
Step 1
Install the APBR-ADP-T12 to the APBR-U. Rotate to lock. -
Step 2
Secure the APBR-ADP-T12 to the APBR-U with the provided screw -
Step 3
Install the bracket assembly to the 1/2″ threaded rod and secure with the provided lock washer and nut. -
Step 4
Slide the AP with shoulder screws on the APBR-U until the lock is engaged The same instructions work for the APBR-ADP-TS8 or APBR-ADP-M16
The threaded rod adapter attaches to a rod that is either 1/2″-13, 5/8”-11, or M16-2.
Technical Specifications
Feature | Description |
---|---|
Power options | 802.3at/802.3bt PoE |
Dimensions | 230mm x 230mm x 50mm (9.06in x 9.06in x 1.97in) |
Weight | AP45: 1.34 kg (2.95 lbs) AP45E: 1.30 kg (2.86 lbs) |
Operating temperature | AP45: 0° to 40° C AP45E: -10° to 50° C |
Operating humidity | 10% to 90% maximum relative humidity, non-condensing |
Operating altitude | 3,048m (10,000 ft) |
Electromagnetic emissions | FCC Part 15 Class B |
I/O
| 1 – 100/1000/2500/5000BASE-T auto-sensing RJ-45 with PoE 1 – 10/100/1000BASE-T auto-sensing RJ-45 USB2.0
RF
| 2.4GHz or 5GHz – 4×4:4SS 802.11ax MU-MIMO & SU-MIMO
5GHz – 4×4:4SS 802.11ax MU-MIMO & SU-MIMO
6GHz – 4×4: 4SS 802.11ax MU-MIMO & SU-MIMO
2.4GHz / 5GHz /6GHz scanning radio 2.4GHz BLE with Dynamic Antenna Array
Maximum PHY rate
| Total maximum PHY rate – 9600 Mbps
6GHz – 4800 Mbps
5GHz – 2400 Mbps
2.4GHz or 5GHz – 1148 Mbps or 2400Mbps
Indicators| Multi-color status LED
Safety standards| UL 62368-1 CAN/CSA-C22.2 No. 62368-1-14 UL 2043
ICES-003:2020 Issue 7, Class B (Canada)
Suitable for use in environmental air space in accordance with Section 300-22(C) of the National Electrical Code, and Sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Warranty Information
The AP45 family of Access Points comes with a limited lifetime warranty.
Ordering Information
Access Points
AP45-US | 802.11ax 6E 4+4+4 – Internal Antenna for the US Regulatory domain |
---|---|
AP45E-US | 802.11ax 6E 4+4+4 – External Antenna for the US Regulatory domain |
AP45-WW | 802.11ax 6E 4+4+4 – Internal Antenna for the WW Regulatory domain |
AP45E-WW | 802.11ax 6E 4+4+4 – External Antenna for the WW Regulatory domain |
Mounting brackets
APBR-U| Universal AP Bracket for T-Rail and Drywall mounting for Indoor Access
Points
---|---
APBR-ADP-T58| Adapter for 5/8-inch threaded rod bracket
APBR-ADP-M16| Adapter for 16mm threaded rod bracket
APBR-ADP-T12| Adapter for 1/2-inch threaded rod bracket
APBR-ADP-CR9| Adapter for channel rail and recessed 9/16” t-rail
APBR-ADP-RT15| Adapter for recessed 15/16″ t-rail
APBR-ADP-WS15| Adapter for recessed 1.5″ t-rail
Power Supply options
802.3at or 802.3bt PoE power
Regulatory Compliance Information:
This product and all interconnected equipment must be installed indoors within the same building, including the associated LAN connections as defined by the 802.3at Standard. Operations in the 5.15GHz – 5.35GHz band are restricted to indoor usage only. If you need further assistance with purchasing the power source, please contact Juniper Networks, Inc.
FCC Requirement for Operation in the United States of America:
FCC Part 15.247, 15.407, 15.107, and 15.109
FCC Guideline for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance between the radiator & your body; AP45 – 50cm and AP45E –
59cm.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
- Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
- This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz / 5.925 ~ 7.125GHz frequency range, it is restricted to indoor environment.
- The 5.925 ~ 7.125GHz operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>