Ix nav LXNAV RS485-CAN Remote Control Stick Instruction Manual
- June 5, 2024
- Ix nav
Table of Contents
LXNAV RS485-CAN Remote Control Stick
Instruction Manual
Important Notices
The LXNAV CAN Remote is designed for VFR use only. All information is
presented for reference only. It is ultimately the pilot’s responsibility to
ensure the aircraft is being flown in accordance with the manufacturer’s
aircraft flight manual. The LXNAV CAN Remote must be installed in accordance
with applicable airworthiness standards according to the country of
registration of the aircraft.
Information in this document is subject to change without notice. LXNAV
reserves the right to change or improve its products and to make changes in
the content of this material without the obligation to notify any person or
organization of such changes or improvements.
| A Yellow triangle is shown for parts of the manual that should be read
carefully and are important for operating the system.
---|---
| Notes with a red triangle describe procedures that are critical and may
result in loss of data or any other critical situation.
| A bulb icon is shown when a useful hint is provided to the reader.
Limited Warranty
This LXNAV CAN Remote product is warranted to be free from defects in
materials or workmanship for two years from the date of purchase. Within this
period, LXNAV will, at its sole option, repair or replace any components that
fail in normal use. Such repairs or replacements will be made at no charge to
the customer for parts and labor, the customer shall be responsible for any
transportation cost. This warranty does not cover failures due to abuse,
misuse, accident, or unauthorized alterations or repairs.
THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY, INCLUDING ANY LIABILITY
ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE, STATUTORY OR OTHERWISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, WHICH MAY VARY FROM STATE TO STATE.
IN NO EVENT SHALL LXNAV BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, OR
CONSEQUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE, OR INABILITY
TO USE THIS PRODUCT OR FROM DEFECTS IN THE PRODUCT. Some states do not allow
the exclusion of incidental or consequential damages, so the above limitations
may not apply to you. LXNAV retains the exclusive right to repair or replace
the unit or software, or to offer a full refund of the purchase price, at its
sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY
BREACH OF WARRANTY.
To obtain warranty service, contact your local LXNAV dealer or contact LXNAV
directly.
Packing list
When ordering, the user should specify how the Remote will be used. With two different communication protocols available, we have to supply suitable adapters.
RS485 (LX90x0, LX80x0)
- LXNAV Remote stick
- RS485 splitter
- Hex key
CAN (S8x, S10x)
- LXNAV Remote stick
- CAN-485 Remote adapter
- CAN splitter S8x cable
- Hex key
Technical Data
- Power input 8-18V DC
- Consumption at 12 V: 60mA
- Weight 300g
Versions
Functionality
Diameter of command handles
Diameter | Gliders |
---|---|
19,3mm | DG, LAK, Shempp-Hirth |
20,3mm | LS, Stemme, Apis, EB29 |
24,0mm | Schleicher, Pipistrel Taurus, Alisport Silent, EB28 |
25,4mm | 35 |
Shapes
Installation
Remote can be used with LX90x0/LX80x0 navigation units as well as with S8x and S10x standalone variometers. Both Remotes are the same, the only difference is an additional converter on S-type variometers. The standard version has four colored wires and one shielded cable for PTT although early versions of Remotes have additional cable for speed command. Depending on the selected options there might additional cables or wires.
Power and communication wiring
Four separated wires with unique colors (blue, white, yellow, and red) must be
inserted into the spring terminals of the RS485 splitter or CAN-485 Remote
adapter. Be careful, to connect the correct wire to the pin, which is marked
with the same color.
Figure 1: Spring terminals on RS485 splitter for LX90x0/LX80x0 navigation units
Figure 2: Spring terminals on RS485-CAN Remote adapter for S8x/S10x variometers
RS485 (LX90x0, LX80x0)
LXNAV remote stick is connected to the RS485 bus directly through spring
terminals on the RS485 splitter.
| If you are installing remote sticks into double seater gliders or aircraft,
be careful.
The stick for the rear seat is marked as DS. DS remote stick is programmed to
control repeater unit, which is installed on 2nd seat.
---|---
| For detailed description, correct settings, and remote functionality read
the user manual for LX90x0 and LX80x0 units.
CAN (S8x, S10x)
LXNAV remote stick is connected to CAN bus through 485-CAN Remote adapter.
Spring terminals are wired to remote and SUB D9 connector to S8x cable set via
enclosed CAN Splitter S8x cable.
| The remote stick will not operate until is registered on the device. The
remote stick can be registered under a setup-hardware-Remote stick.
Registration must be done on each unit (front and back seat).
---|---
| For detailed description, correct settings, and remote functionality read
the user manual of S8x and S10x various.
Push to talk – PTT
A coaxial cable labeled “PTT” is wired directly to the PTT button and is
independent of other remote’s functionality. It should be wired to VHF radio
as per their installation manual. Shield usually goes to the ground and
center wire to pin on radio connector.
Speed command – SC
We have been working very hard to simplify the remote stick so that we can
have the same functionality but use fewer cables. The new version of the LXNAV
remote stick comes without the standard SC cable but the functionality is
still available. With the new stick, there is no more need to solder these
wires to the Vario wiring loom. The SC function is programmable through
LX90x0/LX80x0/S8x/S10x. To make the SC function work with the new stick,
please check the SC setting on the configuration/setup page. Go to **Setup-
Hardware->Digital inputs.
Please make sure that NONE of the inputs is set to “SC on/off switch” or “SC toggle button”.
However, there is still an option for the customer to have the previous version of the remote stick, where the “SC” cable should be wired to a V5 or S8x** cable set, depending on the instrument used.
Wiring of function switches
Trim switch
Remote can be ordered with 3 position momentary switch for trimming purposes.
Such remote has four additional wires with the label “IN: WHITE, OUT: RED”
where two white wires should be wired to positive and negative potential in a
glider, and the second pair of red wires go to the trim driver. Polarity is
not important, if the trimmer has the wrong moving direction simply switch one
pair of wires between them and the direction will be reversed.
Starter button
This option is for gliders with the electric starters on internal engines.
The remote has a red momentary button for starting engines on the ground or in
the air. The button is in a normally open configuration and makes contact when
it is pressed. Coaxial cable is separated from other wires and labeled as
“Starter” and should be wired to engine control unit as stated in their
manual.
Functions
RS485 (LX90x0, LX80x0)
The function button (Fn) has customizable functionality, which can be set by the user in the Setup– >Hardware–>Remote menu.
CAN (S8x, S10x)
Dimensions
Dimensions
Slanted insert
Mounting screws (DIN 916/ISO 4029 M 3 x 6)
Revision history
Rev | Date | Comment |
---|---|---|
1 | April-18 | Added chapters 1, 3, 6 and 7 |
2 | May-20 | Added chapte7 |
3 | January-21 | Style update |
4 | February-21 | Updated chapter 7 |
5 | May-21 | Added chapters 5.2 and 5.4.2 Updated chapter 7 |
6 | May-21 | Combined manuals for RS485 and CAN versions of Remote |
LXNAV d.o.o.
Kidrioeva 24, SI-3000 Celje, Slovenia
T: +386 592 334 00 I F:+386 599 335 22 I
info@Ixnay.com
www.lxnay.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>