Airvital CO2 Monitor Instruction Manual
- June 5, 2024
- Airvital
Table of Contents
CO2 Monitor Instruction Manual Customer service: contact@airvital.eu
Product Description
This product is an air quality monitor to measure carbon dioxide (CO2), temperature, and air humidity.
Precautions
- Do not cover the vents on the side and back of the product. It will result in inaccurate measurements.
- Do not use cleaning detergents on the monitor.
- Do not use water or other liquids near the monitor.
- Do not open or modify the monitor.
- Switch screen button
- Display
- On-off switch
- Temperature and humidity sensor
- Air vent
- USB charging port
Data visualization
On the main display, you can see the temperature, humidity, and carbon dioxide.
- Temperature indication in Celsius
- Relative humidity in %
- Carbon dioxide (CO2) in PPM
Trend visualization
When you press the switch screen button, you can see the trend display where you can see the CO2 values for the past 8 hours.
Color Indication for CO2 levels
The CO2 values on the display will change in color depending on the carbon
dioxide concentrations.
CO2 Air Quality
Air Quality| CO2 PPM| Color
Good| 0-999| Green
Moderate| 1000-1499| Yellow
Bad| 1500-2499| Red
Severe| >2500| Purple
Charging
During charging, the temperature sensor can be influenced. We recommend
leaving the device plugged in for more accurate temperature measurements. Use
the included charger to charge the device. The standby time is 6 hours.
Charging takes 2 hours.
Calibration
Rough handling, transportation, and aging can have an impact on the sensor’s
accuracy.
The sensor is equipped with a self-calibrating algorithm called ‘automatic
baseline correction’. This algorithm will auto-calibrate to the lowest CO2
readings it sees in a time span of several weeks. By placing the monitor
outside, the sensor will sense this and recalibrate over time.
The device has been calibrated in the factory but because of transportation
and different air pressure, we recommend placing the product outside for 10
minutes after you have received it. This will auto-calibrate the sensor.
Normal outdoor CO2 readings are around 410PPM.
Specifications
CO2 sensor
- Measuring range: 0-9999 PPM
- Sensor for CO2: Infrared (NDIR)
- Resolution: 1 PPM
- Accuracy: ±50ppm ±5%
- Response time: 30 seconds
- Allow two minutes for accurate CO2 measurements after startup.
- Life expectancy: 15+ years
Temperature and humidity sensor
- Temperature range: -40 to 90 ° C
- Measuring accuracy: ±2 ° C
- Humidity range: 0% to 100% RH
- Measurement accuracy: ±5% RH
- Allow two minutes for accurate measurements after startup.
Find us online :
• https://airvital.eu
Is something wrong or is the product not what you thought it was? Contact
customer service :
• contact@airvital.eu
Chat with us on Facebook :
• https://airvital.eu/facebook
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>