Product Introduction

Mobisun series portable power station is built by our company after many years of professional accumulation based on extensive user’s feedback. The new design adopts imported lithium batteries as the energy storage main body. It has the features of small size, large capacity, lightweight, high power, easy to carry and so on, providing you the simple solution of mobile power supply. It is widely used in outdoor offices, medical rescue, fire protection Rescue, field recreation, emergency communications, and environmental monitoring.

  • Intelligent Fully-Automatic Dynamic Charge and Discharge Management Platform
  • Multi-function display, showing battery voltage and battery power, voltage output and power output
  • Small size, large capacity, lightweight, easy to carry
  • SPWM pulse width modulations in a wave, high precision low ripple voltage output
  • Sine wave AC 220V voltage output Can supply power to most electrical equipment
  • Built-in high capacity, long life, high-efficiency lithium-ion battery
  • Can output AC (220V) and DC (DC5V) at the same time
  • With Overcharge and over-discharge protection, power monitoring, and low battery warning function.
  • With short circuits, overload, temperature and other protection functions, it is safe and reliable. There is a security warning and sign and cautions.

Button Instructions

MPSG1800 Button Instruction

  1. Battery Voltage
  2. Output Voltage
  3. AC Output
  4. Lighting Switch
  5. LED Light
  6. DC 5V Output
  7. DC 12V Output
  8. Charging Input
  9. Power Switch

Operation Instruction

Operation Step

  1.  Make sure the power of AC electrical appliance connected with a portable power station is lower than the rated output of the power station. If it is higher, please use the higher output portable power station.
  2. Plug the plug of the appliance into the AC main power socket firstly, and then turn on the power switch and the power station will work well.
  3. Multi-function LCD Screen can indicate battery voltage, battery level, AC output voltage and load output.
  4. When the battery voltage is low, the output will stop, the screen will be turned off and the buzzer will alarm, meaning this power station need to be charged.
  5. Please turn off the power switch after use the power station. Please charge the power station if the battery voltage indicates low.

Caution:
When the voltage of the battery is lower than 45V, the load should be reduced to less than 1/3 of the rated load to prevent the battery from being discharged too quickly and to protect the power station.

Operation Caution

Strictly comply with operation steps when using power stations. It should be operated under cool and dry circumstances and do not let water or other fluid substance immerse in the power station. To keep perfect heat dissipation, ensure that at least 5CM space around the power supply airflow is unobstructed. It is prohibited that use power stations under inflammable, explosive, corrosive gases environments such as gasoline and gas.
Power Charge: The power station is equipped with a battery charger, which is automatically a battery charge adapter without human intervention. It is suggested to charge the battery without any load. If long time no use, please make sure the power station will be charged once every 3 months.

Operate AC Load

The power provided by a multi-functional portable AC&DC power station is rated load power, which is applicable for those AC appliance power that are lower than this rated load power.But for some electrical appliances, the starting power is higher than the rated power when startup. For example, inductive load equipment starting power is generally 6-8 times higher than its rated power. Such as energy-saving lamp starting power is dozens of times the power of its rated power. The overload protection will be activated and the output will be automatically disconnected once the electrical appliance starting power is higher than the peak power of the power station.

Technical Parameters

Model No MPSG1800
Battery Type Lithium Battery
AC Current Output 10A
AC Voltage Output 220V
Power Output 1800W
Peak Power 3600W
Waveform Output Sine Wave
Frequency 50HZ
DC Voltage Output –  Cigarette lighter DC 12V/10A

–  Waterproof battery terminals 48V/30A, PEAK 60A

– 2 x USB 3.6-6.5V/3A, 6.5V-9V/2A, 9V-12V/1.5A

Protection functions| Over Charge, Over Discharge, Overload, Over Temperature, Short Circuit,

Under Voltage etc.

Charging parameters| 54.6V/10A
Battery capacity| 48V/60Ah
Charging time| 6h
Cycle life| >3000 times
Appearance size| 458348205(mm)
Weight| 25.0Kg

Working Temperature

  • Working Temperature:-20℃–65℃
  • Working Humidity:0%RH–90%RH

Load Reference Time

Equipment Power(W) Usage Time(h)

MPSG1800
LED Light| 5| 600
LCD TV| 30| 100
Laptop| 45| 60
Household fans| 75| 40
Audio| 150| 20
Refrigerator| 150| 20
Desktop computer| 200| 15
Washing machine| 300| 9
Vacuum cleaner| 500| 6
Air Conditioning (1P)| 800| 3
Microwave oven| 1200| 2.5
Electric kettle| 1500| 2
Electric heating| 2000| /
Electric water heater| 2200| /

Note: The above load test use time is for reference only. The actual use time will vary depending on the brand of the load product.

Application Area

Mobisun-MPSG1800-Portable-Power-Generator-
fig-2

Application Area

The multi-functional portable AC&DC power station can be applied for Medicaid, emergency communication, environment monitoring, firefighting, army field practice, outdoor work, household power outage as well as remote rural without electricity, advertising media for outdoor shooting, Except for above this normal application, it also can be used in tasks and administration, such as installation and maintenance of telecom network optimization, the army information technology company, the geographical survey task force, miners oil exploration team, architectural survey, water detection, investigation on wild resources of forestry agriculture etc .

Troubleshooting

  1. No AC Output: Check LED displays or not. If not, please charge the battery for 1 – 2mins to activate battery output.
  2. No DC Output: Turn on the POWER switch.
  3. Long time alarm: Overheat or low battery level will lead to long time alarm. If the temperature is too high, please stop using the power station and let it cool down before using.If battery voltage is too low, please recharge the power station timely.
  4. Lamp not light: Turn on the power switch again and then switch on the light.
  5. No display on the screen, when powered on: The battery voltage, is low and is under protection. Please turn off the “POWER” button, then plug in the charger. Please use the battery when it is fully charged.

Mobisun B.V.
Adress: Markenhaven
City: Amersfoort
Zipcode: 3826 AC
Country: Netherlands
Phonenumber: +31 85 3033 500
Email: info@mobisun.com