MASTER DH 752 P Professional Dehumidifier
PLEASE TAKE TIME TO READ THIS MANUAL CAREFULLY BEFORE USE AND SAVE IT FOR FUTURE REFERENCE.
BEFORE USE
These symbols on your device mean:
- This appliance is filled with Propane gas R290. Follow strictly the manufacturer’s instruction concerning use and repairs!
- Before using the machine, read carefully the entire instruction manual.
- Do not install, operate or store the device in a room smaller than 4m2.
GENERAL CAUTIONS
-
FOR INDOOR USE ONLY.
-
Do not use in cabinet, closet, boats, caravans or similar locations.
-
Do not use the unit in swimming pools, washrooms or similar wet areas.
-
Leave the unit to stand for 12hours before connecting to the mains supply after transport or when it has been titled (ex. During cleaning).
-
Only use the unit in the upright position on a flat level surface (even during transport!) and at least 50cm from any objects.
-
Do not use the unit in a potentially explosive environment containing combustible liquids, gases or dusts.
-
Do not use the appliance in the vicinity of flammable or explosive substances or fuels. Never use any paint, cleaning sprays, anti-insect sprays or similar near the unit; this could deform the plastic or cause electrical damage.
-
Ensure that there is at least 50cm between the sides of the appliance and any flammable, heating materials.
-
Do not place objects on the unit or restrict air inlet/ outlet.
-
Avoid the unit from splash.
-
Closely supervise any children and pets when the unit is in use.
-
CHILDREN SHALL NOT PLAY WITH APPLIANCE.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Switch off and unplug the unit when not in us
-
Never leave a functioning device unsupervised.
-
Do not pull the unit along by the cord.
-
Avoid over-twisting, -coiling, -pulling the power cord, never use nylon or iron wire to tide the power cord.
-
Make sure that the plug and socket remain visible and= accessible at all the time.
-
Do not use extension cords.
-
Never reach to retrieve the unit if it has fallen in water. In such case, immediately pull the plug. Have the unit checked before using it again.
-
The appliance shall be installed in accordance with national wiring regulations.
-
Do not exceed the recommended room size for max. efficiency.
-
Close the doors and windows.
-
Keep curtains or blinds closed during the sunniest hours of the day.
-
Keep filters clean.
Do not turn on the appliance if you have discovered damage to the appliance, cord or plug, if the appliance is malfunctioning or if there are signs of any other defect. Return the complete product to the vendor or to a certified electrician for inspection and/or repair. Always ask for original parts. The appliance (incl. cord and plug) may only be opened and/or repaired by properly authorized and qualified persons. -
ONLY A LICENSED PROFESSIONAL IS ALLOWED TO DISMANTLE OR MODIFY THE APPLIANCE.
-
THE MACHINE IS TO BE USED ONLY FOR ITS PRESCRIBED PURPOSE. ANY OTHER USE IS DEEMED TO BE A CASE OF MISUSE. THE USER/OPERATOR, NOT THE MANUFACTUER WILL BE LIABLE FOR ANY DAMAGE OR INJURIES OF ANY KIND CAUSED AS A RESULT OF THIS.
-
Always keep the unit in vertical position.
-
Keep all foreign objects away from the air intake or output openings.
-
The mains supply must conform to the specification shown on the rating plate at the back of the unit.
-
If the supply cord is damaged, it must be replaced by an approved service representative or a similar qualified person in order to avoid a hazard.
-
Never use the plug to start and stop the unit. Always use switch on the control panel.
-
Before moving the unit, first switch off, then unplug and empty the water tank.
-
Don’t use bug sprays or other flammable cleaners on the unit.
-
Never pour or spray water over the unit.
-
THIS APPLIANCE IS NOT INTENDED FOR USE BY
-
Please do not cut off the power by pulling the wire.
-
Please do not plug or unplug to startup or shut off the unit.
-
Please be careful when moving the unit, do not mangle the wire.
-
Please do not put fingers or sticks into the grid.
-
Please prohibit child to climb, stand or sit on the unit.
-
Please unplug the unit before cleaning or maintenance.
SAFETY RELATING TO REFRIGERANT R290
- Read these warnings carefully.
- This appliance contains the refrigerant R290. R290 is a refrigerant that complies with the relevant European Directives. Never perforate the refrigerant circuit. R290 is flammable (GWP3)!
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn any of the components of the cooling circuit of the unit. Do not set light to the unit.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Appliance should be installed, operated and stored in a room with a floor area larger than 4m2.
- Be aware that the refrigerants may not contain an odour, which means you cannot smell leaks.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
- Servicing shall only be performed on the grounds as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants
NOTICE: WE SUGGEST THAT ANY REPAIRS SHOULD BE EXECUTED BY PROFESSIONAL SERVICEMEN
- please make sure the unit is grounded
- please do not use unit in airproof conditions
- please follow the instructions thoroughly
PRODUCT INTRODUCTION
Dehumidifiers can reduce air humidity in room and thus make people live comfortably and goods stored properly. Due to their neat appearance, compact configuration, high quality and easy operation, our dehumidifiers are widely used in research institutions, industry, transportation, medical centers, measuring institutions, stores, underground constructions, computer rooms, archives, warehouses, bathrooms, etc. Keeping apparatus, meters, computers, communication equipments, drugs and files away from moisture, eroding, and mildew.
CONSTRUCTION
- Handle
- Control panel
- Wheel
- Water tank
- Water tank panel
- Filter grill
- Hour counter
Control panel
- humidity display
- operate indicator
- defrost indicator
- memory indicator
- tank full indicator
- memory
- humidity up
- humidity down
- on/off button
OPERATION INSTRUCTION OF KEYS
- ON/OFF: Press ON/OFF, the unit runs in a circulation “ON-OFF-ON”.
- Humidity up and down: Press “humidity up and down” for once, the set humidity will increase or decrease by 1%. Press the key for 1.5 seconds and the set value will increase or decrease by 1%. Press continuously with the speed 5 points per second.
- Memory Key: Press the memory key and the mem-ory indicator will light on to start the function of memory when the power cuts off. Press the memory key again; the memory indicator dies to shut off the function of memory when the power is cut off.
START ON
- Plug on the unit gives off “di”.
- Press “ON/OFF”, the running indicator lights on, and the humidity display window lights on to display the previ-ously set humidity. The initial humidity setting is 60% and 3 seconds later the humidity display window lights on to display current humidity.
- Press humidity up or down key to adjust the humidity needed. If the set humidity is 3% less than current hu-midity, the unit runs; if the set humidity is 3% more than current humidity, the unit stops running.
- When set humidity is less than 30%, the unit dehumidifies continuously, and the humidity display window reads “CO
SHUT OFF
Press “ON/OFF” when the unit is running, the unit stops running and all indicators die.
NOTICES:
- When the set humidity is higher than current humidity, the unit will not run.
- When the tank is full, the tank full indicator lights on, meanwhile, the compressor and the fan motor shut off automatically, and the buzzer gives off “DD” sound. Unless the tank is emptied, the buzzer gives the “DD” sound every 5 minutes. Only after emptying the tank the unit will start running again.
- When dehumidifying, the fan motor and compressor must be running at least for 3 minutes, once the compressor starts on. It is strongly forbidden to restart the compressor again within 3 minutes after the shut off.
- When operating in low temperature, the unit judges the system temperature automatically to defrost. When defrosting, the defrosting indicator lights on, the compressorruns but fan motor shuts off automatically.
- When you press the memory key, the controller will record current humidity even if the power is off. The unit will run under previous mode after power supplied again.
- The humidity display window shows humidity from 30% to 90%.
- Keep the unit unplugged if not used for a long time.
CONTINUOUS DRAINAGE:
Take out the tank, open drainage gate at the bottom of tank, connect pipeline,
fix the tank back, and pull the pipeline out from the bottom of the machine.
MAINTENANCE AND SAFETY
- FIG. 3 Do not use any relay, prolonged wire or adaptor. Otherwise, it might result in fire, radiation, or an electric shock.
- FIG. 4 Do not put the unit nearby stove or heater. Otherwise parts of unit might melt down or even catch fire.
- FIG. 5 Do not use the unit in the direct sunshine, wind or rain. (only for indoor usage)
- FIG. 6 In case of any other problems (for example smell of scorch ), please shut off the unit and unplug it. Otherwise, it might result in fire, electric shock or other malfunctions.
- FIG. 7 Do not use the unit in places easily affected by chemicals. Strong chemicals might damage the unit and cause the leakage.
- FIG. 8 Please unplug the unit when not used for a long time.
- FIG. 9 When cleaning, shut off and unplug the unit. Otherwise, it might result in an electric shock.
- FIG. 10 When draining continuously, put the drainer for smooth drainage. If the ambient temperature is as low as freezing, do not drain continuously.
- FIG. 11 Do not repair or disconnect the unit yourself. Otherwise it might result in fire or an electric shock.
- FIG. 12 Put the unit stably. If the unit turns over, the water will flow out from the tank and damage the objects nearby. Moreover, because of the damage, it might result in fire or an electric shock
- FIG. 13 Make the filter more endurable. When off for a long time, seal the filter in a plastic bag.
- FIG. 14 Do not use the unit near water. The unit might be damaged when soaked in water, so as to result in fire or electric shock.
- FIG. 15 Use the standard electric source of 220-240V/~50Hz. Otherwise it might result in fire or electric shock.
- FIG. 16 Do not damage the wire. Do not put anything heavy on the wire or heat or pull the wire. Otherwise it might result in fire of an electric shock.
- FIG. 17 Clean the dirt on the plug and fix it tightly. If the plug is not fixed tightly, it might cause an electric shock.
- FIG. 18 Do not regard the plug as a switch. Otherwise it might result in fire or an electric shock.
NOTICES ABOUT UNIT OPERATION
- When moving the unit, do not tilt over 45°to avoid any damaging of the compressor.
- The unit should be operated between 5°~32°.
- When dehumidifying, because of the heat resulted from the running compressor, the indoor temperature will rise by 1°~3°. Such a reaction should be considered as normal.
- When indoor temperature is below 10°, and the ambient absolute humidity is quite low, it is unnecessary to use the machine.
- Air inlet and air outlet should be at least 10cm away from the wall.
- Try to keep the room closed to enhance the dehumidification effect.
- Too much dirt on the filter affects dehumidification, may even result in malfunctioning of it, thus it should be cleaned at least once a month. If there is a great amount of powder in the air, the filter must be cleaned once a week, or even every day. Pull the front panel out and clean the filter. If necessary, you may slightly knock all over the filter, use a vacuum cleaner to remove bigger pieces of dirt or even wash the filter in warm clean water (≤40% with some neutral detergents) and then dry it.
TROUBLE-SHOOTING
UNIT DOES NOT WORK
Analysis
- Power cut
- Switch off
- Unplugged
- Fuse melted
- Tank full
Solution
- Power on
- Switch on
- Plug on
- Exchange fuse
- Empty the tank and replace it
DEHUMIDIFIES IN INADEQUATELY
Analysis
- Filter choked by dirt
- Some barrier in air inlet or outlet
- Door or windows open
- Refrigerant leakage
Solution
- Clean the filter
- Remove the barrier
- Close the door and windows and seclude from the sunshine
- Contact the manufacturer or seller
STRANGE NOISE
Analysis
- Until instable
- Filter choked
Solution
- Place the unit stably
- Clean the filter
- When above malfunctions occur and they could not be removed, please contact the supplier or seller, do not disassemble the machine yourself.
- When the unit starts or stops running, it makes certain noises of refrigerating circulation, which should not be considered as a malfunction.
- Hot air coming from the air outlet is normal.
INSTRUCTION ON MALFUNCTION CODES
The unit analyzes malfunction automatically and displays the code on the humidity window
- MALFUNCTION DISPLAY E1 Sensor of humidity
- MALFUNCTION DISPLAY E2 Sensor of refrigeration pipeline