FILTERQUEEN MAJESTIC High-Filtration Surface Cleaner User Manual

June 5, 2024
FILTERQUEEN

FILTER-QUEEN-LOGO

FILTERQUEEN MAJESTIC High-Filtration Surface Cleaner

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-Cleaner-
PRO

MAJESTIG* PARTS

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-1

  1.  On/Off Switch Contains ihe international symbols “T for ON and “0” for OFF.
  2.  Exhaust Cap Remove to comvert the Majestict to an efficient blower.
  3.  Caution Light Lights up when the motor has overheated. Motor automatically shuts off to prevent damage. Turn the Majestic off and unplug cord from wall. Let unit cool. This condition is usually caused by an obstructed air flow. Check for blockages in the hose, wand, or attachments. Filter may also need to be replaced. If the problem persists, take the Majestic to an Authorized Service Center
  4.  Scent Chamber Use one of Majestic’s Scents to freshen the air in your home while you clean.
  5.  Suction Inlet Use to comect hose to unit. Helps impart cyclonic action.
  6.  Clamp Keeps an air tight seal between the power unit and dirt container, yet opens quickly and easily.
  7.  Caster Set Rubber ball casters roll smoothly on rugs or hard surfaces. Always align one caster nder suction inlet to prevent tipping .
  8.  Power Nozzle Outlet Plug in for electric hose.
  9.  Attachment Crown Holds four of the most essential cleaning attachments within easy fingertip reach.FILTERQUEEN-MAJESTIC-High-Filtration-Surface-Cleaner-2
  10.  Upholstery Nozzle and Brush Remove embedded dirt from overstuffed furniture, mattresses, and drapes.
  11.  Crevice Tool Reach hard 1o reach places
  12.  Dusting Brush Eliminates the need for a dust cloth.
  13.  Bare Floor Brush Cleans hardwood, tile, linoleum, and other hard-surfaced floors.
  14.  Power Nozzle Attachment Kit Includes Power Nozzle * electric hose power wand.

AIR-SCENTING CHAMBER

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-3

Using the air-scenting chamber

  1.  Remove exhaust cap on top of Majestic” with a slight turn to the left and lift off.
  2.  Mist the grey felt air-scent pad with one or two sprays of your desired Genuine Health-Mor/FLTERQUEEN Fragrance. WARNING-TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY: Do not use perfume or alcohol-based liquids in the FILTERQUEEN Majestic. Use Genuine Health-Mor/FILTER QUEEN Fragrances sparingly-DO NOT SATURATE scent pad. Use of non-genuine Health-Mor/FILTERQUEEN* scents/fragrances in any manner other than described in the owner’s manual could cause damage to your motor, and will void your warranty.
  3.  Close air-scent chamber by replacing cap and locking with a slight turn to ight until it locks into place.
  4.  Start power unit and resume cleaning. Within minutes you will notice the effects of your Majestic” air-scenting chamber throughout the room.

ASSEMBLY AND OPERATION

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-4

For suction operation:

  1. A Connect hose to suction inlet on dirt container by lining up arrow on hose with metal pins on inlet and lock with a quarter tum to the right.
  2. A Connect wand or cleaning attachment to hose by inserting male end into hose and rotating it until the attachment or wand snaps into place.
  3.  Use accessories as recommended on the following pages.

For blowing operation:

  1. B Remove the exhaust cap with a quarter turn to the left.
  2. B Connect hose to inlet on top of unit by lining up arrow on hose with metal pins on inlet and lock with a quarter turn to the right.
  3. Connect wand or cleaning attachment to hose by inserting male end into hosce and rotating it until the attachment or wand snaps into place.
  4.  Use accessories as recommended on the following pages.

POWER NOZZLE

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-5

ATTACHING POWER NOZZLE:

  1. Assemble for suction cleaning.
  2.  Connect wand to nozzle by pushing the female end of the wand over the male end of the swivel neck of the nozzle until the locking button of the wand snaps into place. The wand swivels more than 90 degrees allowing it to lie flat on the floor.
  3.  Plug cord extending from other end of hose into the outlet on the power unit. PLEASE NOTE: The “ONIOFF” markings on the hose feature the international symbols of ” for ON and “O” for OFF. This switch only controls turning the power nozle on or off. To turn the power nozzle ON (for carpets) slide the switch to the most forward position. To turn the power nozle OFF (for wood, tile and linoleum floors) slide the switch to the rear position.
    NOTICE: This hose contains electrical wires.

CLEANING WITH THE POWER NOZZLE:
The Majestic” power nozzle requires no rug surface height adjustment. The shape of the power nozzle body has been specially designed to allow it to be effective on any rug or bare floor surface. Use long. slow strokes when cleaning. For thicker rugs, use a criss-cross pattern to raise nap and give them a fluffier appearance.

To clean stairs:

  • Remove caster set from power unit.
  • Set Majestic” on landing.
  • Remove wand and connect hose handle directly to power nozzle.

STORAGE: Avoid sharp bends in hose by removing hose from the unit before storing
CAUTION: Do not use on carpets or rugs with fringe or loose fibers.

PERIODIC MAINTENANCE:FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-6

There are no user-serviceable parts within the Majestic power nozzle. Should any issue arise that requires service, please contact your local FILTER QUEEN Distributor for service. Note that your power nozzle roller brush must be replaced periodically in order to maintain maximum cleaning performance. Contact your local FILTERQUEEN* Distributor for service.

Power nozle resettable circuit breaker:
The circuit breaker is designed to protect the motor of the power nozzle from damage, should it become clogged or the revolving brush stalls. To reset the circuit breaker, turn off the Majestic” and unplug cord from wall outlet. Remove any foreign objects from power nozzle and press the red button on the back of the nozzle. Plug Majestic in and resume use.

Power unit caution light:
When lit, the caution light indicates that the motor of the power unit has overheated. The motor automatically shuts off to prevent damage. Turn Majestic off and unplug cord from wall. Let unit cool. This condition is usually caused by an obstructed air flow. Check for blockages in the hose, wand, or attachments. Filters may also need to be replaced. If the problem persists take the Majestic” to an Authorized Service Center.

ATTACHMENTS

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-7

THE DUSTING BRUSH:
For easy dusting Assemble Majestic” for suction cleaning. Do all your general dusting with the round brush – it virtually eliminates your need for a dust cloth. Use on highly-polished furniture, the most delicate cloth lampshades, or any surface where dust accumulates.
For general room dusting: Atach brush directly to hose. Clean with gentle short strokes; do not press down hard as this will seal the opening and cut off your cleaning power
To clean brush: Run open end of hose over bristles of brush. If you have been dusting grimy or very sooty surfaces, remove bristle assembly from ubber socket, wash in wam soapy water: let dry before replacing.

CREVICE TOOL:
For hard to reach places Assemble Majestic” for suction cleaning. Use crevice tool for removing dust and dirnt behind cushions in upholstered furniture, mattress tufts and bindings, bed springs, corners of drawers, radiators, and any other place that’s hard to reach.
NOTE: When cleaning radiators, use crevice tool for suction first, but if coils are too close together to reach the dirn, hang damp cloth or newspaper behind rudiator, assemble Majestic for blowing and blow dust ou onto cloth or paper Assembled for blowing, Majestic unit and crevice tool may be used to defiost your efrigerator, aerate rugs, or inflate party balloons.

BARE FLOOR BRUSH:FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-8
For hard floors and walls Assemble Majestic” for suction cleaning. Ideal for hard-surfaced floors such as tile, linoleum, wood, and concrete floors. The bare floor brush cleans a wide area with one simple stroke. It is also effective in cleaning walls, screens, ceilings, shades, or any flat surface.
NOTE: When cleaning wall surfaces, always work in a straight line from the bottom up.
To clean hard surfaces: Attach brush to end of wand and use in same manner as the power nozzle.
To clean brush: After each use, remove lint, threads, ete.. by rubbing open end of hose over brush. If brush is soiled, rinse in mild soap solution and let dry before using on light-colored areas.

UPHOLSTERY NOzZLE AND BRUSH:
For upholstery and drapes Assemble Majestic” for suction cleaning.
To clean overstuffed furniture and mattresses: Use the nozzle without the brush to remove deeply embedded dirt; use the nozzle with brush when fabric is covered with threads, lint, ete.
To clean curtains and drapes: Attach wand to hose. For heavy drapes, attach nozle only directly to wand. For delicate curtains, use the nozzle and brush. Brush will prevent delicate materials from being drawn into the nozzle.

CHANGING THE FILTER CONES

FILTERQUEEN-MAJESTIC-High-Filtration-Surface-
Cleaner-9

For best performance, replace Cones as recommended by the manufacturer:

  • Cellupure Filter – every month
  • MEDIpure. every 6 months
  • Flat Disc Filter – every 6 months

CAUTION- DO NOT operate your power unit withou Filter Cones in place.
BEWARE OF IMITATIONS: Use only Gemuine lealth-MoriFILTERQUEEN Filter Cones. Imitations can resuit in poor performance and cause damage to your unit.

  1.  Unplug power cord from wall and detach hose from power unit.
  2.  Relcase side clamps and remove power unit from dirt container
  3.  Remove MEDIpure Cone and set aside or discard if installing new Cone
  4.  Empty contents of dirt container into a large, open garbage bag. Allow contents of the container to fall including used Cellupure Filter Cone. Dirt container may be washed and thoroughly dried to remove all dust and/or any odors.
  5.  Open a new Cellupure Filter Cone. Insert point of Cone into Filter Cone locator in the bottom of the dirt container. Be sure all edges of the Cone are even with the gaskct of the dirt container.
  6.  Place the MEDIPure Conc inside the Cellupure Filter.
  7.  Replace power unit and lock side clamps in place. Be sure all three tabs of the Ccllupure° Filter Cone are visible outside the power unit.3.

CHANGING THE FLAT DIsĆ FILTER

  1.  Unplug power cord from wall and detach hose power unit.
  2.  Release side clamps and remove power unit from dirt container.
  3.  Remove the Cone guard. Next, remove the Flat Disc Filter by pulling back the plastic retainer ring with your finger and lifting it out.
  4.  Replace Flat Disc Filter. Place the filter over the center section of the screen. Replace the retainer ring by squeezing ring. Make sure ring fits snugly under the three tabs of the plastic screen. Replace the Cone guard. Be sure the outer edge of the Cone is seated on the rubber lip around the circumference of the power unit and replace screw.

WARRANTY

Health-Mor warrants the Majestic Home Cleaning System canister unit and motor to be free of defects in material and workmanship for two years from the date of purchase. All accessories including the hose, attachments, and power nozzle, are warrantied for one year. This warranty does not cover:

  1. use of the Majestic for commercial, institutional, professional, rental, or other non-household purposes;
  2. ordinary wear items including brushes, belts, bearings, seals, and filers;
  3. damage occurring through misuse or negligence;
  4. damage caused by use on a current or voltage other than stamped on the nameplate;
  5. damage resulting from service work performed by other than Health-Mor or its authorized Distributors; and

cost of transportation, pick-up, delivery, house or service calls. Health-Mor will repair or replace any defective parts under this warranty provided the Majestic or the defective part is returned, transportation prepaid, with proof of purchase date, to the authorized Distributor from whomit was purchased or to Quality Assurance Department, Health-Mor, 13325 Darice Parkway, Unit A, Strongsville, Ohio 44149, U.S.A., or, with written authorization from Health- Mor, to any oxther person authorized to perform warranty service. Information regarding other persons authorized to perform warranty service canbe obtained by calling the Health Mor Customer Relations Department at, 440-846-7800. If the Majestic or part is found on inspection to be defective in material or workmanship it will be repaired or replaced at the option of Health Mor and returned to the sender, freight or postage collect. No reimbursement will be made for replacement of defective parts or service performed during the waranty period if done by anyone other than the authorized Distributor from whom the Majestic was purchased or by Health-Mor, without first having obtained written authorization from Heath-Mor. This waranty is uill and void and of no effect uness all of the following conditions are met:

  1.  the Majestic was purchased from an authorized Distributor or Health- Mor,
  2.  the manufacturer’s serial number for the Majestic has not been changed, defaced or removed;
  3.  The Majestic has been used at all times in accordance with the instruction manual and has not been sıbject to abuse;
  4.  only genuine FILTER QUEEN fiters and/or parts have been used with the Majestic.

LIFETIME SERVICE BENEFIT

Health Mor agrees to rebuild or replace the electrical system of the Majestics canister at any time after
expiration of the original warranty period, subject to the terms and conditions set forth below.

  1. The Majestic mast be in the possession of the original owner, mst have been used only for household purpose. This service policy does not apply to any Majestic” used for the commercial, institutional, professional, rental or other non-household uses.
  2. The Majestic must be returned, transportation prepaid, to the authorized Majestic Distributor from whom it was purchased, or to the Quality Assurance Department, Health-Mor, 13325 Darice Parkway, Unit A, Strongsville, Ohio 44149, U.S.A. The owner maust pay return transportation charges.
  3. The maximum charge for rebuilding the electrical system of the Majestic canister will be $99 US Dollars which will include the cost of all parts and labor necessary to restore the Majestic electrical syste m to correct operating order. A charge will be made at the then-current prices for any parts missing from the Majestic at the time it is delivered for rebuilding. if such parts are necessary to restore the Majestic to correct operating condition and for any parts needed or requested other than the electrical systems of the canister.
  4. If there is a defect in material or workmanship in the rebuilding, the Majestic will be rebuilt again atno charge, provided the Majestic is returned within two years of the prior rebuilding to Health-Mor or the authorized Distributor who performed the rebuilding, transportation prepaid. Proof of the prior rebuilding must accompany the Majestic”.
  5. This service agreement is void and inapplicable uness all of the following conditions are met:
    • a) The Majestic was purchased from an Authorized Distributor
    • b)The manufacturer’s serial umber for the Majestic has not been changed, defacod or removed;
    • c)Damage to the power plant did not occur by reason of misuse, negligence, use on a current or voltage other than that stamped on the nameplate or by use of other than genuine Majestic” cones.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals