1. The device interface as below:

1. RESET button: When the system runs normally, Press this button 5 to 10 seconds system will be reset
2. LAN1 port: Support Non-Standard POE 24V power input and Data communication.
3. LAN2 port: Data communication.

2. Instructions

1. This product is free setting for WEB, Power on devices A &B, The device will connect by themself, Needn’t setting for WEB.
2. Device are supports one to one or one to more for build network.

3. Device Building Diagram
  1. Connected The non-standard POE 24V power port with the CPE LAN1 port, for power input.
    Connected power adapter Lan port with PC(or other device) network port.

2. The Building Diagram as follows

CPE350S - Building diagram

Bridge settings:POE port connect to the bridge LAN1 (near reset button) power supply, LAN port connected to the computer network port.

4 Landing

1. After power-on, Connect device LAN2 port to the PC network port, Added IP address and subnet mask of 192.168.255.X segment in PC

2. Open your browser, and input the login IP address of the device (if the device is A enter:http://192.168.255.1; if the device is a B Enter http://192.168.255.2) and press Enter for login WEB Management interface.
In order to ensure the best display for WEB, Make sure to use the latest version

3. In the login window to enter a user name and password (the default are both: admin), and press the “OK” button.
4. After successful login into the bridge configuration interface

CPE350S - Landing 3

5. Using schematic

1. One to One is used for connection between two devices.
2. Onet to More is used for connection between One device A and more devices B

CPE350S - Using schematic 1

A device configuration

1. Enter the interface of [Bridge Set]
2. Bridge mode is set to mode A
3. Set the ID number (The ID number of device A is same with pairing device B)
4. After Press the [Application settings] Buttom the configuration is effective

B device configuration

1. Enter the interface of [Bridge Set]
2. Bridge mode is set to mode B
3. Set the ID number (The ID number of device B is same with pairing device A)
4. After Press the [Application settings] Buttom the configuration is effective

Note: 1. For One-to-many Setting. The ID number must be same for A device and more devices B
2. For more “One-to-many Setting”. Keep the ID number are different, for this can Avoid connecting to each other.

DIP CPE

1. The Move switch’s direction means the state, Move switch frist Silkscreen A & B is Working mode of bridge, And the second to fourth Silkscreen number is “Num”
2. The Silkscreen A & B is Working mode of bridge, A is Master connect to NVR, B is Slave connect to Camera or other device.
3. A & B’s Num is same, Device will connect by themself and support 1 A connect more B
4. Device A’s IP address is same with Num, Device B’s IP address is 200+code, For example Num = 100 A IP 192.168.255.100, And B IP 192.168.255.200
5. When Move switch is ok, the LED will power on too, When device is running you wan to use Move switch, after you must restart device the config will be ok

6. The WEB set can close Move switch function. after Move switch function is close, The device will come back to A, B mode, As below picture:

CPE350S - Wireless settings

Code| Matching ID
5.8G| A ip
192.168.255.(100+code)| B ip
200+ code
---|---|---|---
0 (000)| 36| 1| 100| 200
1 (100)| 40| 7| 101| 201
2 (020)| 44| 13| 102| 202
3 (120)| 48| 80| 103| 203
4 (004)| 149| 95| 104| 204
5 (104)| 153| 99| 105| 205
6 (024)| 157| 105| 106| 206
7 (124)| 161| 0| 107| 207

Digital Display Wireless Bridge

CPE350S - Wireless bridge 1

  1. Switch Computer Camera Usually near NVR
  2. PoE Adapter
  3. Digital Bridge-A Master Mode
    (IPC receiver)

CPE350S - Wireless bridge 2

  1. Switch Computer Camera At the IPC end
  2. PoE Adapter
  3. Digital Bridge-B Slave Mode
    (IPC transmitter)

1. First Set A B A-B mode DIP switch, led L appears and blinks. After the disappearance of L shows an arrangement remain successful.

2. The reset button to set the led digital display, click the startup configuration status, then click the automatic increase. Can be continuously increased

3. Assume that a pair of bridges with a number of 1 is configured
After A set to 1, after the B set to 1, during the LED will flash, L application configuration appears blinking, wait, L foot after flashing into a digital 1, 1 will continue to flash until the A, B are connected After the success, the LED display 1 is always on, not flashing, indicating that the AB has been successfully networked.

CPE350S - Wireless bridge 3

Link Bridge connection is successful, link lights, not connected Off
LAN1 Turning on the lighting data, the communication flashing, off data

nowhere
LAN2| Turning on the lighting data, the communication flashing, off data nowhere
PWR| Power indicator, power on
LED| Display H, expressed configured to manually set state
LED| L displayed and flashes, represents settings
LED| Flashing, it indicates to modify the configuration, or is connected to the
Round light| A, B status lights, light that is not mode A, mode B light that
RST| 1-5s press, led digital automatic increase, 0-F from circulation
RST| Press over 10s, release the reset, the system automatically restart

LED

| A IP| B IP| 2.4 ID| 5.8 ID
---|---|---|---|---
0| 192.168.255.100| 192.168.255.200| 0|

0

1

| 192.168.255.101| 192.168.255.201| 1| 165
2| 192.168.255.102| 192.168.255.202| 2|

161

3

| 192.168.255.103| 192.168.255.203| 3| 157
4| 192.168.255.104| 192.168.255.204| 4|

153

5

| 192.168.255.106| 192.168.255.205| 5| 149
6| 192.168.255.106| 192.168.255.206| 6|

48

7

| 192.168.255.107| 192.168.255.207| 7| 44
8| 192.168.255.108| 192.168.255.208| 8|

40

9

| 192.168.255.109| 192.168.255.209| 9| 36
a| 192.168.255.110| 192.168.255.210| 10|

140

b

| 192.168.255.111| 192.168.255.211| 11| 132
C| 192.168.255.112| 192.168.255.212| 13|

124

D

| 192.168.255.113| 192.168.255.213| 96| 116
E| 192.168.255.114| 192.168.255.214| 50|

108

F

| 192.168.255.115| 192.168.255.215| 55|

100

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals