Shenzhen Kangda Xin Intelligent Network Technology CPE350S Indoor/Outdoor Enterprise Wireless Bridge Instruction Manual
- June 5, 2024
- Shenzhen Kangda Xin Intelligent Network Technology
Table of Contents
The Wireless Bridge Manual
1. The device interface as below:
1. RESET button: When the system runs normally, Press this button 5 to 10
seconds system will be reset
2. LAN1 port: Support Non-Standard POE 24V power input and Data
communication.
3. LAN2 port: Data communication.
2. Instructions
1. This product is free setting for WEB, Power on devices A &B, The device
will connect by themself, Needn’t setting for WEB.
2. Device are supports one to one or one to more for build network.
3. Device Building Diagram
- Connected The non-standard POE 24V power port with the CPE LAN1 port, for power input.
Connected power adapter Lan port with PC(or other device) network port.
2. The Building Diagram as follows
Bridge settings:POE port connect to the bridge LAN1 (near reset button) power supply, LAN port connected to the computer network port.
4 Landing
1. After power-on, Connect device LAN2 port to the PC network port, Added IP address and subnet mask of 192.168.255.X segment in PC
2. Open your browser, and input the login IP address of the device (if the
device is A enter:http://192.168.255.1; if the device is a B Enter
http://192.168.255.2) and press Enter for login WEB Management interface.
In order to ensure the best display for WEB, Make sure to use the latest
version
3. In the login window to enter a user name and password (the default are
both: admin), and press the “OK” button.
4. After successful login into the bridge configuration interface
5. Using schematic
1. One to One is used for connection between two devices.
2. Onet to More is used for connection between One device A and more
devices B
A device configuration
1. Enter the interface of [Bridge Set]
2. Bridge mode is set to mode A
3. Set the ID number (The ID number of device A is same with pairing
device B)
4. After Press the [Application settings] Buttom the configuration is
effective
B device configuration
1. Enter the interface of [Bridge Set]
2. Bridge mode is set to mode B
3. Set the ID number (The ID number of device B is same with pairing
device A)
4. After Press the [Application settings] Buttom the configuration is
effective
Note: 1. For One-to-many Setting. The ID number must be same for A device
and more devices B
2. For more “One-to-many Setting”. Keep the ID number are different, for
this can Avoid connecting to each other.
DIP CPE
1. The Move switch’s direction means the state, Move switch frist
Silkscreen A & B is Working mode of bridge, And the second to fourth
Silkscreen number is “Num”
2. The Silkscreen A & B is Working mode of bridge, A is Master connect to
NVR, B is Slave connect to Camera or other device.
3. A & B’s Num is same, Device will connect by themself and support 1 A
connect more B
4. Device A’s IP address is same with Num, Device B’s IP address is
200+code, For example Num = 100 A IP 192.168.255.100, And B IP
192.168.255.200
5. When Move switch is ok, the LED will power on too, When device is
running you wan to use Move switch, after you must restart device the config
will be ok
6. The WEB set can close Move switch function. after Move switch function is close, The device will come back to A, B mode, As below picture:
Code| Matching ID
5.8G| A ip
192.168.255.(100+code)| B ip
200+ code
---|---|---|---
0 (000)| 36| 1| 100| 200
1 (100)| 40| 7| 101| 201
2 (020)| 44| 13| 102| 202
3 (120)| 48| 80| 103| 203
4 (004)| 149| 95| 104| 204
5 (104)| 153| 99| 105| 205
6 (024)| 157| 105| 106| 206
7 (124)| 161| 0| 107| 207
Digital Display Wireless Bridge
- Switch Computer Camera Usually near NVR
- PoE Adapter
- Digital Bridge-A Master Mode
(IPC receiver)
- Switch Computer Camera At the IPC end
- PoE Adapter
- Digital Bridge-B Slave Mode
(IPC transmitter)
1. First Set A B A-B mode DIP switch, led L appears and blinks. After the disappearance of L shows an arrangement remain successful.
2. The reset button to set the led digital display, click the startup configuration status, then click the automatic increase. Can be continuously increased
3. Assume that a pair of bridges with a number of 1 is configured
After A set to 1, after the B set to 1, during the LED will flash, L
application configuration appears blinking, wait, L foot after flashing into a
digital 1, 1 will continue to flash until the A, B are connected After the
success, the LED display 1 is always on, not flashing, indicating that the AB
has been successfully networked.
Link | Bridge connection is successful, link lights, not connected Off |
---|---|
LAN1 | Turning on the lighting data, the communication flashing, off data |
nowhere
LAN2| Turning on the lighting data, the communication flashing, off data
nowhere
PWR| Power indicator, power on
LED| Display H, expressed configured to manually set state
LED| L displayed and flashes, represents settings
LED| Flashing, it indicates to modify the configuration, or is connected
to the
Round light| A, B status lights, light that is not mode A, mode B light that
RST| 1-5s press, led digital automatic increase, 0-F from circulation
RST| Press over 10s, release the reset, the system automatically restart
LED
| A IP| B IP| 2.4 ID| 5.8 ID
---|---|---|---|---
0| 192.168.255.100| 192.168.255.200| 0|
0
1
| 192.168.255.101| 192.168.255.201| 1| 165
2| 192.168.255.102| 192.168.255.202| 2|
161
3
| 192.168.255.103| 192.168.255.203| 3| 157
4| 192.168.255.104| 192.168.255.204| 4|
153
5
| 192.168.255.106| 192.168.255.205| 5| 149
6| 192.168.255.106| 192.168.255.206| 6|
48
7
| 192.168.255.107| 192.168.255.207| 7| 44
8| 192.168.255.108| 192.168.255.208| 8|
40
9
| 192.168.255.109| 192.168.255.209| 9| 36
a| 192.168.255.110| 192.168.255.210| 10|
140
b
| 192.168.255.111| 192.168.255.211| 11| 132
C| 192.168.255.112| 192.168.255.212| 13|
124
D
| 192.168.255.113| 192.168.255.213| 96| 116
E| 192.168.255.114| 192.168.255.214| 50|
108
F
| 192.168.255.115| 192.168.255.215| 55|
100
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>