CONTROL b yWEB X-401W Dual Relay and Input Module Installation Guide

June 5, 2024
CONTROL b yWEB

CONTROL b yWEB X-401W Dual Relay and Input Module

Specifications

  • Model: X-401W
  • Power Supply: Vin+ Vin- Vout Gnd
  • Factory Default Settings:
    • IP Address: 192.168.1.2
    • Subnet Mask: 255.255.255.0
    • Control Page Web Address: http://192.168.1.2
    • Control Password: (no password set)
    • Setup Page Web Address: http://192.168.1.2/setup.html
    • Setup Username: admin
    • Setup Password: web relay (all lower case)

Product Usage Instructions

Basic Setup Steps

  1. Power the module and connect via ethernet to a computer.
  2. Set the IP address on the computer to the same network as the module (e.g., 192.168.1.50). Remember to restore computer settings after setup.
  3. To configure the module, open a web browser and enter: http://192.168.1.2/setup.html
  4. In General Settings under WiFi, enter the WiFi settings.
  5. Assign the module a permanent IP address or enable DHCP.
  6. Restart the module for the settings to take effect.

Pinout Diagram

Power Supply Input + Power Supply Input – Vin – 0.7V (or 11V with POE) Ground (common) In1+ Optically-Isolated Input 1 + In1In2+ Optically-Isolated Input 1 Optically-Isolated Input 2+ In21C 1NC 1NO 2C 2NC 2NO Optically-Isolated Input 2Relay 1 common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 Normally Open

FAQ

  • Q: How can I reset the module to factory default settings?
  • A: To reset the module to factory default settings, access the setup page web address (http://192.168.1.2/setup.html), log in with the setup username and password, and look for the option to reset to factory defaults.
  • Q: How do I change the WiFi settings of the module?
  • A : To change the WiFi settings of the module, access the setup page web address (http://192.168.1.2/setup.html) and navigate to the General Settings under WiFi where you can enter and modify the WiFi settings as required.

Basic Setup Steps

  1. Power the module and connect via ethernet to a computer.
  2. Set the IP address on a computer to the same network as the module.(Ex: 192.168.1.50) Note: restore computer settings after setup.
  3. To configure the module, open the web browser and enter: http://192.168.1.2/setup.html
  4. In General Settings under WiFi, enter the WiFi settings.
  5. Assign the module a permanent IP address or enable DHCP.
  6. Restart the module for the settings to take effect.

Factory Default Settings

  • IP Address: 192.168.1.2
  • Subnet Mask: 255.255.255.0
  • Control Page Web Address: http://192.168.1.2
  • Control Password: (no password set)
  • Setup Page Web Address: http://192.168.1.2/setup.html Setup Username: admin
  • Setup Password: web relay (all lowercase)

Pinout Diagram

  • Power Supply Input +
  • Power Supply Input –
  • Vin – 0.7V (or 11V with POE)
  • Ground (common)
  • Optically-Isolated Input 1 +
  • Optically-Isolated Input 1 –
  • Optically-Isolated Input 2+
  • Optically-Isolated Input 2-
  • Relay 1 Common
  • Relay 1 Normally Closed
  • Relay 1 Normally Open
  • Relay 2 Common
  • Relay 2 Normally Closed
  • Relay 2 Normally Open