CONTROL b yWEB X-401W Dual Relay and Input Module Installation Guide
- June 5, 2024
- CONTROL b yWEB
Table of Contents
CONTROL b yWEB X-401W Dual Relay and Input Module
Specifications
- Model: X-401W
- Power Supply: Vin+ Vin- Vout Gnd
- Factory Default Settings:
- IP Address: 192.168.1.2
- Subnet Mask: 255.255.255.0
- Control Page Web Address: http://192.168.1.2
- Control Password: (no password set)
- Setup Page Web Address: http://192.168.1.2/setup.html
- Setup Username: admin
- Setup Password: web relay (all lower case)
Product Usage Instructions
Basic Setup Steps
- Power the module and connect via ethernet to a computer.
- Set the IP address on the computer to the same network as the module (e.g., 192.168.1.50). Remember to restore computer settings after setup.
- To configure the module, open a web browser and enter: http://192.168.1.2/setup.html
- In General Settings under WiFi, enter the WiFi settings.
- Assign the module a permanent IP address or enable DHCP.
- Restart the module for the settings to take effect.
Pinout Diagram
Power Supply Input + Power Supply Input – Vin – 0.7V (or 11V with POE) Ground (common) In1+ Optically-Isolated Input 1 + In1In2+ Optically-Isolated Input 1 Optically-Isolated Input 2+ In21C 1NC 1NO 2C 2NC 2NO Optically-Isolated Input 2Relay 1 common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 Normally Open
FAQ
- Q: How can I reset the module to factory default settings?
- A: To reset the module to factory default settings, access the setup page web address (http://192.168.1.2/setup.html), log in with the setup username and password, and look for the option to reset to factory defaults.
- Q: How do I change the WiFi settings of the module?
- A : To change the WiFi settings of the module, access the setup page web address (http://192.168.1.2/setup.html) and navigate to the General Settings under WiFi where you can enter and modify the WiFi settings as required.
Basic Setup Steps
- Power the module and connect via ethernet to a computer.
- Set the IP address on a computer to the same network as the module.(Ex: 192.168.1.50) Note: restore computer settings after setup.
- To configure the module, open the web browser and enter: http://192.168.1.2/setup.html
- In General Settings under WiFi, enter the WiFi settings.
- Assign the module a permanent IP address or enable DHCP.
- Restart the module for the settings to take effect.
Factory Default Settings
- IP Address: 192.168.1.2
- Subnet Mask: 255.255.255.0
- Control Page Web Address: http://192.168.1.2
- Control Password: (no password set)
- Setup Page Web Address: http://192.168.1.2/setup.html Setup Username: admin
- Setup Password: web relay (all lowercase)
Pinout Diagram
- Power Supply Input +
- Power Supply Input –
- Vin – 0.7V (or 11V with POE)
- Ground (common)
- Optically-Isolated Input 1 +
- Optically-Isolated Input 1 –
- Optically-Isolated Input 2+
- Optically-Isolated Input 2-
- Relay 1 Common
- Relay 1 Normally Closed
- Relay 1 Normally Open
- Relay 2 Common
- Relay 2 Normally Closed
- Relay 2 Normally Open
CONYTACT
- www.ControlByWeb.com/support
- www.ControlByWeb.com
- 1681 West 2960 South, Nibley, UT 84321, USA