LUCELL EGE-120-BZ-FP Aegis Cabinet User Manual

June 5, 2024
LuCell

LUCELL EGE-120-BZ-FP Aegis Cabinet

Safety Precautions

Safety precautions are to prevent any unexpected risk or damage. Please read before use.

| ~ Be careful when opening and closing door. Finger or objects may get stuck.
~ Keep children away when operating the safe.
~ Do not hit edge of safe to avoid injury.
---|---
| ~ Safe is very heavy. Be careful when moving or installing safe to avoid injury.
~ Firmly fix safe to ground when installing. When moving safe, engage professionals if needed.
~ Improper handling of safe can cause damage to floor.
| ~ Avoid placing fragile objects, such as ceramic or glass, on safe. They may fall and cause injury
| ~ Place safe on a flat surface. Otherwise, safe door may not close.

Before Use

  • Product may malfunction if foreign metal substances or moisture enter keypad.
  • Do not scratch keypad and fingerprint scanner with any sharp object.
  • Do not apply excessive force on the keypad.
  • Avoid exposure to any chemicals (gasoline, benzene, solvent, acetone, thinner, etc.)
  • Avoid direct fire or heat.
  • Remove batteries when safe is not in use for long periods.
  • Excessive force to safe handle may cause breakage.
  • Safe can be broken into by cutting or blazing tools. Our Company is not liable for any stolen items.

Keypad Overview

Outside

Inside

How to use Alarm

  1. Use the `On/Off’ switch on the Alarm to activate/deactivate.
  2. Use 1.5volt alkaline batteries (AAAx3).

Keypad Lock Mode

Battery Replacement

Attention
  • After replacing batteries, confirm safe is working properly before closing door.
  • Use 1.5Volt Alkaline batteries (AA x 4). (No lithium, rechargeable or heavy duty batteries.)

Opening / Closing door

The factory default password of this safe has been set as 1 2 3 4 5 6. It is highly recommended to change.

  •  Press START button twice for security mode to hide password.
  • Press START button to cancel password entry.
  • Safe must be opened within 3 ~ 4 seconds.
  • “Err-03” indicates incorrect password.
  • 5 consecutive incorrect password will sound alarm for 3 mintues.
  • Press START button can enter correct password to stop the alarm.

Changing Password

Combination of 4 ~ 20 digit code can be used as a password

Attention Safe can be programmed with up to 2 sets of passwords.

Volume Control

Make sure the door is open during this process.

Register fingerprints Maximum of 10 fingerprints

Attention
Make sure each new fingerprint works before closing the door.

Delete fingerprints

Attention
“no-Fr” will be displayed when no fingerprint was registered.

Opening the safe with fingerprint

– If no fingerprint was registered, the safe can only be opened by the password.
– “Err-04” is shown when the finger is not positioned correctly on the biometric reader, or an unauthorised fingerprint attempts access.
– Dirt, sweat, injuries, cuts, scars, or wound may cause “Err-04” message to appear.

Bolt-Down Instructions

NOTE: – Anchor bolt should be fitted into floor BEFORE safe is placed over. – Bolt may need to be cut. – Cover is provided for fire resistant safe. Place cover over hole.

  1. Please see drawing in the left. Anchor bolt may vary according to model.
    A (Anchor Size)| M12 x 145L
    ---|---
    B (Diameter of hole)| O 19.6
  2. After checking the anchor bolt size ‘A’, drill a hole with ‘B’ size into the concrete flooring to a depth of 50mm (2inch).
  3. Insert anchor bolt and pipe into the hole.
  4. Place flat washer and nut on anchor bolt and tighten (14mm wrench) to allow anchor pipe to expand and secure into the floor.
  5. Remove nut and washer from anchor bolt. 6. Place safe on to p pf anchor bolt through centre hole in bottom of safe. 7. Place washer, spring washer and nut on anchor bolt amd tighten.

Troble shooting

Situation Possible Causes Measures
No response when START button pressed Dead batteries Replace new Alkaline

batteries
Incorrect insertion of batteries| Confirm correct insertion of batteries
Keypad lock mode ON| Press START for 3 seconds to deactivate keypad lock mode
Circuit error| Contact Service Centre
Alarm continues ringing and safe does not work| 5 times wrong password input| Enter correct password or wait 3 mintues unttl alarm stops
“Err-03” message appears| Incorrect password| Enter correct password
Does not open when “OPEN” is displayed| Low battery| Replace new Alkaline batteries
Incorrect turning of handle/key| Turn handle clockwise
Lock equipment error| Contact Service Centre
Cannot change password| Exceeded time limit during password change| Enter password within 5 seconds
Keypad malfunction| Contact Service Centre
Button error| Contact Service Centre
“Lo_bAt” message appears| Low battery| Replace new Alkaline batteries
“Act” message appears| Keypad lock mode ON| Press START for 3 seconds to deactivate keypad lock mode
Forgot password| | Contact Service Centre
Display Error_Err-04| Unregistered fingerprint| Try the registered fingerprint again
Display Error_Err-05| This message is shown when the safe was forcefully opened or there is a sensor problem| – Input the password
– if the message repeats, contact Service Centre
Display Error_Err-11| Fingerprint operation failure| – Try again or register new, clear fingerprint of another finger
– if the message repeats, contact Service Centre
Display Error_Err-13| Fingerprint module has problem| Contact Service Centre

Distributed by: .
DURO INTERNATIONAL PTE LTD

Hotline: 6745 6800
email: enq@duro.com.sg

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LuCell User Manuals

Related Manuals