LUCELL EGE-120-BZ-FP Aegis Cabinet User Manual
- June 5, 2024
- LuCell
Table of Contents
- Safety Precautions
- Before Use
- Keypad Overview
- Outside
- Inside
- Keypad Lock Mode
- Battery Replacement
- Opening / Closing door
- Changing Password
- Volume Control
- Register fingerprints Maximum of 10 fingerprints
- Delete fingerprints
- Opening the safe with fingerprint
- Bolt-Down Instructions
- Troble shooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LUCELL EGE-120-BZ-FP Aegis Cabinet
Safety Precautions
Safety precautions are to prevent any unexpected risk or damage. Please read before use.
| ~ Be careful when opening and closing door. Finger or objects may get stuck.
~ Keep children away when operating the safe.
~ Do not hit edge of safe to avoid injury.
---|---
| ~ Safe is very heavy. Be careful when moving or installing safe to avoid
injury.
~ Firmly fix safe to ground when installing. When moving safe, engage
professionals if needed.
~ Improper handling of safe can cause damage to floor.
| ~ Avoid placing fragile objects, such as ceramic or glass, on safe. They may
fall and cause injury
| ~ Place safe on a flat surface. Otherwise, safe door may not close.
Before Use
- Product may malfunction if foreign metal substances or moisture enter keypad.
- Do not scratch keypad and fingerprint scanner with any sharp object.
- Do not apply excessive force on the keypad.
- Avoid exposure to any chemicals (gasoline, benzene, solvent, acetone, thinner, etc.)
- Avoid direct fire or heat.
- Remove batteries when safe is not in use for long periods.
- Excessive force to safe handle may cause breakage.
- Safe can be broken into by cutting or blazing tools. Our Company is not liable for any stolen items.
Keypad Overview
Outside
Inside
How to use Alarm
- Use the `On/Off’ switch on the Alarm to activate/deactivate.
- Use 1.5volt alkaline batteries (AAAx3).
Keypad Lock Mode
Battery Replacement
Attention
- After replacing batteries, confirm safe is working properly before closing door.
- Use 1.5Volt Alkaline batteries (AA x 4). (No lithium, rechargeable or heavy duty batteries.)
Opening / Closing door
The factory default password of this safe has been set as 1 2 3 4 5 6. It is
highly recommended to change.
- Press START button twice for security mode to hide password.
- Press START button to cancel password entry.
- Safe must be opened within 3 ~ 4 seconds.
- “Err-03” indicates incorrect password.
- 5 consecutive incorrect password will sound alarm for 3 mintues.
- Press START button can enter correct password to stop the alarm.
Changing Password
Combination of 4 ~ 20 digit code can be used as a password
Attention Safe can be programmed with up to 2 sets of passwords.
Volume Control
Make sure the door is open during this process.
Register fingerprints Maximum of 10 fingerprints
Attention
Make sure each new fingerprint works before closing the door.
Delete fingerprints
Attention
“no-Fr” will be displayed when no fingerprint was registered.
Opening the safe with fingerprint
– If no fingerprint was registered, the safe can only be opened by the
password.
– “Err-04” is shown when the finger is not positioned correctly on the
biometric reader, or an unauthorised fingerprint attempts access.
– Dirt, sweat, injuries, cuts, scars, or wound may cause “Err-04” message to
appear.
Bolt-Down Instructions
NOTE: – Anchor bolt should be fitted into floor BEFORE safe is placed over. –
Bolt may need to be cut. – Cover is provided for fire resistant safe. Place
cover over hole.
- Please see drawing in the left. Anchor bolt may vary according to model.
A (Anchor Size)| M12 x 145L
---|---
B (Diameter of hole)| O 19.6 - After checking the anchor bolt size ‘A’, drill a hole with ‘B’ size into the concrete flooring to a depth of 50mm (2inch).
- Insert anchor bolt and pipe into the hole.
- Place flat washer and nut on anchor bolt and tighten (14mm wrench) to allow anchor pipe to expand and secure into the floor.
- Remove nut and washer from anchor bolt. 6. Place safe on to p pf anchor bolt through centre hole in bottom of safe. 7. Place washer, spring washer and nut on anchor bolt amd tighten.
Troble shooting
Situation | Possible Causes | Measures |
---|---|---|
No response when START button pressed | Dead batteries | Replace new Alkaline |
batteries
Incorrect insertion of batteries| Confirm correct insertion of batteries
Keypad lock mode ON| Press START for 3 seconds to deactivate keypad lock mode
Circuit error| Contact Service Centre
Alarm continues ringing and safe does not work| 5 times wrong password input|
Enter correct password or wait 3 mintues unttl alarm stops
“Err-03” message appears| Incorrect password| Enter correct password
Does not open when “OPEN” is displayed| Low battery| Replace new Alkaline
batteries
Incorrect turning of handle/key| Turn handle clockwise
Lock equipment error| Contact Service Centre
Cannot change password| Exceeded time limit during password change| Enter
password within 5 seconds
Keypad malfunction| Contact Service Centre
Button error| Contact Service Centre
“Lo_bAt” message appears| Low battery| Replace new Alkaline batteries
“Act” message appears| Keypad lock mode ON| Press START for 3 seconds to
deactivate keypad lock mode
Forgot password| | Contact Service Centre
Display Error_Err-04| Unregistered fingerprint| Try the registered fingerprint
again
Display Error_Err-05| This message is shown when the safe was forcefully
opened or there is a sensor problem| – Input the password
– if the message repeats, contact Service Centre
Display Error_Err-11| Fingerprint operation failure| – Try again or register
new, clear fingerprint of another finger
– if the message repeats, contact Service Centre
Display Error_Err-13| Fingerprint module has problem| Contact Service Centre
Distributed by: .
DURO INTERNATIONAL PTE LTD
Hotline: 6745 6800
email: enq@duro.com.sg
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>