ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers User Manual

June 5, 2024
Alorair

ALORAIR logo Sentinel HD55 Basement Crawl Space Dehumidifiers
User ManualALORAIR Sentinel HD55 Basement Crawl Space
Dehumidifiers

Sentinel HD55 Installation & Operations Manual
AlorAir Solutions INC.
Add:14752 Yorba Ct Chino CA 91710
US Tel: 888-990-7469
E-mail: [email protected] 

Warranty Registration

Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier comes with an extended warranty plan. To register, simply fill out and return the warranty form provided in the dehumidifier box. Be sure to note your dehumidifier serial number as you will need it for registration.

Safety Notes

  • The Sentinel Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used all I lability reverts to the owner and the warranty is voided.
  • Sentinel Dehumidifiers should only be maintained and repaired by a qualified technician.
  • Sentinel Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
  • Always unplug the dehumidifier before moving.
  • If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
  • To ensure proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12″ clearance and the discharge requires a minimum of 36″ clearance.
  •  The best option for proper diffusion of air throughout the room is to have the discharge blowing away from a wall and the inlet pulling air parallel to a wall.
  • Do not insert your fingers or any object into the inlet or discharge.
  • All work on the dehumidifier should be done with the unit “off” and unplugged.
  • Do not use water to clean the exterior of the machine. To the dean unit, unplug from power, then use a damp cloth to wipe the exterior.
  • Do not stand on the machine or use it as a device to hang clothes.

Identification

For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific machine.
Model Number: Sentinel HD55
Serial Number…………………………………….
Date of Purchase-………………………………
For additional questions concerning your dehumidifier, the following options are available:
• Contact your installing contractor
• E-mail: [email protected]
Electrical Supply
Power Supply: 115 V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp
WARNING: 240 Volts AC may cause serious injury from electric shock.
To reduce the risk of injury:

  1. Disconnect electrical power before servicing
  2. Only plug the unit into a grounded electrical circuit
  3. Do not use an extension cord.
  4. Do not use a plug adapter

Principle of Operation

The Sentinel Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.

Installation

The area to be controlled should be sealed with a vapor barrier. If the unit is installed in a crawlspace, all vents should be sealed.
WARNING Do not install your dehumidifier in a corrosive environment. Some liquid-vapor barriers dry via “solvent evaporation”. Always make sure that the barrier is completely dry and the area is thoroughly ventilated before installing a dehumidifier.
Step #1: Place the dehumidifier on a level surface.
Do not place it directly on the vapor barrier. For example, use blocks, or pavers to create a level surface.
If the unit is handled in such a manner that the compressor did not remain in the upright position, it is necessary to place on a level surface and wait a minimum of 2 hours before turning the unit “on”
NOTE: Sentinel HD55 Dehumidifiers can’t sit directly on the floor unless the unit is feeding directly into a sump pump next to it. The elevation is required to allow gravity flow of condensate water drain.
Step #2: Set Up Drain Line
The drain line should be routed to a suitable drain on the outside. It must flow down to a drain without any loops, dips, or valleys.
Recommended Drain Option-Transition to PVC Pipe

  1. Cut a piece of 3/4″ OD PVC that is approx. 6″ long.
  2. Insert PVC into a 3/4″ elbow, then attach to a 3/4″ OD length of PVC to drain. (Note: Keep the length of PVC drain pipe to a minimum)
  3. Insert the open end of the tubing into the 3/4″ pipe so that it does not extend into the elbow fitting. For proper flow, a minimum downward slope of 1″ per 10′ run is required. (Note: If a proper downward angle is not possible, then it is recommended to use a Sentinel HDi90 which includes an integrated pump. Alternatively, you can use an external condensate pump).
  4. Support the PVC tubing so that it maintains a smooth downward flow to drain.
  5. Always test the drain before leaving the installation area.
    ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers -
fig

Step #3: Plug unit into 15 amp grounded circuit.

Key Functions

1. Power Key
• Use this button to turn the dehumidifier on and oft Press once to turn the machine on. You will hear 2 beeps and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one-minute fan delay on shut-down.
2. Arrow Buttons
Use the up and down arrow button to set the desired humidity setpoint on the display screen.
The setpoint can be any number between 36-90%. Creating a set point means that when the indoor humidity is lower than the set point, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate.
NOTE: The humidity levels displayed are approximate only (+/- 5%)
3. Continuous Mode at ,

  • To switch into the continuous mode, simply use the down arrow to set the humidity below 36%. The Cont. light should illuminate green on the display board to indicate that you have successfully switched into continuous mode. The display screen will show “CO”.
  • When set to continuous, the dehumidifier will run constantly, regardless of the humidity level. To stop the machine, turn the unit off or switch back to normal humidistat operation. If you would like to switch back to normal humidistat operation, simply move the setpoint above 36%.

4. Central Control

  • This mode is not applicable on the Sentinel HD55.

5. Auxiliary Terminals A5/A6

  • The A5/A6 on the terminal strip can be used as a water level warming switch for external condensate pumps.
    If an external pump is connected, the pump must have a self-contained power supply and a water level signal line.

Indicator Lights

  1. Humidity Display Screen
    • The display screen has two functions:

  2. When the unit is powered on, it shows the humidity of the space.

  3. While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to the current humidity level.

2. Power Indicator Light

  • This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is “off” prior to performing any service.

3. Continuous Mode/AutoDefrost Light

  • When this light illuminates green, it indicates that the dehumidifier is set to the continuous operation mode.
  • When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup.

4. Compressor Light

  • When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
  • Once the compressor light switches to green, it indicates the compressor is in working status.

Remote Control Instructions

Sentinel Dehumidifiers can be controlled using an optional remote accessory. The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via a 25′ CAT 5 cable. The remote control contains an integrated sensor that gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote. For example, the dehumidifier could be installed in a laundry room and ducked into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user. Mother useful application for the remote control is if the dehumidifier is in an area that’s difficult to access on a regular basis. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.
ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
2

  1. On/off (Power)Button
    Press the on/off button and the machine will start running (one beep). Press the button again to turn the machine off.

  2. Up Button • / Down Button
    • Use the Up and Down arrow buttons to adjust the humidity level.

  3. Mode M
    Use the Mode button to switch between dehumidification and a ducted application.
    • The symbol on the display board indicates the sensor on the remote control is being utilized.
    • The symbol on the display board indicates the sensor on the dehumidifier is being utilized.

  4. Temperature T
    Press the temperature button to display the current temperature on the screen. Press the button again to tum off the display.

  5. Continuous C
    Press this button to switch the unit into continuous mode. coot. will appear on the display to indicate continuous mode.

  6. Drain Pump P
    Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored. THIS FUNCTION IS ONLY AVAILABLE ON THE Sentinel HDi90 model.
    NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.

Operating Instructions

  1. Start the Machine Press the power key to turn the machine on.

  2. Adjust the Settings Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).

  3. Stop the Machine Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has turned off.
    NOTE: Do not disconnect the power cord to force the unit to stop. Always use the power button.

  4. Water Drainage During normal operation, the Sentinel HD55 will automatically drain by the force of gravity. If you want to move or store your machine, wait at least 10 minutes to allow the machine to completely defrost, then lean the unit gently towards the drain to ensure that it is completely drained.

Sentinel HD55 Diagram
Front View ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers -
fig 4

Back viewALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
5

Maintenance

Always unplug the unit before doing any maintenance.
Cleaning the machine body
Use a soft damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
Cleaning the filter

  1. Unplug the unit.
  2. Slide-out the filter.
  3. Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
  4. Be sure the filter is completely dry before restarting the unit.”
    ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
6

Coil Maintenance

  • Once per year, clean the coils with an approved coil cleaner
  • Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.

Dehumidifier Storage

If the unit will be stored for an extended period of time, complete the following steps:

  1. Turn off the unit and allow it to dry
  2. Wrap and secure the power cord.
  3. Cover the filter mesh.
  4. Store in a clean, dry space.

Ducted Applications

Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. The supply grille is designed for 6″ flex ducting. Be sure to secure the ducting with tie wrap. Also, keep in mind that the supply ducting can be screwed into an adapter if necessary.
Ducting Installation
• Maximum length for ducting= 6′

Note: The supply duct adapter is standard on all units.

Removing Supply Duct Adapter
If it is necessary to remove the adapter, place your hand at bottom of the adapter and use your fingers to pull out and down on the base of the adapter. This will lift hooks out of cover holes.
ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
7 Installing Supply Duct Adapter
To install the adapter, line up with holes on the side of the unit and push up from the base of the adapter.
ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
8
Flex Duct Installation
Rotate the flex duct counter-clockwise
ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
9 Flex Duct Removal
Rotate flex duct clockwise.
ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifiers - fig
10

Troubleshooting

Symptom Cause Solution
Machine Won’t Run Power Supply Verify that there is the power to the outlet

and that the plug is properly installed in the outlet
Room Temperature Over 104° F (Display HI) or Below 33.8° F (Display LO)| The unit is outside the operating temperature range. Modify the room conditions so the temperature is between 33.8° – um’ F and operation will commence.
Low Air Flow| Air Filter Is Clogged| Clean the filter mesh according to the instructions listed in the manual.
Air Inlet or Outlet is Blocked.| Clear the blockage from the inlet or outlet.
Loud Noise| Machine Is Not Level| Move the dehumidifier to flat, firm ground.
Filter Mesh is Blocked| Clean the filter mesh according to the instructions listed in the manual.
Trouble Code E:1| E1=Humidity Sensor Issues| Check to ensure that the wire is connected at both ends. If no issues are visible, the sensor may be faulty.
Trouble Code: HI or LO| Room Temperature Over 104° F or Below 33.8° F(Display LO)| The unit is outside the operating temperature range. Modify the room conditions so the temperature is between 33.8′ – 104′ F and operation will commence.lf room conditions are within the temperature range, replace the defective sensor.

Sentinel HD55 Spare parts

All Sentinel Models-Parts

Pam Description
S-100| Remote Control Package(cable+remote)
S-101| Remote Control
S-102| Remote Control Cable,25′
S-107| Flexible Supply Duct,72″
5-108| Main Control Board
S-109| Display Board
S-110| RH/Temperature Sensor
Sentinel HD55-Parts
Part# Description
S-500| Fan Motor
S-501| Complete Fan Assembly
S-502| Fan Capacitor
S-503| Compressor
S-504| Compressor Capacitor
S-505| Coil Assembly
S-506| Hot Gas Bypass Coil
5-608| RH/Temperature Sensor Cable
S-509| Display Cable
S-510| CAT 5 Prot Internal Cable
S-513| Foot, adjustable
Sentinel HD55-Filters
Part# Description
S-517| MERV-8 Filter
S-518| HEPA Filter
S-519| Carbon Filter

Limited Warranty

This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:
Six (6) Month parts and labor. This includes the shipment charges for replacement parts or units.
One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.
Three (3) years of parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included.
This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. Alorair Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or [email protected]. Proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in a normal household, commercial or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage includes scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with an OUTDOOR POOL invalidates or voids the limited warranty.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Alorair User Manuals

Related Manuals