Schlage Lock JFE109KPL Electronic Door Lock User Guide

June 5, 2024
Schlage Lock

User Guide
JBE105 Deadbolt, JFE105 Lever
JBE109 Connected Deadbolt, JFE109 Connected Lever

NOTE
You must press ( ) after entering a user code. Your lock will not recognize a user code until you press the lock button.

**Proper Use

**

  • Use four new AA alkaline batteries for the best performance.
  • Do not attempt to disassemble any internal components of the lockset. Doing so will void the limited warranty.
  • Do not drop or hit the lockset. Impact may result in permanent damage.
  • Do not use pins or sharp objects to press the keypad.

Care and Maintenance

  • Remove locks, or do not install locks, prior to painting your door.
  • Periodically clean with a mild cleaner and a soft cloth only. Do not use any abrasives or chemical products containing alcohol, benzene, or acids, and avoid using sharp or abrasive objects to clean this lockset.
  • Do not allow any water or liquids into the lockset.
  • JBE109: You must enter a valid user code after battery replacement. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops.

JBE105 Deadbolt and JBE109 Connected Deadbolt

How to Lock/Unlock

FROM INSIDE  FROM OUTSIDE

Lock

  • Turn thumb turn toward the door edge.

Unlock

  •  Turn thumb turn away from door edge.

| Lock
Insert key and turn until deadbolt engages.

  • Press

Unlock

  • Enter valid user code, then press
  • To manually unlock, insert a key and turn until deadbolt disengages.

JFE105 Lever

JFE105 Modes

Auto-Lock
Auto-Lock mode will automatically lock the door.| Turn the inside thumb turn to a horizontal position (pointing left or right) to set it to Auto- Lock mode.
Passage
Passage mode allows for free passage (lever is unlocked).| Turn the inside thumb turn to a vertical position (straight up and down) to set it to Passage mode.

How to unlock the door in Auto-Lock mode

  • Enter valid user code then press
  • To manually unlock, insert and rotate the key to a vertical position. With the key installed, turn the lever. Lever will remain unlocked until the key is removed.

How to unlock the door in Passage mode

  • Door is always unlocked.

JFE 109 Connected Lever

JFE109 Modes

Auto-Lock
Auto-Lock mode will automatically lock the door.| Press white button above the inside lever. LED will blink green.
Passage
Passage mode allows for free passage (lever is unlocked).| Press white button above the inside lever. LED will blink red twice.

How to unlock the door in Auto-Lock mode

  • Enter valid user code then press,
  • To manually unlock, insert and rotate the key to a vertical position. With the key inserted, turn the lever. Lever will remain unlocked until a key is removed.

How to unlock door in Passage mode

  • Door is always unlocked.

Programming Guide

** Read instructions below before programming your lock!
PROGRAMMING INDICATORS Success:
1 long green blink, 1 long beep Fail: +
2 red blinks, 2 beeps
DEFAULT CODE LOCATIONS
Default Programming Code and user codes are located on labels on the back of the inside assembly and on the front of the English language user guide.
NOTES
** JBE105 Deadbolt and JFE105 Lever can hold up to 10 user codes.
JBE109 Connected Deadbolt and JFE109 Connected Lever can hold up to 30 user codes.
All user codes must be the same length. JBE105/JFE105: Changing user code length will delete all codes not of the chosen length.

Contact Customer Support
888-805-9837
Warranty and FCC/IC Statement alle.co/jseries

ADD USER CODE

DELETE USER CODE

CHANGE PROGRAMMING CODE

ENABLE OR DISABLE VACATION MODE

ENABLE OR DISABLE SOUND

DELETE ALL USER CODES

ENABLE OR DISABLE ONE-TOUCH LOCKING
Deadbo11 modela oI y -ISLAM)

ENABLE OR DISABLE AUTO LOCK

CHANGE USER CODE LENGTH

Z-Wave Functions
ONLY FOR
JBE109 Connected Deadbott
JFE109 Connected Lever
About Z-Wave
This lock is a Security Enabled Z-Wave Product.

  • This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
  • S2 security-enabled controller is required to operate the product. The lock will have limited functionality if included with a non-secure controller.
  • Refer to your home automation system’s documentation for more information.

Add or Remove lock from Z-Wave network

  1. Place your Z-Wave Controller into the “Add” (Inclusion Mode) or “Remove” (Exclusion Mode). Refer to the respective documentation for your home automation system for details.

  2. Remove the battery cover.

  3. Press and hold the enrollment button under the battery cover for 0.5 to 3 seconds as shown. Solid amber LED will be ON.

  4. Release the enrollment button. An LED will flash amber indicating the “Add* or “Remove’ process is in progress. 5. Success is indicated by a green LED blinking and a beep.

**** If a red LED turns on, try repeating steps 1-3.

Z-Wave Plus
For enrollment in some Z-Wave Plus networks, an additional 5-digit code may be required to be entered into the home automation system or panel during Step 4. Enter the 5-digit code shown on the label located on the lock or on the cover of the included installation instructions. Refer to your home automation system’s documentation or app for more information.
JBE109 Deadbolt and JFE109 Lever can be added into a Z-Wave network by scanning the Z-Wave OR Code at the start of this user guide with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network range.

Troubleshooting

Problem| Sound| Lights|

Solution

---|---|---|---
After entering a user code to unlock the lock, the yellow light is flashing and there is a delay before it unlocks.| 4 beeps| 4 yellow flashes| The battery is low and should be replaced.
10 red flashing lights when the outside lock button is pressed.| —-| 10 red flashes| Battery is critical and must be replaced.
Valid user code will not unlock.| 2 beeps| 2 green and red flashes| Vacation Mode is enabled. Disable Vacation Mode.
—-| —-| Must press after entering the user code.
Cannot add user code.| 3 beeps| 3 red flashes| Exceeded the user code limit.
Deadbolt tries to extend twice but doesn’t extend.| 2 beeps| 2 red flashes| Deadbolt jammed, Adjust bolt/ frame alignment.

Factory Default Reset (FDR)

Locate the default code sticker on the lock before attempting the factory default reset (FDR) procedure. Deleted codes CAN NOT be recovered! This will erase all stored information!
Read the full FDR procedure before beginning.

DEADBOLT MODELS (JBE105, JBE109)
** You must re-enter a default access code followed by setting up the lock after restoring to factory default!
1 Determine which deadbolt you have.
Remove battery cover. If there is a small button under the batteries, you have a JBE109 Connected Deadbolt. Follow the labeled steps below. If there is no small button under the batteries, you have a JBE105 Deadbolt. Follow the labeled steps below.
JBE109 Connected Deadbolt
**

  1. Press and hold the enrollment button. The lead will light solid amber.
  2. After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps.
  3. You must enter a valid user code. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops.

JBE105 Deadbolt

  1. Remove one battery.

  2. Press

  3. Replace the battery then wait until power-up is complete, indicated by 1 long green blink and 1 long beep. You must complete the next step within 10 seconds.

  4. Press and hold left for 3 seconds. Successful FDR is indicated by 3 long green blinks and 3 long beeps.

  5. Enter the default access code followed by lock button to set up lock!

LEVER MODELS (JFE105, JFE109)
1 Determine which lever you have.
Remove battery cover. If there is a small button under the batteries, you have a JFE109 Connected Lever. Follow the labeled steps below. If there is no small button under the batteries, you have a JFE105 Lever. Follow the labeled steps below.
JFE109 Connected Lever

  1. Press and hold the enrollment button. The lead will light solid amber.
  2. After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps.

JFE105 Lever

  1. Remove one battery.

  2. Press

  3. Replace the battery then wait until power up is complete, indicated by 1 long green blink and 1 long beep. You must complete the next step within 10 seconds.

  4. Press and hold for 3 seconds. Successful FDR is indicated by 3 long green blinks and 3 long beeps.

©AIlegion 2020
J Series UG Rev. 07/20-e