NOTE
You must press ( ) after entering a user code. Your lock will not recognize a
user code until you press the lock button.
**Proper Use
**
- Use four new AA alkaline batteries for the best performance.
- Do not attempt to disassemble any internal components of the lockset. Doing so will void the limited warranty.
- Do not drop or hit the lockset. Impact may result in permanent damage.
- Do not use pins or sharp objects to press the keypad.
Care and Maintenance
- Remove locks, or do not install locks, prior to painting your door.
- Periodically clean with a mild cleaner and a soft cloth only. Do not use any abrasives or chemical products containing alcohol, benzene, or acids, and avoid using sharp or abrasive objects to clean this lockset.
- Do not allow any water or liquids into the lockset.
- JBE109: You must enter a valid user code after battery replacement. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops.
JBE105 Deadbolt and JBE109 Connected Deadbolt
How to Lock/Unlock
FROM INSIDE | FROM OUTSIDE |
---|
Lock
- Turn thumb turn toward the door edge.
Unlock
- Turn thumb turn away from door edge.
| Lock
Insert key and turn until deadbolt engages.
- Press
Unlock
- Enter valid user code, then press
- To manually unlock, insert a key and turn until deadbolt disengages.
JFE105 Lever
JFE105 Modes
Auto-Lock
Auto-Lock mode will automatically lock the door.| Turn the inside thumb
turn to a horizontal position (pointing left or right) to set it to Auto-
Lock mode.
Passage
Passage mode allows for free passage (lever is unlocked).| Turn the inside
thumb turn to a vertical position (straight up and down) to set it to
Passage mode.
How to unlock the door in Auto-Lock mode
- Enter valid user code then press
- To manually unlock, insert and rotate the key to a vertical position. With the key installed, turn the lever. Lever will remain unlocked until the key is removed.
How to unlock the door in Passage mode
- Door is always unlocked.
JFE 109 Connected Lever
JFE109 Modes
Auto-Lock
Auto-Lock mode will automatically lock the door.| Press white button above
the inside lever. LED will blink green.
Passage
Passage mode allows for free passage (lever is unlocked).| Press white
button above the inside lever. LED will blink red twice.
How to unlock the door in Auto-Lock mode
- Enter valid user code then press,
- To manually unlock, insert and rotate the key to a vertical position. With the key inserted, turn the lever. Lever will remain unlocked until a key is removed.
How to unlock door in Passage mode
- Door is always unlocked.
Programming Guide
** Read instructions below before programming your lock!
PROGRAMMING INDICATORS Success:
1 long green blink, 1 long beep Fail: +
2 red blinks, 2 beeps
DEFAULT CODE LOCATIONS
Default Programming Code and user codes are located on labels on the back of
the inside assembly and on the front of the English language user guide.
NOTES
** JBE105 Deadbolt and JFE105 Lever can hold up to 10 user codes.
JBE109 Connected Deadbolt and JFE109 Connected Lever can hold up to 30
user codes.
All user codes must be the same length. JBE105/JFE105: Changing user
code length will delete all codes not of the chosen length.
Contact Customer Support
888-805-9837
Warranty and FCC/IC Statement alle.co/jseries
ADD USER CODE
DELETE USER CODE
CHANGE PROGRAMMING CODE
ENABLE OR DISABLE VACATION MODE
ENABLE OR DISABLE SOUND
DELETE ALL USER CODES
ENABLE OR DISABLE ONE-TOUCH LOCKING
Deadbo11 modela oI y -ISLAM)
ENABLE OR DISABLE AUTO LOCK
CHANGE USER CODE LENGTH
Z-Wave Functions
ONLY FOR
JBE109 Connected Deadbott
JFE109 Connected Lever
About Z-Wave
This lock is a Security Enabled Z-Wave Product.
- This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
- S2 security-enabled controller is required to operate the product. The lock will have limited functionality if included with a non-secure controller.
- Refer to your home automation system’s documentation for more information.
Add or Remove lock from Z-Wave network
-
Place your Z-Wave Controller into the “Add” (Inclusion Mode) or “Remove” (Exclusion Mode). Refer to the respective documentation for your home automation system for details.
-
Remove the battery cover.
-
Press and hold the enrollment button under the battery cover for 0.5 to 3 seconds as shown. Solid amber LED will be ON.
-
Release the enrollment button. An LED will flash amber indicating the “Add* or “Remove’ process is in progress. 5. Success is indicated by a green LED blinking and a beep.
**** If a red LED turns on, try repeating steps 1-3.
Z-Wave Plus
For enrollment in some Z-Wave Plus networks, an additional 5-digit code may be
required to be entered into the home automation system or panel during Step 4.
Enter the 5-digit code shown on the label located on the lock or on the cover
of the included installation instructions. Refer to your home automation
system’s documentation or app for more information.
JBE109 Deadbolt and JFE109 Lever can be added into a Z-Wave network by
scanning the Z-Wave OR Code at the start of this user guide with a controller
providing SmartStart inclusion. No further action is required and the
SmartStart product will be added automatically within 10 minutes of being
switched on in the network range.
Troubleshooting
Problem| Sound| Lights|
Solution
---|---|---|---
After entering a user code to unlock the lock, the yellow light is flashing
and there is a delay before it unlocks.| 4 beeps| 4 yellow flashes| The
battery is low and should be replaced.
10 red flashing lights when the outside lock button is pressed.| —-| 10 red
flashes| Battery is critical and must be replaced.
Valid user code will not unlock.| 2 beeps| 2 green and red flashes| Vacation
Mode is enabled. Disable Vacation Mode.
—-| —-| Must press after entering the user code.
Cannot add user code.| 3 beeps| 3 red flashes| Exceeded the user code limit.
Deadbolt tries to extend twice but doesn’t extend.| 2 beeps| 2 red flashes|
Deadbolt jammed, Adjust bolt/ frame alignment.
Factory Default Reset (FDR)
Locate the default code sticker on the lock before attempting the
factory default reset (FDR) procedure. Deleted codes CAN NOT be recovered!
This will erase all stored information!
Read the full FDR procedure before beginning.
DEADBOLT MODELS (JBE105, JBE109)
** You must re-enter a default access code followed by setting up the lock
after restoring to factory default!
1 Determine which deadbolt you have.
Remove battery cover. If there is a small button under the batteries, you have
a JBE109 Connected Deadbolt. Follow the labeled steps below. If there is no
small button under the batteries, you have a JBE105 Deadbolt. Follow the
labeled steps below.
JBE109 Connected Deadbolt
**
- Press and hold the enrollment button. The lead will light solid amber.
- After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps.
- You must enter a valid user code. Lock will enter auto-handing routine, locking and unlocking several times. Auto-handing is complete when lock movement stops.
JBE105 Deadbolt
-
Remove one battery.
-
Press
-
Replace the battery then wait until power-up is complete, indicated by 1 long green blink and 1 long beep. You must complete the next step within 10 seconds.
-
Press and hold left for 3 seconds. Successful FDR is indicated by 3 long green blinks and 3 long beeps.
-
Enter the default access code followed by lock button to set up lock!
LEVER MODELS (JFE105, JFE109)
1 Determine which lever you have.
Remove battery cover. If there is a small button under the batteries, you have
a JFE109 Connected Lever. Follow the labeled steps below. If there is no small
button under the batteries, you have a JFE105 Lever. Follow the labeled steps
below.
JFE109 Connected Lever
- Press and hold the enrollment button. The lead will light solid amber.
- After about 8 seconds of holding the button, the amber light will turn off. Release the button. Successful FDR is indicated by 3 long green blinks and 3 long beeps.
JFE105 Lever
-
Remove one battery.
-
Press
-
Replace the battery then wait until power up is complete, indicated by 1 long green blink and 1 long beep. You must complete the next step within 10 seconds.
-
Press and hold for 3 seconds. Successful FDR is indicated by 3 long green blinks and 3 long beeps.
©AIlegion 2020
J Series UG Rev. 07/20-e
G59-KPL0012_01
Read User Manual Online (PDF format)