EMI Delux Heat Ductless Split System Remote Controller User Manual

June 5, 2024
EMI

EMI Delux Heat Ductless Split System Remote Controller

EMI Delux Heat Ductless Split System Remote Controller-
PROD

Thank you very much for purchasing our air conditioner. Please read this owner’s manual carefully before using your air conditioner.

NOTE:

  • Buttons design is based on typical model and might be slightly different from the actual one you purchased,the actual shape shall prevail.
  • All the functions described are accomplished by the unit. If the unit has no this feature, there is no corresponding operation happened when press the relative button on the remote controller.
  • When there are wide differences between Remote controller Illustration and USER’S MANUAL on function description, the description of USER’S MANUAL shall prevail.

Remote Controller Specifications

EMI Delux Heat Ductless Split System
Remote Controller-FIG1

Model RG57A6/BGEFU1
Rated Voltage 3.0V(Dry batteries R03/LR03×2)
Signal Receiving Range 8m
Environment 23OF~140OF

Operation of buttons

  1. ON/OFF Button
    This button turns the air conditioner ON and OFF.

  2. MODE Button
    Press this button to modify the air conditioner mode in a sequence of the following:

  3. FAN Button
    Used to select the fan speed in four steps:
    AUTO LOW MED HIGH
    NOTE: You can not switch the fan speed in AUTO or DRY mode.

  4. SLEEP Button
    Active/Disable sleep function. It can maintain the most comfortable temperature and save energy. This function is available on COOL, HEAT or AUTO mode only .
    NOTE: While the unit is running under SLEEP mode, it would be canceled if MODE, FAN SPEED or ON/OFF button is pressed.

  5. TURBO Button
    Active/Disable Turbo function. Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time(if the indoor unit does not support this function, there is no corresponding operation that happened when pressing this button.)

  6. SELF CLEAN Button
    Active/Disable Self Clean function. Under SELF CLEAN mode, the air conditioner will automatically clean and dry the Evaporator and keep it as fresh for the next operation.

  7. UP Button
    Push this button to increase the indoor temperature setting in 1oF increments to 86oF.
    DOWN Button
    Push this button to decrease the indoor temperature setting in 1oF increments to 62oF.
    NOTE: Temperature control is not available in Fan mode.
    NOTE: Press and hold UP and DOWN buttons together for 3 seconds will alternate the temperature display between the OC & OF scale.

  8. SILENCE/FP Button
    Active/Disable SILENCE function. If pushing, , more than 2 seconds, the FP function will be activated, pushing more than 2 seconds again to disable. When the Silence function is activated, the compressor will operate at low frequency and the indoor unit will bring faint breeze, which will reduce the noise to the lowest level and create a quiet and comfortable room for you. Due to low frequency operation of compressor, it may result in insufficient , , cooling and heating capacity. The FP function can only be activated during the heating operation(only when the setting mode is HEAT). The unit will operate at a setting temperature of 46OF , ,.The display window of indoor unit will display FP . Press the buttons of ON/OFF, SLEEP, FP, MODE,

  9. TIMER ON Button
    Press this button to initiate the auto-on time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the auto-timed setting 60 minutes increments. To cancel the auto-timed program, simply adjust the auto-on time to 0.0.

  10. TIMER OFF Button
    Press this button to initiate the auto-off time sequence. Each press will increase the auto -timed setting in 30 minutes increments. When the setting time displays 10.0, each press will increase the auto-timed setting
    60 minutes increments. To cancel the auto-timed program, simply adjust the auto-off time to 0.0

  11. SWING Button
    Used to stop or start horizontal louver auto swing feature.

  12. DIRECT Button
    Used to change the louver movement and set the desired up/down air flow direction. The louver changes 6O in angle for each press.

  13. FOLLOW ME Button
    Push this button to initiate the Follow Me feature, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. The air conditioner will cancel the Follow Me feature automatically if it does not receive the signal during any 7 minutes interval.

  14. LED Button
    Disable/Active indoor screen Display. When pushing the button, the indoor screen display is cleared, press it again to light the display.

Indicators on LCD

Information are displayed when the remote controller is powered up.

Mode display

  • AUTO
  • COOL
  • DRY
  • HEAT
  • FAN
  • Displayed when data transmitted.
  • Displayed when remote controller is ON.
  • Battery display(low battery detection)
  • Not available for this unit
  • Displayed when TIMER ON time is set.
  • Displayed when TIMER OFF time is set.
  • Show set temperature or room temperature, or time under TIMER setting.
  • Displayed in Sleep Mode operation.
  • Indicated that the air conditioner is operating in Follow me mode
  • Not available for this unit
  • Not available for this unit

Fan speed indication

  • Low speed
  • Medium speed
  • High speed
  • Auto fan speed

Note:
All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation only the relative functional signs are shown on the display window.

How to use the buttons

Auto operation

Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE button to select Auto.
  2. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of 62OF~ 86OF in 1OF increments.
  3. Press the ON/off button to start the air conditioner.

NOTE

  1. In the Auto mode, the air conditioner can logically choose the mode of Cooling, Fan, and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller.
  2. In the Auto mode, you can not switch the fan speed. It has already been automatically controlled.
  3. If the Auto mode is not comfortable for you , the desired mode can be selected manually.

Cooling /Heating/Fan operation

Ensure the unit is plugged in and power is available.

  1. Press the MODE button to select COOL, HEAT(cooling & heating models only) or FAN mode.
  2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 62OF~ 86OF in 1OF increments.
  3. Press the FAN button to select the fan speed in four steps- Auto, Low, Med, or High.
  4. Press the ON/OFF button to start the air conditioner.

NOTE
In the FAN mode, the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either. In this case, only step 1, 3 and 4 may be performed.

Dehumidifying operation

Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing.

  1. Press the MODE button to select DRY mode.
  2. Press the UP/DOWN buttons to set the desired temperature. The temperature can be set within a range of 62OF~ 86OF in 1OF increments.
  3. Press the ON/OFF button to start the air conditioner.

NOTE
In the Dehumidifying mode, you can not switch the fan speed. It has already been automatically controlled.

TIMER OFF
(Auto-off Operation)
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time.
Example:
To stop the air conditioner in 10 hours.

  1. Press the TIMER OFF button, the last setting of stopping operation time and the signal “H” will show on the display area.
  2. Press the TIMER OFF button to display “10H ” on the TIMER OFF display of the remote controller.
  3. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER OFF” indicator remains on and this function is activated.

COMBINED TIMER
(Setting both ON and OFF timers simultaneously) TIMER OFF → TIMER ON (On → Stop → Start operation) This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home.
Example:
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.

  1. Press the TIMER OFF button.
  2. Press the TIMER OFF button again to display 2.0H on the TIMER OFF display.
  3. Press the TIMER ON button.
  4. Press the TIMER ON button again to display 10H on the TIMER ON display .
  5. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER ON OFF” indicator remains on and this function is activated.

TIMER ON → TIMER OFF
(Off → Start → Stop operation)
This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house.
Example:
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.

  1. Press the TIMER ON button.
  2. Press the TIMER ON button again to display 2.0H on the TIMER ON display.
  3. Press the TIMER OFF button.
  4. Press the TIMER OFF button again to display 5.0H on the TIMER OFF display .
  5. Wait for 3 seconds and the digital display area will show the temperature again. The “TIMER ON & TIMER OFF” indicator remains on and this function is activated.

Handling the remote controller

Location of the remote controller.

  • Use the remote controller within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.

CAUTION

  • The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit.
  • Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat.
  • If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver.
  • If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer.
  • Do not drop the remote controller. Handle with care. Do not place heavy objects on the remote controller, or step on it.

Using the remote controller holder(optional)EMI Delux Heat Ductless Split
System Remote Controller-FIG13

  • The remote controller can be attached to a wall or pillar by using a remote controller holder(not supplied, purchased separately).
  • Before installing the remote controller, check that the air conditioner receives the signals properly.
  • Install the remote controller with two screws.
  • For installing or removing the remote controller, move it up or down in the holder.

Replacing batteriesEMI Delux Heat Ductless Split System Remote
Controller-FIG14
The following cases signify exhausted batteries. Replace old batteries with new ones.

  • Receiving beep is not emitted when a signal is transmitted.
  • Indicator fades away.

The remote controller is powered by two dry batteries (R03/LR03X2) housed in the back rear part and protected by a cover.

  1. Remove the cover in the rear part of the remote controller.
  2. Remove the old batteries and insert the new batteries, placing the(+) and (-) ends correctly.
  3. Install the cover back on.

NOTE: When the batteries are removed, the remote controller erases all programming. After inserting new batteries, the remote controller must be reprogrammed.

CAUTION

  • Do not mix old and new batteries or batteries of different types.
  • Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months.
  • Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EMI User Manuals

Related Manuals