Safety Instruction
Read this manual completely and master the safety matters related to operation.
| caveat
If the charging gun or charging cable is damaged:
• Do not use, stop using immediately
• Contact the charging operation staff immediately
---|---
| caveat
In case of emergency:
• Press the emergency stop button
• Contact the charging operation staff immediately
• Take action according to the emergency measures of the owner or charging operator
| caveat
If operating after injury, accident, typhoon, accident or disaster, please observe:
• Are there any flames or smoke inside and outside the charger?
• Whether the charger has been soaked in water, whether there are other liquids and traces
• Whether the charger is damaged due to other reasons
If any of the above conditions occur, please stop charging immediately and contact the charging operator
| caveat
Charge gun lock
During the charging process, the charging gun will be locked to the socket of the charging vehicle. It cannot be pulled out before charging is stopped. Strong pulling is prohibited. Strong pulling with more than 1000N may damage the locking mechanism and risk arcing.
| N o t e
Gun insertion and drawing:
• Take the gun carefully and insert the gun, do not drop and bump
• Pull out the gun carefully and put the charging cable and the charging gun back in place
• Only applicable to national standard interface electric
vehicles
Specification
AC Charging Pile Incoming Current (Circuit Breaker )and CABLE specification
N u m b e r| C h a r g e
r Specification(KW)| I n c o m i n g
Current (Circuit Breaker) Type| C a b l e
Specification
---|---|---|---
1| Single phase AC One Gun 3.5| 20A/2P| 3×4mm²
2| Single phase AC One Gun 7| 40A/2P| 3×6mm²
3| Three phase AC One Gun 11| 20A/4P| 5×4mm²
4| Three phase AC One Gun 22| 40A/4P| 5×6mm²
5| Three phase AC One Gun 43| 80A/4P| 5×16mm²
6| Single phase AC Two Gun 3.5+3.5| 40A/2P| 3×6mm²
7| Single phase AC Two Gun 7+7| 80A/2P| 3×16mm²
8| Three phase AC Two Gun 11+11| 40A/4P| 5×6mm²
9| Three phase AC Two Gun 22+22| 80A/4P| 5×16mm²
10| Three phase AC Two Gun 43+43| 160A/4P| 3×35mm²+2×16mm²
Charging process steps
Step 1
Remove the charging gun from the charging pile and connect it tothecar
charging port.
Step 2
After the charging pile is powered on, there is a waiting time of 10
seconds.After 10 seconds, it enters the main charging page. The UI is as
follows。
| Display internal temperature
---|---
| Gun status: no gun inserted (not ready for charging)
| Gun status: plug in the gun (ready for charging)
| The network is not connected
V0Q69| Program Version
G1| 1 gun
Step 3
Move the charging card to an area closer to the card. After successfully
swiping the card, the charging indicator will light up.Wait for the vehicle
communication to complete and start charging.The UI interface is as follows:
| finished charging
---|---
Transaction| Transaction number
Charged Power| KWH
Total Charging Time| Charging time
Report an error
If there is a fault alarm during charging, the fault indicator will alwaysbe
on.
The UI interface is as follows:
| An error occurred
Please refer to common exception handling methods (The error light is always
on when an error occurs)
---|---
Charger failure out of service| Display the error code, you can check the
error code table
Common exception handling
NO .| u nu s u a l phenomenon| p
o ss i b l e reason| S o l u
t i o n
---|---|---|---
1
| Defective power light| The power
connected
| cord| is| not| Check the power line again by
installer
| the
The light cable is not
connected
| Check the lamp line again by
installer
| the
Open trip| Reset MCB
2| The fault light is
always on.
| Emergency stop switch is
pressed
| Reset the emergency stop button
turning it clockwise
| by
3| No response when swiping| The charging card is not near the swiping
position| Remove the card first, and then close to the swipe area again, do
not move the
card up, down, left, or right
Magnetic card failure or damage| Please contact the customer service center to
replace the card (man-made damage requires paid replacement card)
4| Charging failed| The charging gun is not plugged in| Reconnect the charging
gun to ensure that the gun head is in place; check whether there is an error
light on the charging pile; check whether the buttons on the upper part of the
charging gun are in a natural state; try to restart the charging pile after
power off.
| | Vehicle itself| Go to the 4S shop to investigate the
vehicle’s own problems.
---|---|---|---
error code| Error alarm information| solution
---|---|---
0X4| Memory error shutdown| Power off and restart, if the fault cannot be
recovered, please contact the operator or equipment manufacturer customer
service
0X5| Screen communication timeout and shutdown| Power off and restart, if the
fault cannot be recovered, please contact the operator or equipment
manufacturer customer service
0X6| Leakage shutdown| Please check the charging pile, if in the normal range,
contact the operator or equipment manufacturer customer service
0X7| Main board temperature shutdown| Please check the internal temperature of
the charging pile, if it is within the normal range, contact the operator or
equipment manufacturer customer service
0X8| Overtime shutdown in the background| Please check the charging pile and
network, if in the normal range, contact the operator or equipment
manufacturer customer service
0X9| Charging timeout 99h59m59 timeout| Power off and restart, if the fault
cannot be recovered, please contact the operator or equipment manufacturer
customer service
0XA| Door switch| Please check whether the rear door of the charging pile is
closed, if in the normal range, contact the operator or equipment manufacturer
customer service.
0X20| Emergency stop| When the emergency stop is pressed, turn the emergency
stop switch to the right to recover. 18 If the emergency stop is restored, it
will report the fault and contact the operator or equipment manufacturer
customer service.
0X21| Meter timeout| Power off and restart, if the fault cannot be recovered,
please contact the operator or equipment manufacturer customer service
0X22| CP communication| Please check whether the on-board charger is faulty.
If the on-board charger is in the normal range, contact the operator or
equipment manufacturer’s customer service.
0X23| Grid fluctuation| If the AC voltage is lower or higher than 230V
±10% (or 15%), check the input voltage range, and contact the operator or equipment manufacturer customer service if it is within the normal range.
0X24| Relay failure| Power off and restart. If the fault cannot be
| | recovered, please contact the operator or the
equipment manufacturer’s customer service.
---|---|---
0X25| Temperature failure shutdown| Please check the internal temperature of
the charging pile, if it is within the normal range, contact the operator or
equipment manufacturer customer service.
0X26| overcurrent| Check whether the on-board charger is faulty. If the on-
board charger is in the normal range, contact the operator or equipment
manufacturer’s customer service.
0X27| Gun temperature is too high| Please check the internal temperature of
the charging pile, if it is within the normal range, contact the operator or
equipment manufacturer customer service.
0X28| Ground Fault| Please check the ground connection, if in the normal
range, contact the operator or equipment manufacturer customer service.