torqeedo 1268-00 Cruise 3.0 FP Instruction Manual

June 5, 2024
torqeedo

1268-00 Cruise 3.0 FP
Instruction Manual

This installation drawing is an addition to the original operating instructions.
Read operating instructions before wiring.

Power cable connection

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing

| Positive power cable| | Negative charging cable
---|---|---|---
| Negative power cable| | AC power cable
| Positive charging cable

System ground connection

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
1

**In case the charger is permanently installed in the boat, the charger housing or its AC PE and battery minus pole must be connected to the common grounding point.
The AC connection requires specialist knowledge and may only be carried out by qualified personnel.
If necessary, have the planning and installation carried out by a specialist.
NOTE!** To charge the batteries in the boat, a land connection in the boat with a galvanic isolator or isolation transformer is required according to applicable national requirements (e.g. DIN EN ISO 13297, ABYC E-11).

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
2

Data cable connection

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
3Bus system termination resistor

| 8-pin data cable| | 4-pin data cable| | Backbone TorqLink, 8-pin data cable
---|---|---|---|---|---
| 5-pin data cable| | Backbone 5-pin data cable

Bill of material/Legend/Information

Pos. Item number Name Remarks
1 1268-00 Cruise 3.0 FP
H, I, K, Cable set with battery switch See picture for cable length

L, M
2| | Power connector| max. 175 A
e| | Backbone cable 5-pin| 5000 mm
15| 036-00566| GPS sensor with cable| Cable 2450 mm
3| 2106-00| Power 24-3500| Select TorqLink-Battery in throttle menu!
e| | Backbone cable 5-pin| 5000 mm
16| 2304-00| On/Off Switch Power 24-3500| 5000 mm
with cable| Use to switch the Power 24-3500 on/off manually, if not in use the Power 24-3500 switches  off automatically after 24 hours
W| | System ground| min. 25 mm2, not included
4| 1949-00| Throttle Sidemount Sail|
5| | Throttle Display|
22| 000-00858| Gateway|
U| | Gateway Power cable| 1700 mm
b| | Backbone TorqLink cable 8-pin| 5000 mm
d| | Data cable 4-pin| 1500 mm
17| | Emergency switch with cable| 1000 mm
18| | On/Off switch with cable| 2000 mm
13| 000-00876| TorqLink Terminator| Bus termination resistor
a| | T-Cable 8-pin| 900 mm/50 mm,
Do not extend!
4| 1950-00| Throttle Sidemount|
5| | Throttle Display|
22| 000-00858| Gateway|
U| | Gateway Power cable| 1700 mm
b| | Backbone TorqLink cable 8-pin| 5000 mm
d| | Data cable 4-pin| 1500 mm
19| | Kill switch with cable| 1000 mm
20| | Key switch|
g| | Cable for key switch| 1000 mm
6-Pin to 8-pin
13| 000-00876| TorqLink Terminator| Bus termination resistor
a| | T-Cable 8-pin| 900 mm/50 mm,
Do not extend!
4| 1951-00| Throttle Topmount|
22| 000-00858| Gateway|
U| | Gateway Power cable| 1700 mm
b| | Backbone TorqLink cable 8-pin| 5000 mm
17| | Emergency switch with cable| 1000 mm
20| | Key switch|
g| | Cable for key switch| 1000 mm
6-Pin to 8-pin
13| 000-00876| TorqLink Terminator| Bus termination resistor
a| | T-Cable 8-pin| 900 mm/50 mm,
Do not extend!
9| 2206-20; 2206-30;| Charger Power 24-3500| 350 W
2206-40
P| | + DC charge cable| 2600 mm; Do not extend!
Q| | – DC charge cable| 2600 mm; Do not extend!
B+| | + Battery pole|
B-| | – Battery pole|
AC| | AC power cable| 1500 mm
Optional equipment
10| 2210-00| Fast Charger Power 24-3500| 1700 W
P| | + DC charge cable| 2400 mm; Do not extend!
Q| | – DC charge cable| 2400 mm; Do not extend!
B+| | + Battery pole|
B-| | – Battery pole|
AC| | AC power cable| 2000 mm
11| 2207-00| Solar charge controller
Power 24-3500|
P| | + Charge cable| 1000 mm
Q| | – Charge cable| 1000 mm
R| | + Input solar cable| 1000 mm
S| | – Input solar cable| 1000 mm
12| 2211-00| Fast solar charge controller
Power 24-3500|
P| | + Charge cable| 300 mm
P1| | + Charge cable| 2200 mm
Q| | – Charge cable| 2500 mm
21| | Fuse| 100 A/58 V
R| | + Input solar cable| not included
S| | – Input solar cable| not included

Connect the cruise motor and terminator to each end of the backbone.
The TorqLink bus system requires a terminator (terminating resistor) at both ends of the backbone in order to function correctly.
One of the terminators is located in the „Terminator Single“, „Terminator Twin“, „Throttle 1918-00“, „ Throttle 1976-00“ , the other is built into the cruise motor. Therefore,  when installing, make sure that the components „Terminator“ and „Cruise motor“ are each connected to one end of the backbone.
The connection position of the remaining components on the backbone can be freely selected.
Keep the following points in mind when planning:

  • An earthing point is required for your Torqeedo system. Take into account the connection and the cables required for this in your planning. The required cable cross-ections can be found in the section Tools, equipment, and material.
  • First, determine and plan the installation positions of all components.
  • Measure the required length of the TorqLink backbone.
  • Measure the lengths of all required stub lines (cable connection between the component and TorqLink backbone).
  • When planning, please note that TorqLink drop cables must not be extended. If necessary, plan the TorqLink backbone so that the components can be connected through the TorqLink drop cable without an extension. If necessary, extend the TorqLink backbone to connect a component that is far away; you can find corresponding extensions in our accessories catalog.
  • Cables must be fixed every 400 mm, plan attachment material. In places where fastening is not possible, a scuff guard must be fitted.
  • Openly laid cables (e.g. inflatable boat) must be protected with chafing protection and plan sufficient material.
  • When planning, please note not to bundle power cables with data or antenna cables (e.g. radios) for other loads.
  • Observe the minimum bending radius of the cables when planning.
  • If a second earthed onboard power system is available, ensure that both systems use a common earthing point.
  • Live parts must be fitted or installed with protection against accidental contact; the necessary installation space must be taken into account during the planning stage.
  • Always connect batteries as the last component to the system to avoid short circuits and voltage peaks.
  • Do not extend drop cables, extend the backbone if necessary.
  • Protect plugs and contacts against contamination before installing them.
  • Do not pull at the cables.
  • Do not twist cables.
  • Do not install cables in permanently wet areas such as bilges.
  • Install cables free of chafing and not around sharp edges, if necessary, attach chafing protection.
  • Maintain bending limits.
  • Install plug connections free of tension and load.

Observe the minimum bending radius when laying all cables:

Torqeedo data cable 8 x diameter
Torqeedo power cable 8 x diameter
Earth cable see cable manufacturer’s specifications
Other power cables see cable manufacturer’s specifications

Power cable connection

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
5

| Positive power cable| | Positive charging cable| | AC power cable
---|---|---|---|---|---
| Negative power cable| | Negative charging cable

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
6

| Positive power cable| | Positive charging cable| | AC power cable
---|---|---|---|---|---
| Negative power cable| | Negative charging cable

torqeedo 1268 00 Cruise 3 0 FP - Installation Drawing
7

| Positive power cable| | Positive charging cable| | AC power cable
---|---|---|---|---|---
| Negative power cable| | Negative charging cable