INTRODUCTION
Thank you for purchasing this CLARKE Gas Heater.
Before attempting to use this product, please read this manual thoroughly and
follow the instructions carefully. In doing so you will ensure the safety of
yourself and that of others around you, and you can look forward to your
purchase giving you long and satisfactory service.
This manual was written for use in the United Kingdom. Please note that in
some countries there may be differences in the requirements outlined in this
manual and in these cases the local regulations should be consulted by the
user.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt which will be
required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or
tampered with in any way, or not used for the purpose for which it was
intended.
Faulty goods should be returned to their place of purchase, no product can be
returned to us without prior permission.
This guarantee does not effect your statutory rights.
FUNCTION AND OPERATING PARAMETERS
This is gas powered heater. It’s intended use is for drying and the warming of commercial/industrial buildings where adequate ventilation is provided.
- It must be operated as prescribed in the operating manual.
- Is not intended to be used for domestic use or for the heating of habitable areas.
- Is not intended to be used to reach and maintain a certain level of human thermal comfort within an enclosed space in which the heater is situated.
- Is not intended to be used in enclosed areas with restricted ventilation.
- Is not for use in areas with high levels of fluctuating drafts.
- Is not intended for warming animals or live stock.
GENERAL SAFETY PRECAUTIONS
Read, and make sure you fully understand the following precautions and the hazards associated with this type of equipment.
- ONLY use with the voltage specified and ensure the heater is properly earthed.
- Use only the hose and factory preset regulator provided with the heater.
- Only use propane gas, set up for vapour withdrawal.
- Provide adequate ventilation. Before using the heater, provide at least a 1.5 ft.2 (1400 cm2) opening of fresh outside air.
- For indoor use only. Do not use heater outdoors.
- Not to be used for the heating of habitable areas of domestic premises; for use in public buildings, refer to national regulations.
- Do not use the heater in a basement or below ground level. Propane gas is heavier than air. If a leak occurs. propane gas will sink to the lowest possible level.
- Keep the heater area clear and free from combustible materials, gasoline, paint thinner and other flammable vapours and liquids.
- Do not use heater in areas with high dust content. Dust is combustible.
- Do not point the heater at propane tank.
- Keep propane tank(s) below 100oF (37.8oC).
- Check the heater for damage before each use. Do not use a damaged heater.
- Check the hose before each use of the heater. If highly worn or cut, replace with hose specified by the manufacturer before using the heater.
- Locate the heater on a stable and level surface if the heater is hot or operating.
- Not intended for use on finished floors.
- Never block the air inlet (rear) or air outlet (front) of the heater.
- Keep the heater away from strong drafts, water spray, rain or dripping water.
- Do not leave the heater unattended.
- Keep children and animals away from the heater.
- Never move, handle or service a hot, operating or plugged-in heater.
- To prevent injury wear gloves when handling the heater.
- Never attach duct work to front or rear of the heater.
- Do not alter the heater. Keep the heater in its original state.
- Do not use the heater if altered.
- Turn off the propane supply and unplug the heater when not in use.
- Use only original replacement parts. This heater must use design-specific parts. Improper replacement parts could be highly dangerous.
- Do not place torsional stress on any hoses.
MINIMUM CLEARANCES FROM COMBUSTIBLES
Outlet | 6 Ft. (1.83 m) | Top | 6 Ft. (1.83 m) |
---|---|---|---|
Sides | 6 Ft. (1.83 m) | Rear | 2 Ft. (0.61 m) |
RISKS OF CARBON MONOXIDE POISONING
Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide.
- Carbon Monoxide (CO) is toxic.
- Pregnant women, persons with a heart or lung condition, anaemia or under the influence of alcohol, or those at high altitude, are more likely to be effected by Carbon Monoxide.
- CO can build up in a confined space and failure to provide adequate ventilation can be fatal.
The early symptoms of asphyxiation caused by inadequate ventilation are:
- headache
- dizziness
- nausea
- dry mouth or sore throat
Should anyone show these symptoms, they must GET FRESH AIR IMMEDIATELY. Turn
off the heater and have it serviced before using again.
Be sure to follow all warnings in this manual.
WE RECOMMEND THE USE OF A CARBON MONOXIDE DETECTOR
UNPACKING
When unpacking, check the heater for possible shipping damage. Should any damage be apparent, please notify your Clarke dealer immediately. Your heater is fully assembled,- only the electrical and gas supplies need connecting.
ELECTRICAL CONNECTIONS
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply
through an approved BS1363/A plug fitted with a BS1362 13 amp fuse.
If the plug has to be changed because of damage, it must be removed and a
replacement fitted, following the wiring instructions shown below. The old
plug must be discarded safely, as insertion into a power socket could cause an
electrical hazard.
WARNING: WIRES IN THE MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE
FOLLOWING CODE:
GREEN/YELLOW = EARTH, BLUE = NEUTRAL, BROWN = LIVE.
- The BLUE wire must be connected to the terminal which is marked N or coloured black.
- The BROWN wire mus t be connected to the terminal which is marked L or coloured red.
- The YELLOW AND
GREEN wire must be connected to the terminal which is marked E or or coloured green.
We strongly recommend that this machine is connected to the mains supply
through a Residual Current Device (RCD)
If you are not sure, consult a qualified electrician. DO NOT try to do any
repairs.
THEORY OF OPERATION
THE FUEL SYSTEM: The hose/regulator assembly attaches to the propane gas
supply. This provides fuel to the heater.
THE AIR SYSTEM: The motor turns the fan. The fan pushes air into and
around the combustion chamber. This air is heated and provides a stream of
clean, hot air.
THE IGNITION SYSTEM: The piezo ignitor lights the burner.
THE AUTOMATIC CONTROL SYSTEM: Should the flame extinguish for any reason,
the thermocouple will quickly cool, causing the Flame Failure valve to close,
shutting off the gas supply.
Similary, should there be a power failure, the safety shut off valve
(solenoid) will shut off the gas supply.
The machine is also fitted with a thermal overload protection, which will
operate should the unit overheat, shutting off the gas supply to the heater.
PROPANE GAS SUPPLY
WARNING: THE FITTING AND CHANGING OF THE GAS CYLINDERS MUST BE CARRIED OUT IN A FLAME FREE ATMOSPHERE.
- YOU SHOULD ONLY USE PROPANE GAS CYLINDERS AVAILABLE FROM BUILDERS MERCHANTS OR GAS SUPPLIERS.
This range of portable, direct fired gas heaters is designed to give safe,
efficient and reliable operation, and are for use with propane gas only.
As with all mechanical equipment, optimum performance will only be achieved if
the correct application and servicing procedures are followed.
WARNING: PROPANE GAS CYLINDERS MUST BE USED AND STORED IN ACCORDANCE WITH THE ‘HIGHLY FLAMMABLE LIQUIDS AND LIQUEFIED PETROLEUM GASES REGULATIONS 1972’
In order to reduce the risk of icing up when operating at long periods at
maximum capacity, you should use a larger capacity gas bottle.
Ensure the Propane gas bottle, gas hose and electric cable, are positioned
behind the unit, away from the heat.
IN THE EVENT OF A GAS LEAK
- Put out all smoking materials and other open flames.
- Do NOT operate electric switches or light matches.
- Close all supply valves on gas tank or cylinder.
- Do NOT use your phone. USE a neighbor’s phone or your mobile phone from outside the building or wherever you detected the gas leak to call the fire service.
- Immediately get everyone out of the building or area.
- Do NOT re-enter the building, or area until a trained service person or the fire service advises it is safe to return.
INSTALLATION
WARNING: READ AND UNDERSTAND THE WARNINGS IN THE SAFETY INFORMATION SECTION, PAGE 3. THEY ARE NEEDED TO SAFELY OPERATE THIS HEATER. FOLLOW ALL LOCAL REGULATIONS WHEN USING THIS HEATER.
- TEST ALL GAS PIPING AND CONNECTIONS FOR LEAKS AFTER INSTALLATION OR SERVICING. NEVER USE AN OPEN FLAME TO CHECK FOR A LEAK. APPLY A MIXTURE OF LIQUID SOAP AND WATER TO ALL JOINTS. BUBBLES FORMING SHOW A LEAK. CORRECT ALL LEAKS AT ONCE.
-
Provide a propane supply system (see Propane Gas Supply).
-
Connect POL (Prest-o-Lite) fitting on hose/regulator assembly to the propane tank(s).
- Turn POL fitting anti-clockwise into the threads on the tank.
Tighten firmly using a wrench.
IMPORTANT: Position the regulator so that the hose leaving the regulator is in a horizontal position. This places the regulator vent in the proper position to protect it from the weather.
- Turn POL fitting anti-clockwise into the threads on the tank.
-
Connect the hose to the valve inlet connector. Tighten firmly using a wrench.
IMPORTANT: Use extra hose or piping if needed between hose/regulator assembly and propane tank. You must use the regulator supplied with heater. -
Open the propane supply valve on the propane tank(s) slowly.
NOTE : If the supply valve is not opened slowly, the check valve on the propane tank will activate and stop gas flow. If this happens, close the propane supply valve and open again slowly. -
Check all connections for leaks. Apply a mixture of liquid soap and water to all gas joints. Bubbles forming show a leak that must be corrected.
-
Close the propane supply valve.
VENTILATION
WARNING: PROVIDE AT LEAST A 1.5 FT2 (1400 CM2) OPENING OF FRESH, OUTSIDE AIR WHILE RUNNING HEATER. IF PROPER FRESH, OUTSIDE AIR VENTILATION IS NOT PROVIDED, CARBON MONOXIDE POISONING CAN OCCUR. PROVIDE PROPER FRESH, OUTSIDE AIR VENTILATION BEFORE RUNNING HEATER.
STARTING PROCEDURE!
WARNING: BEFORE STARTING THE HEATER, YOU MUST ENSURE THAT THE MINIMUM VENTILATION REQUIREMENTS ARE OBSERVED TO AVOID THE RISK OF CARBON MONOXIDE POISONING.
TO START THE HEATER
-
Follow all installation, ventilation, and safety information.
-
Locate the heater on stable and level surface.
- Make sure strong drafts do not blow into the front or rear of the heater.
-
Plug the heater into a suitable 230V mains socket.
-
Set the on/off switch to the on position.
- The motor will start, the fan will turn, forcing air from the front of the heater.
-
Open the propane supply valve on the propane tank(s) slowly.
NOTE: If not opened slowly, the excess-flow check valve on the propane tank will stop the gas flow. If this happens, close the propane supply valve and open again slowly.
WARNING: MAKE SURE THAT THE MOTOR AND FAN ARE RUNNING BEFORE PUSHING IN AUTOMATIC CONTROL VALVE BUTTON. FLAMES COULD FLASH OUTSIDE HEATER IF THE MOTOR AND FAN ARE NOT RUNNING. -
Push in and hold the automatic control valve button.
-
Push the piezo ignitor button.
-
You may need to push the piezo ignitor button 3-8 times until the burner lights.
-
When the burner lights, keep the automatic control valve button pushed in.
-
Release the automatic control valve button after 15 seconds.
NOTE: If the heater fails to ignite, the hose may have air in it. If so, keep the automatic control valve button pressed and wait 20 seconds. Release the automatic control valve button and wait 20 seconds for unburned fuel to exit the heater, repeat steps 6-8.
STOPPING PROCEDURE
TO STOP THE HEATER
- Tightly close propane supply valve on propane tank(s).
- The heater will burn away gas left in supply hose.
- Allow the heater to cool down for 5 minutes, then switch off the heater.
- Unplug the heater.
TO RESTART THE HEATER
- Wait five minutes after stopping the heater.
- Repeat steps under ‘To Start The Heater’.
STORAGE
CAUTION: DISCONNECT THE HEATER FROM PROPANE SUPPLY TANK(S)
- Store propane tank(s) in safe manner.
- Follow all local regulations.
- Always store propane tanks outdoors.
- Place plastic cover caps over any brass fittings, the connector and hose/regulator assembly.
- Store in a dry, clean and safe place.
- When taking heater out of storage, always check inside of heater. Insects and small animals may place foreign objects in heater.
MAINTENANCE
WARNING: NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, CONNECTED TO THE PROPANE SUPPLY, OPERATING OR HOT. SEVERE BURNS OR ELECTRIC SHOCK MAY OCCUR.
- KEEP THE HEATER CLEAR AND FREE FROM ANY COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPOURS AND LIQUIDS.
- DO NOT BLOCK THE FLOW OF COMBUSTION OR VENTILATION AIR.
- Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth.
- Inspect the heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.
- Inspect the hose/regulator assembly before each use. If the hose is highly worn or cut, replace with a hose specified by the manufacturer.
- Have heater inspected yearly by a qualified service agency.
- Keep the inside of the heater free from combustible and foreign objects.
TROUBLESHOOTING
WARNING: NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, CONNECTED TO PROPANE SUPPLY, OPERATING OR HOT. SEVERE BURNS AND ELECTRICAL SHOCK CAN OCCUR.
OBSERVED FAULT | POSSIBLE CAUSE | REMEDY |
---|---|---|
Fan does not | No electrical power to the | Check voltage to |
turn when | heater | electrical outlet. If voltage |
heater is | is good, check heater | |
plugged in | power cable for breaks | |
Structural damage | Return to your dealer for | |
repair. | ||
Defective motor | Return to your dealer for | |
repair. | ||
Heater will not ignite | User did not follow installation or operation | |
instructions properly | Repeat installation and operation instructions. See |
Installation and Starting, page 8+9
| No spark at ignitor. If no spark seen, the fault may be:| A) Check ignitor
wire. Tighten or reattach loose ignitor wire.
| A) Loose or disconnected ignitor wire
B) Wrong spark gap
| B) Set gap between ignitor electrode and target plate to 0.17″ (0.43
cm)
| C) Piezo ignitor loose
D) Bad ignitor electrode
| C) Tighten nut holding piezo ignitor to base of heater
| | D) Replace ignitor electrode.
| | If you see a spark at the ignitor have the heater serviced by a
qualified service person.
SPECIFICATIONS
ENVIRONMENTAL PROTECTION
These products contain valuable raw materials. Do not dispose of this product
with general household waste. All tools, accessories and packaging should be
sorted and disposed off appropriately by taking to a recycling centre.
PARTS DIAGRAM
1 | Grill Assembly | GFLDEV201 | 14 | Middle Cylinder Assembly | GFLDEV214 |
---|---|---|---|---|---|
2 | Motor Mounting Bracket | GFLDEV202 | 15 | Power Cord | GFLDEV215 |
3 | Motor Assembly | GFLDEV203 | 16 | On/off Switch | GFLDEV216 |
4 | Screw,45# 1/4″-28*1/3 | GFLDEV204 | 17 | Hose/regulator Assembly | GFLDEV217 |
5 | Fan | GFLDEV205 | 18 | Piezo Ignitor | GFLDEV218 |
6 | Thermal Switch Kit | GFLDEV206 | 19 | Palnut Fastner | GFLDEV219 |
7 | Burner Tube Part 2 | GFLDEV207 | 20 | Control Box Assembly | GFLDEV220 |
8 | Burner Tube Part 1 | GFLDEV208 | 21 | Control Valve Assembly | GFLDEV221 |
9 | Electrode Ignitor | GFLDEV209 | 22 | Magnet Valve | GFLDEV222 |
10 | Handle | GFLDEV210 | 23 | Regulator Connector | GFLDEV223 |
11 | Handle Clip | GFLDEV211 | 24 | Magnet Valve Assembly | GFLDEV224 |
12 | Outer Cylinder | GFLDEV212 | 25 | Air Tube | GFLDEV225 |
13 | Front Guard | GFLDEV213 | 26 | Thermocouple | GFLDEV226 |
Read User Manual Online (PDF format)