Shenzhen Yago Technology YY-103 Series Intelligent ph Meter User Manual
- June 3, 2024
- Shenzhen Yago Technology
Table of Contents
YY-103 Series Intelligent ph Meter
User Manual
YY-103 Series Intelligent ph Meter
PARAMETER
Model|
---|---
PH| Range: 0.00-14.00 pH
Resolution: 0.01 pH
Accuracy: 10.1pH
TEMP| Range: 0.1•C-60.0•C; 32.1•F-140.0•F
Resolution: 0.1•C;0.1•F
Accuracy: 10.5•C
PH Calibration| 6.66 / 4.00 / 9.18 or 7.00 1 4.00 / 10.01 ( Optional two sets
of calibration modes)
Calibration records can be viewed
Electrode Replaceable| Puncture
electrode| Flat
electrode| Online It
electrode| Bulb
electrode| corvine
Bulb Electrode
3.3M KCL Electrode Storage Solution
Temp. ATC| 0.1•C-60.0•C
Environment| 0.1•C-801C RH: max 90%
Waterproof| IP67
Battery| 4 • 1.5V ( LR44 ); low battery indicator
Bluetooth| Mobile Bluetooth 5.2 version
Backlights| with backlights • support mobile control
Data| Save as an Excel sheet
Support printing
Data storage| Can store the latest 1000 records of data
Standby time| Around 50 days ( turn on Bluetooth ) 2 years ( turn off
Bluetooth )
FUNCTIONS OF DIFFERENT MODELS
Model/Electrode | USE |
---|
YY-1030
Puncture electrode| Solid and semi-solid sample testing such as cheese, meat,
fruit, flour products, soil, and solid culture medium and routine aqueous
solution testing
YY-1031/YY-1031L
Flat electrode| Flat sample tests such as skin, paper, cloth, and leather,
micro solution test, routine aqueous solution test
YY-1032/YY-1032L
Bulb electrode| Routine aqueous solution testing, such as hydroponics,
aquaculture, swimming pools, spas, water treatment, and beverages, etc.
YY-1030 The puncture electrode is mainly used to measure the solid or semi-
solid medium containing water.
When inserting the electrode, please pay attention to evenly applying force to
prevent the electrode from being damaged. If the sample to be tested is
relatively solid (such as meat and fruit), you should use a tapered knife to
pierce a small hole before inserting the electrode.
When testing food (such as sushi, cheese, meat, fruit, etc.), always use
samples for testing, and the test samples are not edible.
YY-1031/YY-1031L The flat electrode is mainly used to measure flat samples.
When testing the skin: there should be no sweat or dirt on the skin surface,
but it should not be excessively cleaned (before testing, please do not use
cleansing products) to avoid affecting the measurement results. Moisten the
skin slightly with distilled water, press the flat electrode slightly on the
skin, and read after the measurement result is stable.
When testing paper, cloth, or leather: add 1-2 drops of distilled water to
slightly wet and then test it directly.
YY-1032/YY-10321 The bulb electrode is mainly used for routine aqueous
solution testing.
The bulb glass membrane adopts a low-impedance glass-sensitive membrane which
is easy to respond quickly to H+ in the solution.
OPERATION
App download
| |
---|---|---
https://apps.apple.com/us/app/yinmik/id1590106540|
http://www.zghuiquan.com/app/yinmik.apk
- 105 system: Open the APP store that comes with your ‘Phone, search for Y1NMIK and download it;or scan the OR code with Google Chrome to download the APP.
- Android system: Scan the OR code with Google Chrome to download the APP.
- Notes: 1. When the meter’s connected to the APP,It needs to locate the mobile phone to connect successfully.
2. The APP Is updated frequently. After the update, the old version may not
be connected or used. Just uninstall the old APP and download the new version
and connect the meter to the new version of the APP again.
Bluetooth connection
- Press the ‘ON/OFF button for 3-5 seconds to turn on the Bluetooth of the meter. After the Bluetooth Is turned on, the screen will display the Bluetooth Icon. (Picture 1)
- Turn on the mobile phone location function, otherwise, the connection will fail.
- Turn on the Bluetooth of the mobile phone and search for the model of the meter click connect when the model of the meter appears.
- 0pen the ‘YINMIK’ APP, the APP will automatically match the model of the meter. when the APP page displays the meter model, Indicating that the meter is successfully connected to the APP.(Picture 2)
APP FUNCTION
- Click can switch between Chinese and English
- Display all test results ( pH °Crf ) on the app I Interface
| Backlight ON
---|---
| Backlight Off
| Battery power
Hold reading
The hold is on H on the screen
Save Reading
Manually save, Press to save.
Press to view the measurement record.
Calibration
record
Press can view calibration records.
Data viewing/sharing
Press to view records. Press to share the file.
If connect to the printer, the testing records can be printed.
Autosave time can be set inl
Auto Saved time interval can be set between 30-9999 seconds.
Auto Save: | Auto Save OFF | |
---|---|---|
interval ( s ) | ||
Auto Save: | Auto Save ON | |
--- | --- | --- |
Interval ( s ) |
Set PH Max or Min limit values
Set the maximum or minimum pH limit according to user requirements the test
result is out of range, the value will be displayed in red.
PH CALIBRATION
-
Two calibration modes: 6.86/4.00/9.18 (Asian standard) and 7.00/4.00/10.01 (EU standard) can be chosen in Dissolve the chosen powders In different cups with 250m1 distilled water.
-
Put the electrode into 6.86 solutions, Walt for the value stabilize, press ICALI for 5 seconds and the screen will display “CAL”, release the button and wait for 6.86 to flash 3 times to complete 6.86 calibrations.
-
Put the electrode into 4.00solution, Wait for the value to stabilize, and press ICALI for 5 seconds and the screen will display “CAL”, release the button and W811101’4.00 to flash 3 times to complete 4.00 calibration.
-
Pultheelectrode into 9.18 solution, Wait for Tor the value to stabilize, press ICALI for 5 seconds, and the screen will display ‘CAL”, release the button and wait for 9.18 to flash 3 times to complete 9.18 calibration.
NOTICE
- 1t Is factory calibrated and can be used directly.
- when finished, clean the electrode with pure water.
- Gently stir several times to make sure there are no air bubbles around the electrode.
- Do not disassemble the instrument without permission to avoid damage.
- During the test, it is normal for the probe to generate resistance when it encounters air and the value jumps.
- Be careful not to impact or collide with the electrode bulb, otherwise, It will cause rupture. If damaged, the electrode needs to be replaced.
QUALITY ASSURANCE
We warrant that this Instrument is free from defects in material and
workmanship, and warrant that any product that is inoperable due to poor
manufacturing will be repaired or replaced by our company free of charge. This
warranty does not cover damage caused by: Improper use, normal wear, and tear,
accidental damage, etc.
Note that the product warranty period refers to the time when the user
purchases the product to provide free services, not the service life of the
Instrument or electrode. To apply for a warranty or seek other assistance,
please send an email tojonedlszyago.com.
This device complies with part IS of the FCC Rules. Operation is subject to
the following two conditions: (I) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply nth the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in Ina residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used In
accordance with the instructions. may cause harmful interference to radio
communications. However, there Is noguaranteetnat Interference will not
occur**. particular Installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Mcrae set separation between the equipment and receiver.
- Connect the equipment To an outlet on a circuit different from that to which the receiver is connected.
- Consult theater or an experienced radio/TV technician for help. The device has been evaluated to meet general Rgexposure retirement. The device can be used in porta exposure conditions withoufrlicrtaWra `e WI and ows