Safety
Do not allow insulation material to rest against the sides or top of the Ventilation unit when installed
Read through these instructions fully before commencing installation.
Locate the IXL Ventflo in accordance with the requirements of the current
Australian/New Zealand Wiring Rules AS/NZS 3000 relating to damp situations,
or according to applicable Wiring Rules for installations outside of Australia
and New Zealand.
In some installations this may mean that no part of the appliance may be
located directly above any part of a bath or shower recess or enclosure. For
unenclosed showers refer to Wiring Rules conditions. This unit is fitted with
a cord and plug, however, any interconnecting wiring and switches used or use
of another cord and plug must be fitted by a licensed electrician.
Switches and other controls must not be located where they can be touched by a
person in the bath or shower.
Warning:
· Pull out the power plug before cleaning or maintenance. · Do not use this
appliance for functions other than those described in this user guide. · After
removing the appliance from its packaging, ensure that it is complete and
undamaged. · If in doubt contact a qualified electrician or IXL Home. Do not
leave packaging within the reach
of children or infirm persons. · This appliance is not intended for use by
persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning the use of the
appliance by a person responsible for their safety. · Young children should be
supervised to ensure they do not play with the appliance. · Do not operate the
appliance in the presence of inflammable vapours (alcohol, insecticides,
petrol, etc.) · Do not sit or place objects on or in the appliance. · The
supply cord cannot be replaced. If the cord is damaged the appliance should be
scrapped. · Do not operate this appliance without the plastic surround in
position. · This appliance must be mounted with the lowest point at least 2.1
metres from the floor. · Ensure that the fan is switched off from supply mains
before removing the grille/guard.
Caution:
· Do not make modifications of any kind to this appliance. · Do not expose
this appliance to the weather (rain, sun, etc.) · Do not immerse the appliance
or any parts of it in water or other liquids. Refer to the relevant
instructions to clean the appliance (refer to Cleaning). · If the appliance
does not function correctly or develops a fault, contact IXL Home immediately.
· Should the appliance be dropped or suffer a heavy blow, have it checked by
an authorised
service agent for IXL products. · The electrical system to which the appliance
is connected must conform to applicable
standards. · The electrical power supply/socket to which the appliance is to
be connected must be able to
provide the maximum electrical power required by the appliance. If it can’t do
this, contact a qualified electrician to make the necessary modifications. ·
Switch off the appliance at the installation’s main switch: a) if the
appliance does not function correctly; b) before cleaning the outside of the
appliance; c) if the appliance is not going to be used for any length of time.
· The room must have an adequate source of replacement air for this appliance
to function effectively. Moreover, if there is any non-sealed combustion based
appliance such as a water/gas heater, gas stove etc. in the same room, air
replacement must be sufficient for all appliances to work effectively
together. · Keep the appliance’s inlet grille/guard free from dust to ensure
optimum air flow.
Clearances
All appliances must be mounted so that the lowest point is at least 2.1m above
the floor.
The IXL Eco Ventflo is designed to fit a ceiling cavity with a minimum height
of 155mm (10332) & 200mm (10333) when installed in a well ventilated roof
cavity. Where ventilation is restricted, these heights should be increased by
a minimum of 60mm. This will allow for the back draught shutters to open fully
when the unit is in operation.
Additionally, a minimum of 40mm clearance is required between the sides of the
fan and any adjoining parts of the roof structure, such as walls, joists or
insulation batts.
Figure 1 measurement A:
Model 10332 (Eco Ventflo 200) 155mm min.
where there is good ventilation to the sides
of the unit. 215mm min. where ventilation to
the sides of the unit is restricted.
A
Model 10333 (Eco Ventflo 250) 200mm min.
where there is good ventilation to the sides
of the unit. 260mm min. where ventilation to
the sides of the unit is restricted.
SHUTTERS
B
Figure 1 measurement B:
40mm min. clearance on all sides to allow clips to fully rotate outwards.
Fig. 1: Minimum clearances for installation.
Flat Roof Installations
When installing into a flat roof with insufficient clearance, or where ceiling
cavity ventilation is restricted, an external venting duct must be installed.
Use Fig. 2 as a guide to minimum external outlet requirements.
IMPORTANT: Do not attach the duct to the body of the fan. Allow for 10-20mm
minimum gap between the fan and the end of the duct. The duct should have a
diameter of at least 235mm (10332) & 290mm (10333).
Eco Ventflo unit
Fig. 2: Minimum external outlet requirements.
Electrical Requirements
See the wiring diagram (Fig. 3) for supply requirements and maximum loadings
for each model. Fans may be connected to a lighting power circuit if loading
permits. Wiring of the wall switch (not provided) and socket outlet in roof
cavity must be carried out by a registered electrician. The wall switch should
be located in accordance the Wiring Rules AS/NZS 3000. It must not be
installed where it can be reached by a person in the bath or shower.
Ventilation Requirements
For maximum efficiency and fan performance there are a few key points to keep in mind when installing your IXL Eco Ventflo exhaust fan.
Sufficient air inlet into room
Steam will only be removed if there is sufficient flow of air through the
room. Ensure generous inlets exist through windows, vents or under the door.
Air flow path from inlet to fan should ideally pass over the steam sources.
(See Fig 4.)
Adequate ventilation in roof cavity
It is essential that there is adequate space within the roof cavity so that
exhaust air from the fan can dissipate. Where space is restricted, use Fig. 1
as a guide to minimum requirements for adequate ventilation.
The roof cavity itself should be well ventilated to outside so that moist air
can be removed. Local building codes may require flueing to outside through
roof as per Fig. 2 for flat roof installation.
Where ventilation space is restricted
This product is not recommended for installation between floors of multi-
storey dwellings, or where space within the roof cavity is severely restricted
and a flue as per Fig. 2 cannot be fitted. IXL has other Ventilation products
available that are particularly suited to installations between floors or
where space is restricted.
For further details and advice on ventilation products and tips, contact our
retail partners or IXL Home customer service team.
Shown installed between shower and bath
Shown installed above shower
Fig. 4: Ideal placement of Eco Ventflo. Sufficient air inlets into room are
required.
Fig. 3: Wiring diagram.
Installation Instructions and User Guide – IXL Eco Ventflo
Model: 10332 IXL Eco Ventflo Ceiling Exhaust Fan with Draught Shutters 200,
Model: 10333 IXL Eco Ventflo Ceiling Exhaust Fan with Draught Shutters 250,
(Electric Rating: 230-240 V. 50Hz)
Installation
Important considerations before installing · Remove protective packaging from
the product before installation. · Joists, beams and rafters shall not be cut
or notched to install the appliance. · For the exhaust fan to work
efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn
under the door or through a slightly open window. If the room is airtight the
fan will function poorly. · This product is designed for installation in flat
ceiling only. Do not mount it on a sloping ceiling or vertical wall.
1. Locating the unit Before commencing any cutting, check in the ceiling
space that there are no obstructions such as ceiling joists and that there is
sufficient clearance for the housing. Check that the electrical wiring can be
routed from the wall switches to the mounting location.
2. Prepare the ceiling Using the template provided, mark the ceiling with a
pencil outline and cut out the required hole (10332 needs 240mm dia. & 10333
needs 295mm dia. hole).
3. Remove the grille (simply turn anti-clockwise to unlock), see (Fig.5) 4.
Plug the fan into the power point.
a. Before inserting the fan into the opening, push the three bar clamps all
the way out to hold the fan in the ceiling. Push the fan into the ceiling
opening and secure the exhaust fan by tightening the screws securely (Fig.6)
b. For thicker ceilings (13mm or more), remove the three bar clamps. Use wood
screws (not supplied) to secure the fan to the ceiling. Locate screws in the 3
holes in the outer lip of the fan frame.
5. Using a screwdriver (or a battery driver with a low torque setting)
partially tighten the screws. This will move the mounting clips into the open
position and hold the unit to the ceiling.
6. Rotate the unit so that the grille direction lines on the body are aligned
with the walls. These lines show the orientation of the fascia grille when
installed.
7. Do not over tighten the screws as this can damage plasterboard. 8. Fit
grille onto unit. Once fitted the grille can be adjusted to better align with
the walls.
Push in the 3 bar clamps
UNLOCK LOCK
Fig. 5
Tighten screw
Fig. 6
Use
1. Turn the power switch on/off to make sure the unit runs. 2. Running the
fan can exhaust steam and odours quickly and efficiently.
Note: Shut off power urgently when any abnormalities occur in operation. Then
call a licensed electrician or IXL service person for inspection and necessary
service work. Do not insert fingers or thin bars into the grille when the unit
is operating. This could cause harm to yourself and the appliance. The unit
must not be installed in a place that suffers from severe water leakage. 3.
When the unit is switched off, the draught shutters when closing, will make a
slight sound. This is normal operation.
Cleaning
1. Shut power off before cleaning or maintenance. 2. Remove grille and wipe
it with care using a damp soft cloth with a mild detergent if necessary.
Ensure the motor or other electrical parts can’t touch the water. 3. The
grille can be cleaned in a dishwasher on low heat setting ~45°C and only wash
on the
top shelf. 4. Replace the grille from the dishwasher after it is thoroughly
dry.
Warranty
Two Year Replacement Warranty This Warranty against defects for your newly
purchased IXL product is proudly prepared by IXL Home Pty Ltd of 1K Marine
Parade, Abbotsford, VIC 3067, phone 1300 727 421. 1. IXL Home Ventilation
products come with guarantees that do not exclude the following consumer
entitlements under the Australian Consumer Law: a. replacement or refund for a
major failure and compensation for any other reasonably foreseeable loss or
damage; and b. to have the goods replaced if goods fail to be of acceptable
quality and the failure does not amount to a major failure. 2. IXL Home
warrants that your product and related supply will be free from defects in
materials and workmanship during the warranty term. Your warranty term is two
years commencing from the date of purchase. 3. Subject to Point 1, IXL Home
will during the warranty term provide a replacement of an equivalent current
model where the balance of the warranty period from the original date of
purchase will take effect. 4. To the fullest extent permitted by law and
subject always to Point 1, IXL Home will not be liable for: a. any loss or
damage arising from loss of use, loss of profits or revenue; or b. for any
indirect or consequential loss or damage resulting from any breach of this
warranty
against defects.
5. Defective IXL Home products may be replaced by a refurbished product of
the same type.
Limitations to Your IXL Warranty 6. Subject to Point 1, this Warranty:
a. will only be provided to the original purchaser where the original purchase
was made from a IXL Home Authorised Dealer or Reseller and proof of such
purchase can be presented at the time of service;
b. only applies to IXL Home products purchased in Australia and New Zealand
from an IXL Home Authorised Dealer or Reseller;
c. will not apply where the defect in or failure of the product is
attributable to misuse, abuse, accident or non-observation of the
manufacturer’s instructions. This product must be used in accordance with the
manufacturer’s instructions;
d. will not cover faults due to normal wear and tear with reasonable use nor
consumable components such as globes, filters, glass items etc;
e. will not cover any damages or problems caused to this product by natural
forces eg. storm, fire, flood, and earthquake; or by intrusion or accumulation
(or both) of foreign matters eg. dust, soil, and moisture. IXL Home recommends
that you take out appropriate insurances to protect your product to this end;
f. will not apply if this product is installed in a mobile dwelling eg.
caravan or boat; g. will not apply if this product is removed from the
location where it was first installed; h. covers use of this product for
domestic use only; i. will not be restarted or extended upon replacement of
the product or a part. How to Make a Claim Under Your IXL Warranty 7. To make
a claim under this Warranty you will need to: a. contact IXL Home customer
service department on 1300 727 421 or service@ixl.com.au
to provide details and register your claim enabling a IXL Home assessment; b.
submit proof of purchase with your claim eg. tax invoice or purchase receipt;
c. where a property has been constructed by a builder/developer and it is
fitted with IXL
products, please submit proof of purchase by way of the certificate of
occupancy, with your claim. 8. IXL Home will contact you to make arrangements
for a replacement product.
Privacy
The privacy of your personal information has always been important to us. To
learn more about how we collect, keep and use your personal information,
please obtain a copy of our privacy statement by visiting our website at:
www.ixlappliances.com.au or by contacting us via email on orders@ixl.com.au or
by telephone on 1300 727 421.
IXL Home
1K Marine Parade, Abbotsford, Victoria 3067 Australia. Free Call: 1300 727 421
www.ixlappliances.com.au | orders@ixl.com.au New Zealand – Free Call: 0800 727
421 | www.ixlappliances.co.nz | orders@ixl.com.au IXL and Ventflo are
registered trademarks of Alver Pty Ltd in Australia and New Zealand used under
licence by IXL Home Pty Ltd. Made in China