EnVisinLED AM LED Light Fixture Instruction Manual

June 1, 2024
EnVisinLED

EnVisinLED AM LED Light Fixture

Product Information

Specifications:

  • Dimming Functions: 3
  • Optional Brackets : 10
  • Installation Types : Adjustable Fitter Mounting, Direct Mounting, Yoke Mounting, Flood Mounting, Adjustable Fitter Mounting & Direct Mounting

Product Usage Instructions

Installation:

  1. Do not use any electric generator to test the LED light.
  2. Abide by country, regional, and local laws and regulations during installation.
  3. Turn off the power before installation or maintenance.
  4. Ensure proper earth grounding for safety.
  5. Make sure the lighting faces downward vertically after installation.

Notices:

  • Installation personnel must have professional electric knowledge to avoid electrical shock or fire.
  • Wear gloves to avoid injury during installation.
  • If any smoke or spark from the wire occurs, immediately turn off the power and notify the relevant personnel.

Attention:

  1. Check for shipping damage and contact the manufacturer if found.
  2. Read the installation instructions carefully to ensure all accessories are present before installation.

Instructions:

  1. The product has a dimming function with 3 options available.
  2. Choose the appropriate dimming way according to your needs or choose not to use this function.
  3. Select wire connection ways, dimming ways, and installation ways according to your needs and purchase LED fixtures.

Wiring Diagram:

Refer to the lamp label for wire color of DIM+ and DIM-.

Optional Brackets and Installation Instructions:

Different brackets were available for various mounting options. Follow specific instructions for each bracket type.

FAQ

  • Q: What should I do if I encounter issues during installation?
    • A: If you encounter any issues during installation, please refer to the user manual for troubleshooting steps. If problems persist, contact customer support for assistance.

INSTALLATION INSTRUCTIONS

CAUTION:

  1. Do not use any electric generator to test this LED light.
  2. Please abide by related country, regional and local law and regulations when installing this fixture.
  3. Please turn off the power before installation or maintenance.
  4. Proper earth grounding is required to ensure safety.
  5. Make the lighting face downward vertically after installation

Notice:

  1. To avoid the possibility of electrical shock or fire, the installation personnel must have professional electric knowledge.
  2. Please wear gloves to avoid injury before installation.
  3. If any smoke or spark of the wire happens, please turn off the power immediately and notify the relevant personnel.

Attention:

  1. Please check if there is any damage during shipping. If so, please contact the manufacturer timely.
  2. Please read the installation instructions carefully to check whether all the accessories are present.
    After confirmation, Install the fixture according to installation steps.

Instructions:

  1. This product has a dimming function.
  2. 3 dimming functions are available in this LED light.
    • (1). Constant current can be achieved by 0-10VDC or 1-10VDC dimming.
    • (2). PWM signal dimming.
    • (3). Variation of resistance unit dimming (Please choose the appropriate dimming way according to your needs. You can also choose not to use this function).
  3. Choose the wire connection ways, dimming ways and installation ways according to your needs and the led fixture purchased.

Wiring Diagram

EnVisinLED-AM-LED-Light-Fixture-fig \(1\)

EnVisinLED-AM-LED-Light-Fixture-fig \(2\)

Optional Brackets and Installation Instructions
There are 10 optional brackets for this fixture. The following is shoe box fixtures with different brackets.

Installation Instructions with different brackets

ADJUSTABLE FITTER MOUNTING (e=AM)

EnVisinLED-AM-LED-Light-Fixture-fig \(3\)

  • Step 1 : Remove the bracket mounting screws on the fixture and pass the wires through the bracket. (Figure 1)
  • Step 2 : Install the bracket on the fixture. (Figure 2)

DIRECT MOUNTING (e=DM)

  • Step 1 : Remove the bracket mounting screws on the fixture,open the side lid of the bracket and pass the wires through the bracket. (Figure 3)
  • Step 2 : Install the bracket on the fixture, then cover the side lid and tighten it . (Figure 4)

EnVisinLED-AM-LED-Light-Fixture-fig \(4\)

YOKE MOUNTING (e=YM)

  • Step 1 : Remove the bracket mounting screws on the fixture and pass the wires through the bracket. (Figure 5)
  • Step 2 : Install the bracket on the fixture. (Figure 6)

EnVisinLED-AM-LED-Light-Fixture-fig \(4\)

FLOOD MOUNTING (e=FM)

  • Step 1 : First install two big screws. (Figure 7)
  • Step 2 : Install two small screws . (Figure 7)

EnVisinLED-AM-LED-Light-Fixture-fig \(6\)

ADJUSTABLE FITTER MOUNTING & DIRECT MOUNTING (e=A&D)

  • Step 1 : Remove the bracket mounting screws on the fixture,open the side lid of the bracket and run the wires through the bracket. (Figure 8)
  • Step 2 : Install the bracket on the fixture, then cover the side lid and tighten it . (Figure 9)

EnVisinLED-AM-LED-Light-Fixture-fig \(7\)

Installation of LED light

ADJUSTABLE FITTER MOUNTING (e=AM)

  • Step 1 : Connect the wire correctly and put the wires into pole. Then fasten the locking bolts between slip fitter and the pole.(Figure 10)
  • Step 2 : Loosen the fixing bolts and adjusting bolts, and align the fixture to the required angle. Tighten adjusting bolts and fixing bolts after the angle is confirmed.(Figure 11)
    • Notice: Adjustable angle is 0~+/-90°(Figure 10)

EnVisinLED-AM-LED-Light-Fixture-fig \(8\)

DIRECT MOUNTING (e=DM)

EnVisinLED-AM-LED-Light-Fixture-fig \(9\)

  • Step 1 :Fix the DM bracket to the square pole with the bolt, open the side lid of the DM bracket, pull the wire into the junction box, and connect the wires correctly (Figure 12)
  • Step 2 : Put the connected wires into the junction box, then cover the junction box (Figure 13)
  • Notice : The adjustable angle range is 0-35°(Figure 12) Same as round pole installation, please remember to remove the silicon plate when installing the fixture in the round pole (Figure 14)

YOKE MOUNTING (e=YM)

EnVisinLED-AM-LED-Light-Fixture-fig \(10\)

  • Step 1 : Drill holes on the wall as shown in( Figure 15)
  • Step 2: Knock the expansion bolts into the wall.(Figure 16)
  • Step 3: Connect the fixture to the bracket and tighten the screws; connect the wires properly and put them into a junction box.(Figure 17)
  • Notice: Adjustable angle is 0-90°(Figure 17)

FLOOD MOUNTING (e=FM)

EnVisinLED-AM-LED-Light-Fixture-fig \(11\)

Install the mount to the fixture, tighten the mount and install the screws. Connect the fixture to the bracket and tighten the screws; connect the wires properly and put them into the junction box( Figure 18)

ADJUSTABLE FITTER MOUNTING & DIRECT MOUNTING (e=A&D)

ADJUSTABLE FITTER MOUNTING

  • Step 1 : Remove the spare parts from the A&D bracket (Figure 19)
  • Step 2 : Loosen the four bolts on the A&D bracket, connect the wires correctly, and pull the wires into the pole (Figure 20)
  • Step 3 : Place the bracket into the pole and lock the four bots (Figure 20)
  • Notice: Adjustable angle range is 0-90°(Figure 20)

EnVisinLED-AM-LED-Light-Fixture-fig \(12\)

DIRECT MOUNTING

  • Step 1 : Remove the four bolts from A&D bracket, remove the four rubber from the installation bar,put the four rubber plugs on the place where the four bolts were previously placed on the bracket for waterproofing purposes (Figure 21)
  • Step 2 : Fix the A&D bracket to the square pole with the bolt, open the cover of A&D bracket junction box,pull the wires into the bracket junction box, connect the wires properly and cover the junction box(Figure 22)
  • Notice: The adjustable angle range is 0-90°(Figure 23) Same as round pole installation, please remember to use the adapting plate for round pole installation (Figure 23)

EnVisinLED-AM-LED-Light-Fixture-fig \(13\)

Instructions for Photocell

When the photocell function is required, photocell should be installed on the back of light;
When it’s not required, a shorting cap should be installed on the back of light Standard wire: (Figure 24)
L/live wire: Black\Brown;N/null wire: White\Blue; Ground wire: Green\Yellow- green.

EnVisinLED-AM-LED-Light-Fixture-fig \(14\)

Instructions for Motion Sensor or PIR sensor(Figure 25)

  1. Unscrew the 1/2 plug;
  2. For products with motion sensor or PIR sensor function, the induction module should be installed on the socket ;

EnVisinLED-AM-LED-Light-Fixture-fig \(15\)

Special Functions Optional:

Color temperature adjustment(figure 26)

  1. Unscrew the 3/4 plug ;
  2. Adjust the switch to get the desired color temperature according to the label on the fixture;
  3. Install and tighten the 3/4 plug;

EnVisinLED-AM-LED-Light-Fixture-fig \(16\)

Wattage adjustment (figure 27)

  1. Unscrew the 3/4 ;
  2. Adjust the switch to get the desired Wattage according to the label on the fixture;
  3. Install and tighten the 3/4 plug;

EnVisinLED-AM-LED-Light-Fixture-fig \(17\)

CCT & Wattage adjustment (figure 28)

  1. Unscrew the 3/4 plug ;
  2. Adjust the integrated switch for CCT & Wattage adjustable to get the desired CCT and Wattage according to the label on the fixture;
  3. Install and tighten the 3/4 plug;

EnVisinLED-AM-LED-Light-Fixture-fig \(18\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals