HITACHI H1208 Room Air Conditioner Instruction Manual
- June 1, 2024
- Hitachi
Table of Contents
- HITACHI H1208 Room Air Conditioner
- Product Information
- FAQ
- SAFETY PRECAUTION
- Names and Functions of Each Part
- Model Name and Dimensions
- Operate Air Conditioner with Smartphone
- About Software License
- Information
- MAINTENANCE
- CLEANING OF FRONT PANEL
- Regular Inspection
- AFTER SALE SERVICE AND WARRANTY
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HITACHI H1208 Room Air Conditioner
Product Information
Specifications
- Model: RC-AGS1EA0E
- Pages: 1~26, 27~54
- Refrigerant: R32
FAQ
- Q: What should I do if I detect a burning smell while the unit is operating?
- A: Stop the operation immediately, turn off the circuit breaker, and contact your agent for assistance to prevent potential faults or fire hazards.
- Q: Can I install the unit by myself?
- A: It is recommended to consult a sales agent or qualified technician for installation to avoid water leakage, short circuits, or fire hazards.
SAFETY PRECAUTION
- Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
- Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters that, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly.
- Please observe all instructions strictly to ensure safety.
- The sign indicates the following meanings.
Make sure to connect earth line.| The sign in the figure indicates
prohibition.
---|---
Indicates the instructions that must be followed.|
- Please keep this manual after reading it.
PRECAUTIONS DURING INSTALLATION
WARNING
| ● Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
● Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
● Please use the earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of the telephone. Improper installation of the earth line may cause electric shock.
● Be sure to use the specified piping set for R32. Otherwise, this may result in broken copper pipes or faults.
● Do not use refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.
CAUTION
| ● A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
● Do not install near locations where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
● Please ensure smooth flow of water when installing the drain hose.
● Do not install the indoor unit in a machine shop or kitchen where vapour from oil or its mist flows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing the indoor unit performance and may deform and in the worst case, break the plastic parts of the indoor unit.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
| ● Should an abnormal situation arise (like a burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situations.
● Please contact your agent for maintenance. Improper self-maintenance may cause electric shock and fire.
● Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
● If the supply cord is damaged, it must be replaced by the special cord obtainable at authorized service/parts centres.
● If the air conditioner is not cool, one possible cause could be due to refrigerant leakage, so consult your dealer.
The refrigerant gas used in the air conditioner is harmless. But if refrigerant gas leaks into the room, harmful products are generated when in contact with fire from appliances such as a stove heater.
When there is refrigerant gas accumulation in the room, immediately stop the air conditioner. Open the windows for ventilation and contact your agent.
| PRECAUTIONS DURING OPERATION
|
● Avoid an extended period of direct air flow for your health.
● Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
● Do not use any conductor as fuse wire, this could cause a fatal accident.
● During thunderstorms, disconnect and turn off the circuit breaker.
● Spray cans and other combustibles should not be located within a meter of the air outlets of both indoor and outdoor units. As a spray can’s internal pressure can be increased by hot air, a rupture may result.
PRECAUTIONS DURING OPERATION
|
● The product shall be operated under the manufacturer’s specification and not for any other intended use.
● Do not attempt to operate the unit with wet hands, this could cause a fatal accident.
● When operating the unit with burning equipment, regularly ventilate the room to avoid oxygen insufficiency.
● Do not direct the cool air coming out from the air-conditioner panel to face the household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
● Please ensure that the outdoor mounting frame is always stable, firm and without defects. If not, the outdoor unit may collapse and cause danger.
● Do not splash or direct water to the body of the unit when cleaning it as this may cause a short circuit.
● Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on the heat exchanger fin and block the evaporation water flow to the drain pan. The water will drop on the tangential fan and cause water to splash out from the indoor unit.
● Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
● Turn off the circuit breaker if the unit is not to be operated for a long period.
● Do not climb on the outdoor unit or put objects on it.
● Do not put a water container (like a vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and cause a short circuit.
● Do not place plants directly under the airflow as it is bad for the plants.
● When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period, water will condense on the air deflector and drip down occasionally. This will wet your furniture. Therefore, do not operate under such conditions for a long time.
● If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating pieces of equipment, etc.), the preset room temperature cannot be achieved.
● This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
Operation Range
Operation mode | Cooling/Dehumidifying | Heating |
---|---|---|
Outdoor temperature | -10 to 46°C | -15 to 21°C |
Names and Functions of Each Part
Indoor Unit
Model Name and Dimensions
MODEL | WIDTH (mm) | HEIGHT (mm) | DEPTH (mm) |
---|---|---|---|
RAK-VJ50PHAT RAK-VJ60PHAT RAK-VJ70PHAT |
1050
|
294
|
255
Indoor Unit Indications
If the power stays on and the unit is not operated, power is slightly consumed in the control circuit. The power is saved by turning off the power switch (or the circuit breaker when the power is supplied from the outdoor unit).
Attaching the air-purifying filters (Accessories) to the filter frame
- Attach the air purifying filters to the C-case to the designated position.
- The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying filters are used.
- The air purifying fi lters are not washable. It is recommended to use a vacuum to clean.
- It can be used for 1 year. When you want to renew it, please ask your sales agent.
This controls the operation function and timer setting of the room air conditioner. The range of control is about 7 meters. lf indoor lighting is controlled electronically, the range of control may be shorter.
Signal Transmission
Backlight function
- The backlight is to see the LCD readings in the dark.
- On Pressing any key, the LCD panel lights up for a period of approx. 10 seconds. After approx. 10 seconds the light automatically switches off.
- The function is independent of all other functions of the air conditioner.
- The backlight colour is white.
Precautions for Use
- Do not put the remote controller under direct sunlight and high temperature.
- Do not drop it on the floor, and protect it from water.
- If you press the Mode Selector button during operation, the air conditioner may stop for about 3 minutes for protection before you can start it again.
Operate Air Conditioner with Smartphone
Built-in iCloud Home module
iCloud Home is a cloud-based solution for remotely controlling your Hitachi air conditioning system via smartphone. You can operate the air conditioner from outside the home with your smartphone and check the operating status.
What You Should Confi rm When Using the Service
Internet environment at home
- In order to use the service, FTTH (optical fi ber) ADSL / CATV (cable TV) and other Internet services, a broadband line capable of communication is required. Not available on dial-up lines.
- For details on Internet connection, contact your provider or carrier. Please check your contract.
- Internet communication charges are the responsibility of the customer.
Smartphone
- iOS (iPhone, etc.) 10.0 / Android 8.0 or later (as of December 2021).
- To confi rm the OS version, check on your smartphone, or contact your smartphone manufacturer.
- Make sure that you can connect to the router with wireless LAN.
- Tablets are not guaranteed to work.
Wireless LAN router (Hereinafter router)
- Please use a router that supports the 2.4GHz band.
- For security, be sure to use a router that can set the encryption method WPA2 or WPA (either TKIP or AES). We recommend the WPA2 (AES) encryption method. For the setting procedure, refer to the instruction manual of the router.
- Routers that support only WEP cannot be used.
- Mobile routers are not guaranteed to work.
Initial Settings
Please install the airCloud Home app on your smartphone
- Search for the airCloud Home app
- For Android models: Open Google Play. Android is a trademark and registered trademark of Google LLC.
- For iOS models (iPhone): Open the App Store. iPhone is a trademark and registered trademark of Apple Inc.
- Please install it according to the screen
- In order to use the dedicated app, you need to read and agree to the Terms of Service.
- To a dedicated application is free of charge, but to download the application, the data charges as per the internet provider or smartphone network provider charges apply.
- The names and icons of the dedicated apps are as of September 2021. It may be changed by updating the application.
Notes
- The fi rst registered user becomes a group administrator by default and manages other users and also set access rights for other users.
- When using with multiple users, the registered user should invite other users to register.
Notes on Wireless LAN
WARNING
- Do not enable remote features near those with a cardiac pacemaker or defi brillator If it is too close, radio waves may affect the operation of pacemakers and other devices.
Use frequency band
In the frequency band used by this air conditioner, in addition to industrial, scientific c and medical equipment such as microwave ovens, private radio stations for identifi cation of mobile objects (radio stations that require a license) and special Low power radio stations (radio stations that do not require a license) and amateur radio stations (radio stations that require a license) are in operation.
- Before using this air conditioner, make sure that local radio stations for identification of mobile objects, specifi ed low-power radio stations and amateur radio stations are not operating nearby.
- If any harmful radio interference occurs from the air conditioner to the mobile station identifi cation radio station, immediately stop using the radio wave and contact below to consult about measures for avoidance.
- In addition, if you have any problems such as harmful radio interference from the air conditioner to the specifi ed low power radio station for identifying the moving object or amateur radio station. Please contact us.
How to use frequency
Equipment certification
This air conditioner has a built-in wireless device that has been approved for construction design based on the Radio Law, so a license for a wireless station is not required. However, the following acts are prohibited by the Radio Law.
- Disassemble / modify the wireless device.
- Remove the main unit nameplate.
- Erase the indication on the nameplate of the main unit.
Security measures
- Since wireless LAN transmits and receives using radio waves, there is a risk of unauthorized access. Please take security measures for the wireless LAN router (hereinafter, router) to ensure data security. Please note that we do not take any responsibility if a problem occurs without implementing security measures.
- We recommend that you set a password (encryption key) for the router of at least 8 characters and no more than 63 characters. (Refer to the instruction manual of the router for the limitation of the number of characters.) When you change the password (encryption key), change the setting according to “When the router is replaced” in the iCloud Home app.
About firmware
- This air conditioner has the function of connecting to our server through the Internet and automatically updating its firmware to the latest version. During the update, wireless communication may be interrupted and communication may be interrupted or can be slow.
- Do not analyze or modify the firmware.
- Do not connect to wireless networks for which you do not have usage rights. Unauthorized wireless networks (*SSID) that you do not have permission to use may be displayed during automatic search of the wireless network environment.
- SSID is a name to identify a specific network in wireless LAN. If this SSID matches on both devices, communication is possible.
- Do not use where magnetic fields, static electricity or radio interference may occur.
- If used near the following devices, communication may be interrupted or the speed may decrease. Please use as far as possible.
- Microwave oven during cooking
- Bluetooth compatible device
- Other wireless LAN devices (wireless WEB cameras, PC devices, etc.) except the router (wireless LAN router) that communicates with this air conditioner.
- If the air conditioner is surrounded by a metal object, or if there is an object such as metal or reinforced concrete that cannot pass radio waves between itself and the router, it may not be able to communicate due to the reception of radio noise or a short range.
Information about Using Wireless LAN
- The air conditioner can be operated from a place that is not directly visible. Therefore, for example, a situation may occur where a person in the room turns ON while another person turns OFF from outside. Especially when infants, children, the elderly, the sick, or the physically handicapped are indoors, use it when a person who can manage it is nearby. In addition, before using, please understand the condition of the room before operating.
- Your smartphone and air conditioner communicate data via our server using the Internet. Therefore, due to the condition of the communication line of your mobile phone company or provider, the setting of your router, or the stop of service due to maintenance of the airCloudHome server, data communication may not be possible, and the system may not or delay operate.
- After connecting the air conditioner to the router, you can perform data communication. To use, you will incur the broadband internet charges and your smartphone network provider charges as per the customer contract.
- If the air conditioner is not operated for a long time or if the home internet network has been completely shut down, it is advisable to initialize the airCloud Home module and reconnect the same.
- Please do not inform other people about the SSID / KEY of this air conditioner.
- Our company guarantees repair of this air conditioner under certain conditions. However, we do not guarantee that stored data is lost or damaged.
- This air conditioner stores network setting information. When disposing of this air conditioner, initialize the built-in airCloud Home module (Refer to page 11 Restore Factory Setting).
- Customers are responsible for resolving any defi ciencies in the Internet and wireless environment at home.
- If you operate the air conditioner using the App, some of the set functions may be canceled. Check the web page for details.
SSID & KEY Label Paste
SSID & KEY label details of Air conditioner’s built-in airCloud Home module is pasted here for your reference. Please keep it safe for future requirements during pairing process and please write down the installation location (like living room, bed room, etc.) on the label. The AC type is “2” that is for models with a built-in airCloud Home module.
About Software License
The software installed in this air conditioner is composed of multiple
independent software modules, and each software module has the copyright of
Johnson Controls Air Conditioning (Herein after referred to as “the Company”)
and a third party. This air conditioner also contains software modules
developed or created by us, but these software and accompanying documents have
proprietary rights and intellectual property rights of our company. These are
protected by copyright law and other laws.
Initial Setting of App
Installation of App
Go to Google Play or the Apple Store (depending on your smartphone) and download the “airCloud Home” Application
- Please read and agree to “the Terms of Use” on the App.
- The App is free. Communication charges will be incurred for download and operation as per the local cell phone provider.
- Android is a trademark and registered by Google LLC.
- iPhone is a trademark and registered by Apple Inc.
- QR code is a trademark and registered by DENSO WAVE Inc.
Registration on App
- Click “Create Account”.
- Enter your name and click “Continue”.
- Enter your mobile number and password (or click “E-mail” tab, and enter your E-mail address and password), read the “terms and conditions” and check on the box, click “Continue”.
- Enter received verifi cation code you received and click “Continue”.
- Click “Auto-Detect My Location” or Enter address details manually, and click “Finish”.
- The account has been created successfully.
Note
The first registered user can manage all the users and set access rights as a
group owner. Group owner can invite others to register.
Air Conditioner Registration and Router Connection
Make sure that the air conditioner is plugged in, then follow the steps below to add your air conditioner device to the App.
- Click “Add Air Conditioner” on the top screen after registration and login your App.
- Scan QR code on the bundled SSID & KEY label in this user manual or by lifting the front panel of your air conditioner.
- If the SSID shown on the App is your home router, enter your home router password, click “Next”. Otherwise, click “Change Wi-Fi Network”, select your home router enter password and click “Next”,
- Switch ON your air conditioner now. Once your air conditioner is switched on, or reset the internal settings (restore the factory settings) by remote control, it will automatically set into pairing mode for 10 minutes. Wi-Fi LED on air conditioner’s panel (see diagram in status indicator section) will blink for 3 times repeatedly showing air conditioner is in pairing mode. Wi-Fi LED keeps blinking till communication with Wi-Fi router is succeeded. When the airCloud Home module reset operation is performed through the remote control, the pairing mode can be entered without restarting the air conditioner.
- Click “Change Wi-Fi Network”, select the Wi-Fi access point of the Built-in airCloud Home module with SSID printed on the bundled SSID&KEY Label, input password (the KEY). Click right arrow icon on the screen top to continue for connecting your smart phone with the Adapter.
- Waiting for the built-in airCloud Home module to connect to your home router. When communication is established, Wi-Fi LED on panel will be continuously ON after blinking.
- Waiting for the Smartphone to connect with your home network. If your Smartphone is connected to another wireless network then click on Change Wireless Network & select home network.
- Please assign a name to your registered air conditioner. If you assign a custom name to your air conditioner, it will not be compatible with your smart speaker (integrated with Alexa or Google Assistant), so we recommend that you select a name from the pre-defined list.
- Your air conditioner has been successfully confi gured.
- If communication cannot succeed within 10 minutes, please follow the instructions of the App to complete the pairing process again.
- If a user in the group has already registered some air conditioning units, the other users in the same group can also control the unit.
- If the air conditioning is not confi gured with router, at power on unit enters into pairing mode every time for 10 minutes with Wi-Fi indication blinking for 3 times.
- If the air conditioning is already confi gured with router, and router detection is available then at power on, unit will skip the pairing mode & try to connect to router.
- Please enter the SSID name of the air-conditioner to proceed with the pairing process if unable to scan QR code.
Initialization of the Built-in airCloud Home Module
Reset the internal settings (restore the factory settings) by remote controller. Please note that the confi guration will be cleared and pairing procedure will be required to do again to use the built-in airCloud Home module.
- Press Mode key and ON Timer key simultaneously, pointing the remote controller towards the air conditioning unit.
- Make sure Wi-Fi LED on Indoor Unit fl ashes 4 times repeatedly for about 20 seconds (LED is turning off between 2 sequences of 20 seconds).
- Restart the unit (turn power OFF during 1 minute, then turn power ON again) and check that the Wi-Fi LED is blinking 3 times.
If Wi-Fi LED is indeed fl ashing 3 times, pairing mode is well activated and factory settings have well been restored.
Status Indicator (LED Indicator may light up while the air conditioner is turned off)
Wi-Fi Lamp | Corresponding Status |
---|
LED OFF
| ● Pairing time out occurs (after 10 mins.) & configured router not detected.
● Air conditioner is not plugged in.
● Built-in airCloud Home module and the air conditioner is not connected.
LED ON
| ● The connection between the Built-in airCloud Home module and the router is completed.
● The operation can be conducted through smartphone.
LED flashes 3 times| Waiting to connect to the Wi-Fi router using AP mode.
LED flashes 4 times| Restoring factory setting procedure has started.
LED flashes 5 times| Communication error between air conditioner & Built-in
airCloud Home module
(Error detection time: approx 24 mins.)
LED flashes with 4 sec ON/ 1 sec OFF|
Router connection error.
LED flashes with 4 sec ON/ 3 sec OFF| Cloud connection error. (Error detection time: approx 30 mins.)
Indoor Unit Indications: Wi-Fi LED
Note:
- Please try to power OFF/ON your air conditioner from mains switch when an error occurs.
- Wi-Fi is a trademark or registered trademark of the “Wi-Fi” Alliance”.
Information
Capabilities
Heating Capability
CAUTION: Do not use a stove or any other high temperature devices in proximity to the indoor unit.
- This room air conditioner utilizes a heat pump system that absorbs exterior heat and brings it into a room to be heated. As the ambient temperature gets lower, heating capability will also lower. In such a situation, the inverter work to increase compressor rpm to keep the unit’s heating capability from decreasing. If the unit’s heating performance is still unsatisfactory, other heating appliances should be used to augment this unit’s performance.
- The air conditioner is designed to heat an entire room so that it may take some time before you feel warm. Timer operation is recommended for effective preheating ahead of the desired time.
Cooling and Dehumidifying Capabilities
- If the heat present in a room exceeds the unit’s cooling capacity (for example, if there are many people in the room or other heating appliances are used), the preset room temperature may not be reached.
Refrigerant Information
- For the refrigerant charge information, please refer to the outdoor unit installation manual or specifi cation label.
MAINTENANCE
CAUTION: Cleaning and maintenance must be carried out only by qualifi ed service personnel. Before cleaning, stop operation and switch off the power supply.
PRE-FILTER
Clean the Pre-filter, as it removes dust inside the room. In case the Pre- filter is full of dust, the air flow will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the Pre-filter following the procedure below.
PROCEDURE
- Open the front panel and remove the Pre-filter
- Gently lift and remove the air purifying filters from the air purifying filter frame.
- Vacuum dust from the Pre-filter and air purifying fi lter using vacuum cleaner. If there is too much dust, rinse under running tap water and gently brush it with soft bristle brush. Allow filters to dry in shade.
- Re-insert the air purifying filter to the filter frame. Set the Pre-filter with “FRONT” mark facing front, and slot them into the original state.
- After attaching the Pre-filters, push the front panel at three arrow portions as shown in figure and close it.
NOTE
Air purifying filter should be cleaned every month or sooner if noticeable loading occurs. When used overtime, it may lose its deodorizing function. For maximum performance, it is recommended to replace it every 1 year depending on application requirements.
CAUTION
- Do not operate the air conditioner without Pre-fi lter. Dust may enter the air conditioner and fault may occur.
CLEANING OF FRONT PANEL
- Remove the front panel and wash with clean water.
- Wash it with a soft sponge.
- After using neutral detergent, wash thoroughly with clean water.
- When front panel is not removed, wipe it with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
- Wipe the water thoroughly.
- If water remains at indicators or signal receiver of indoor unit, it causes trouble.
- Method of removing the front panel. Be sure to hold the front panel with both hands to detach and attach it.
- When the front panel is fully opened with both hands, push the right arm to the outside to release it, and while closing the front panel slightly, pull it out forward.
- Move the projections of the left and right arms into the Flanges in the unit and securely insert them into the holes.
CAUTION
Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a brush,
because they will damage the plastic surface and the coating.
Regular Inspection
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONNEL EITHER EVERY HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.
AFTER SALE SERVICE AND WARRANTY
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS
FrostWash Operation
FrostWash Operation does not start
| Is the total operation time of the air conditioner beyond default setting
when the air-conditioner is operated for about 30 minutes and stopped?
---|---
The FrostWash be started that must to meet with the follow conditions.
Does not change to non-automatic “FrostWash”?
Does it happen after “sleep” and “time off”? Automatic “FrostWash” interval
becomes longer. Please operate manual “FrostWash”
with remote controller.
Within 60 minutes after the end of “FrostWash”, “FrostWash” is not operated
for product protection.
Noise occurred during FrostWash operation| It is the sound that the internal
machine is inflated and contracted by the temperature change and the fin of
the heat exchanger is frozen and thawed
(Clean Function Lamp) blinks
| Repeat for 1 second on and 1 second off for 10 seconds
Because “FrostWash” can not work when operating the “FrostWash” with remote controller.
● The air conditioner is operating
● Outside air temperature, room temperature and room humidity are not suitable for “FrostWash”
● It has not been over 60 minutes since the end of “FrostWash”
Repeat for 4 seconds on and 1 second off for 15 seconds
Because FrostWash has not been done for a long time.
Operate the remote controller to operate “FrostWash”.
Mold Guard Operation
Mold Guard operation does not start
| If the air conditioner operation is stopped after heating operation, Mold Guard will not operate. If the air conditioner has operated in cooling and drying mode, including auto mode, for less than 10 minutes, the Mold Guard operation will not start even if the air conditioner is in off mode. If operation of the air conditioner is stop by OFF Timer or GoodSleep Timer, the Mold Guard will not operate.
If ON Timer is set and on time is within about 2 hours, the Mold-Guard will not operate.
---|---
During Mold Guard
| (Clean Function Lamp) on the indoor unit lights up during Mold Guard
operation. If Mold Guard operation stop at middle point, FrostWash and Filter
sign indicator will turn off.
Notes| The horizontal deflector remain open. Room temperature or humidity may
rise.
Depending on situation, Mold Guard will operate with Fan Mode.
When there would be the window near indoor unit, the water might condense on the window during Mold Guard. If necessary, to cancel Mold Guard.
When after FrostWash operation, the water inside the indoor unit evaporates and depending on the room conditions, may emitted as steam. But this is not a malfunction. If necessary, to cancel Mold-Guard.
- The following phenomena do not indicate unit failure.
During heating, the operation indicator blinks and air blow stops| <Operation start>
The unit is preparing to blow warm air. Please wait.
The outdoor unit is defrosting. Please wait.
---|---
Hissing or fizzy sounds
| Refrigerant flow noise in the pipe or valve sound generated when flow rate
is adjusted.
Refrigerant flow noise occur during changes of maximum fan speed to lowest
speed.
Squeaking noise| Noise generated when the unit expands or contracts due to
temperature changes.
Rustling noise
| Noise generated with the indoor unit fan’s rpm changing such as operation start times.
Clicking noise
| Noise of the motorized valve when the unit is switched on.
Perking noise
| Noise of the ventilation fan sucking in air present in the drain hose and blowing out dehumidifying water that had accumulated in the condensed water collector. For details, consult your sales agent.
Changing operation noise
| Operation noise changes due to power variations according to room temperature changes.
Mist emission
| Mist is generated as the air within the room is suddenly cooled by
conditioned air.
Steam emitted from the outdoor unit| Water generated during defrosting
operation evaporates and steam is emitted.
Odors
| Caused as the smells and particles of smoke, food, cosmetics, etc. present
in room air become attached the unit and blown off into the room again.
The outdoor unit continues to operate even if operation is stopped.|
Defrosting is underway (as the heating operation is stopped, the microcomputer
checks frost accumulated in the outdoor unit and instructs the unit to perform
automatic defrosting if necessary).
---|---
The OPERATION
lamp is flashing
| Shows preheating or defrosting operation is underway. As the protective circuit or preheat sensor operates when unit operation is stopped during preheating and then restarted, or when operation mode is switched from cooling to heating, the lamp continues to blink.
Does not reach the temperature setting
| Actual room temperature may deviate slightly from the remote controller’s temperature setting depending on the number of people in the room, indoor or outdoor conditions.
If the unit still fails to operate normally after performing the above inspections, turn the circuit breaker off and contact your sales agent immediately.
Contact your sales agent immediately if the following phenomena should occur
- The circuit breaker switches off or the fuse blows frequently.
- The switch operation is not stable.
- Foreign matter or water accidentally enters the unit interior.
- The power cord gets excessively hot or its insulation is torn or stripped.
- TIMER lamp on the indoor unit display blinks. (As the nature of the failure can be identifi ed by the blinking cycle, check the blinking cycle before turning off the circuit breaker.)
Notes
- IIn quiet or stop operation, the following phenomena may occassionally occur, but they are not abnormal for the operation.
- Slight fl owing noise of refrigerant in the refrigerating cycle.
- Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops.
- The odor will possibly be emitted from the room air conditioner because the various odor, emitted by smoke, foodstuffs, cosmetics and so on, sticks to it. So the pre-fi lter and the evaporator regularly must be cleaned to reduce the odor.
- Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections. Inform your agent of the model of your unit, production number, date of installation. Please also inform him regarding the fault.
Please note
On switching on the equipment, particularly when the room light is dimmed, a
slight brightness fluctuation may occur. This is of no consequence.
The conditions of the local Power Supply Companies are to be observed.
CONTACT
- Access the full version of the User Operation Manual by scanning the code.
- More languages available.
- https://docs.hitachiaircon.com/RAK-VJ-PHAT-RAC-VJ-PHAT
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>