GEBERIT Urinal System Southern Africa Instruction Manual
- June 1, 2024
- GEBERIT
Table of Contents
GEBERIT Urinal System Southern Africa
Safety
About this document
This document is intended for operators ofGeberit Selva, Preda and Tamina
urinals with integrated flush control, battery or generator operation.
This document applies for the models of these urinals with Bluetooth®
interface. The specification plate of these urinals are labelled with
“IRUR-15-A” and the Geberit Connect logo.
Intended use
Urinals allow for urinating while standing up. These urinals are designed to
be operated using a flush. Use for any other purpose is deemed improper.
Alert levels and symbols in this manual
Alert levels and symbols
ATTENTION
Indicates a hazard which, if not avoided, can lead to material
damage.
Refers to important information.
Safety notes
- Operation, care and maintenance may only be performed by the operator as described in this operation manual.
- Repairs, conversions and additional installations may only be carried out by trained experts in sanitation applications.
- Only trained experts in sanitation applications may replace currentcarrying parts.
- Only Geberit spare parts may be used.
Product description
Structure
Figure 1: Geberit Selva, Preda and Tamina urinals with integrated flush control, battery operation or self-sustaining
- Spray head
- Urinal ceramic appliance
- Urinal trap
- Water pressure reducing valve
- Solenoid valve with basket filter
- Generator (only for self-sustaining power supply)
- Urinal flush control with a battery or self-sustaining power supply
- IR sensor
Technical data
Battery operation1) | Generator operation2) | |
---|---|---|
Operating voltage | 3 V DC | 6.6 V DC |
Battery type | Alkaline battery (1.5 V |
AA)
| –
Power consumption| < 0.5 W
Power consumption standby| < 0.1 W
Flow pressure range| 100-800 kPa
1-8 bar
Ambient temperature| 5–40 °C
Storage temperature| -20 – +70 °C
Flow rate at 1 bar with flow limiter| 0.18 l/s
Flush time, factory setting| 7 s
Flush time, adjustment range| 1-15 s
Wireless technology| Bluetooth® Low Energy3)
Frequency range| 2400–2483.5 MHz
Maximum output power| 4 dBm
- Battery service life: approx. 2 years
- When used at least 30 times per day on average for a flush time of 7 s each, the urinal works in a self-sustaining manner.
- The Bluetooth® brand and its logos are the property of Bluetooth SIG, Inc. and are used under license by Geberit.
Simplified EU Declaration of Conformity
Geberit International AG hereby declares that the radio equipment type for
Geberit Preda,Selva and Tamina urinals with integrated flush control, mains,
battery or generator operation complies with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following Internet address: https://doc.geberit.com/970892000.pdf
Retrofitting to flush operation
Geberit Selva, Preda and Tamina urinals for integrated flush control (art. no.
116.075.00.1,116.085.00.1 and 116.142.00.1) are supplied without a urinal
flush control. It is possible to retrofit the urinals to flush operation by
installing a urinal flush control.
Installation of the urinal flush control is described in the following
documents:
- Installation manual for Geberit Selva urinals (art. no. 970.645.00.0)
- Installation manual for Geberit Preda urinals (art. no. 970.644.00.0)
- Installation manual for Geberit Tamina urinals (art. no. 970.646.00.0)
Operation
Geberit Apps
Various Geberit apps are available for operation, settings and maintenance.
The apps communicate with the device via a Bluetooth® interface.
The Geberit apps are available free of charge for Android and iOS smartphones
in the respective App Stores.
Establishing connection with device
- Scan the QR code and follow the instructions on the landing page.
Actuating the flush
The electronic flush actuation has infrared leg detection. The leg detection
range starts approx. 50 cm in front of the urinal.
- Enter the detection range and remain there for at least 10 seconds.
- Leave the detection range.
The flush will actuate.
For testing purposes, the flush can also be actuated with a Geberit app.
Troubleshooting
Malfunction | Cause | Action |
---|
Incorrect flushes (too soon, too late, unwanted)
| ****
Detection distance not set correctly
| ▶ Optimise the detection distance. → See “Optimising the detection
distance”, page 20.
IR window is dirty or
wet
| ▶ Clean or dry the IR window.
IR window scratched| ▶ Contact a skilled person.
Water is running continuously into the urinal ceramic.
| ****
Software fault
| ▶ Restart the urinal flush control. → See “Restarting the urinal flush control”,
page 21.
Technical fault| ▶ Contact a skilled person.
Flushing out of the urinal ceramic is inadequate.| Flush time set incor-
rectly| ▶ Set flush time. → See “Setting the flush time”,
page 20.
Flush volume is inadequate.| Basket filter in solenoid valve
clogged
| ▶ Clean the basket filter. → See “Cleaning or replacing
the basket filter”, page 20.
Battery warning level 1
(4 short signal tones upon entering
the detection range)
| Batteries dead Rechargeable battery empty| ▶ Replace the batteries. → See “Replacing the batteries”, page 20.
▶ Charge the rechargeable battery of the self-sustaining power supply. → See “Charging the rechargeable battery of the self-sustaining
power supply”, page 21.
Battery warning level 2
(no flush actuation, 2 short signal
tones every 30 seconds)
Battery warning level 3
(no flush actuation, no signal tone)
Maintenance
Structure of Maintenance chapter
The accompanying illustration sequences must be followed while carrying out
the instructions provided in this chapter. Each set of instructions refers to
the accompanying illustration sequence.
Caring for and cleaning smooth surfaces
All smooth surfaces can be cleaned hygienically with water and a mild, liquid
cleaning agent that is kind to the skin.
ATTENTION
Surface damage caused by aggressive and scouring cleaning agents
- Never use cleaning agents that contain chlorine or which are acidic, abrasive or corrosive.
Activating cleaning mode
To clean the urinal ceramic and to clean or replace the urinal trap, the flush
actuation can be suppressed for a few minutes.
- Activate cleaning mode with the Geberit app, Geberit Service Handy or Geberit Clean Handy.
Result
- The flush actuation is suppressed for 10 minutes.
- Once these 10 minutes have elapsed, a flush is actuated.
Notes:
- You can only activate cleaning mode 30 minutes after activating the power supply or setting the flush time.
- The cleaning time of 10 minutes can be changed with a Geberit app (1–20 minutes).
Cleaning or replacing the spray head
- Clean the cover for the spray head and the nozzle with a mild, liquid cleaning agent at least once a year.
- Descale the nozzle with a commercially available descaling agent if necessary.
- Replace the nozzle if it can no longer be completely cleaned and descaled.
Prerequisite
Refer to figure sequence 3 , page 300 while carrying out the instructions.
- Demount the urinal flush control to disconnect the water supply. → See figure sequence 1 , page 298.
- Demount the cover for the spray head.
- Demount the nozzle.
- Clean the nozzle and rinse with water, or replace the nozzle (art. no. 243.333.00.1).
- Mount the nozzle.
- Mount the cover for the spray head.
- Mount the urinal flush control. → See figure sequence 2 , page 299.
Result
- The urinal is ready for operation.
Replacing the urinal trap
For hygiene reasons, replace the urinal trap at least once a year.
Prerequisite
- Cleaning mode is activated.
- Refer to figure sequence 4 , page 301 while carrying out the instructions.
- Demount the cover for the urinal trap.
- Demount the urinal trap.
- Replace the urinal trap (art. no. 243.312.00.1) and the cover for the urinal trap (art. no. 243.314.00.1).
- Mount the urinal trap.
- Mount the cover for the urinal trap.
Cleaning or replacing the basket filter
- Clean the basket filter in the solenoid valve at least every 2 years or if the flush volume decreases.
- Descale the basket filter with a commercially available descaling agent if necessary.
- Replace the basket filter if it can no longer be completely cleaned and descaled.
Prerequisite
Refer to figure sequence 5 , page 302 while carrying out the instructions.
-
Demount the urinal flush control. → See figure sequence 1 , page 298.
-
Disconnect the cable for the battery or rechargeable battery compartment. → See figure sequence 6 , page 303.
-
Demount the securing clamp.
-
Disconnect the solenoid valve and demount the coupling.
-
Remove the basket filter.
-
Clean, descale or replace the basket filter.
-
Install the basket filter.
-
Mount the coupling and snap in the solenoid valve.
-
Mount the securing clamp.
-
Plug in the cable for the battery or rechargeable battery compartment.
→ See figure sequence 7 , page 303. -
Mount the urinal flush control. → See figure sequence 2 , page 299.
Result
- The urinal is ready for operation.
Setting the flush time
The flush time can be adjusted to suit the user’s needs using a Geberit app.
Optimising the detection distance
If flushes are actuated too soon, too late or unintentionally, you can
optimise the detection distance of the IR sensor with a Geberit app.
Replacing the batteries
Prerequisite
- Refer to figure sequence 8 , page 304 while carrying out the instructions.
- 2 replacement batteries (alkaline batteries, 1.5 V, AA) are available.
- Demount the urinal flush control. → See figure sequence 1 , page 298.
- Disconnect the battery compartment cable. → See figure sequence 6 , page 303.
- Remove the battery compartment.
- Open the cover, remove the batteries and dispose of them.
- Insert the replacement batteries.
- Insert the battery compartment.
- Plug in the battery compartment cable. → See figure sequence 7 , page 303.
- Mount the urinal flush control. → See figure sequence 2 , page 299.
Result
- The urinal is ready for operation.
Charging the rechargeable battery of the self-sustaining power supply
If Geberit urinals with generator operation are not used very often, the rechargeable battery will not charge sufficiently. If a signal tone sounds when you enter the detection range, this indicates that the rechargeable battery is almost empty. → See “Troubleshooting”, page 18.
- Demount the urinal flush control. → See figure sequence 1 , page 298.
- Disconnect the cable for the battery or rechargeable battery compartment. → See figure sequence 6 , page 303.
- Test and charge the rechargeable battery with the battery charger (art. no. 116.452.00.1). → See user manual 965.861.00.0.
- Plug in the cable for the battery or rechargeable battery compartment. → See figure sequence 7 , page 303.
- Mount the urinal flush control. → See figure sequence 2 , page 299.
Result
- The urinal is ready for operation.
Restarting the urinal flush control
- Demount the urinal flush control. → See figure sequence 1 , page 298.
- Disconnect the cable for the battery or rechargeable battery compartment. → See figure sequence 6 , page 303.
- Plug in the cable for the battery or rechargeable battery compartment. → See figure sequence 7 ,page 303.
- Mount the urinal flush control. → See figure sequence 2 , page 299.
Result
- The urinal flush control restarts.
Disposal
Constituents
This product meets the requirements of Directive 2011/65/EU (RoHS)
(restriction of the use of certain hazardous substances in electrical and
electronic equipment).
Disposal of waste electrical and electronic equipment
The symbol of the crossed-out wheeled bin means that waste electrical and
electronic equipment (WEEE) must be disposed of separately and not with other
non-recyclable waste.
End users are legally obliged to return old equipment to public waste disposal
authorities,distributors, or Geberit for proper disposal. Many distributors of
electrical and electronic equipment are obliged to take back WEEE free of
charge. Contact the responsible sales or service company to return the WEEE to
Geberit.
Used batteries and accumulators that are not enclosed within the old equipment, as well as lamps that can be removed from the old equipment in a non-destructive manner, must be separated from the old equipment before being handed over to a disposal point.
If personal data is stored on the old equipment, end users themselves are responsible for deleting it before handing it over to a disposal point.
Geberit International AG
Schachenstrasse 77, CH-8645 Jona
documentation@geberit.com
www.geberit.com
54043198642348811 © 02-2022
970.648.00.0(01)